Because of their low impact on environment, PV/wind hybrid systems which use fuel cells (FCs) as the energy storage
device are one of the most promising renewable energy sources. In such systems, optimum configuration (sizing) plays an
important role for decreasing the system cost. In this paper, PV/wind/FC system is modeled and a hybrid metaheuristic
technique based on chaotic search (CS), harmony search (HS) and simulated annealing (SA) is employed to find the
optimum configuration. Optimum configuration is found for PV/FC, wind/FC, and PV/wind/FC systems and the results
are compared.