BibTex RIS Kaynak Göster

The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change

Yıl 2003, Cilt: 6 Sayı: 1, 31 - 39, 01.03.2003

Öz

Compressor and refrigerant play key roles in a refrigeration system. Owing to the de-mands of environment protection, the CFCs and HCFCs refrigerants will be phased out in a short time, and new refrigerants such as R600, R134a and R407C will be used. As the new refrigerant is selected, the motion regularity of the valves will be changed. The motion regularity of the ring valves of a 2-stage refrigerating piston compressor is simulated, and the calculations are done respectively with refrigerants R717 (ammonia), R22 and R134a. The results show that refrigerants and working conditions of a compressor have a direct effect on the motion of the ring valves. Comparing the original design parameters of the ring valves with the modified ones, the former are effective for the HCFC refrigerants, the latter have perfect motion of the valves for the new refrigerants, and the refrigeration system performance parameters, such as input power, the refrigerating quantity and the COP value, are also better. Service life test of the compressor system using the ring valves has been done for R717. The compressor using the modified ring valves has a life exceeding 8000 hours. Hence, the valve design should consider the influences of the refrigerant.

Yıl 2003, Cilt: 6 Sayı: 1, 31 - 39, 01.03.2003

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Regular Original Research Article
Yazarlar

Zhao Yuanyang Bu kişi benim

Li Liansheng Bu kişi benim

Guo Bei Bu kişi benim

Shu Pengcheng Bu kişi benim

Yayımlanma Tarihi 1 Mart 2003
Yayımlandığı Sayı Yıl 2003 Cilt: 6 Sayı: 1

Kaynak Göster

APA Yuanyang, Z., Liansheng, L., Bei, G., Pengcheng, S. (2003). The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change. International Journal of Thermodynamics, 6(1), 31-39.
AMA Yuanyang Z, Liansheng L, Bei G, Pengcheng S. The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change. International Journal of Thermodynamics. Mart 2003;6(1):31-39.
Chicago Yuanyang, Zhao, Li Liansheng, Guo Bei, ve Shu Pengcheng. “The Modification of the Valves of a Refrigeration Piston Compressor Due to the Refrigerant Change”. International Journal of Thermodynamics 6, sy. 1 (Mart 2003): 31-39.
EndNote Yuanyang Z, Liansheng L, Bei G, Pengcheng S (01 Mart 2003) The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change. International Journal of Thermodynamics 6 1 31–39.
IEEE Z. Yuanyang, L. Liansheng, G. Bei, ve S. Pengcheng, “The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change”, International Journal of Thermodynamics, c. 6, sy. 1, ss. 31–39, 2003.
ISNAD Yuanyang, Zhao vd. “The Modification of the Valves of a Refrigeration Piston Compressor Due to the Refrigerant Change”. International Journal of Thermodynamics 6/1 (Mart 2003), 31-39.
JAMA Yuanyang Z, Liansheng L, Bei G, Pengcheng S. The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change. International Journal of Thermodynamics. 2003;6:31–39.
MLA Yuanyang, Zhao vd. “The Modification of the Valves of a Refrigeration Piston Compressor Due to the Refrigerant Change”. International Journal of Thermodynamics, c. 6, sy. 1, 2003, ss. 31-39.
Vancouver Yuanyang Z, Liansheng L, Bei G, Pengcheng S. The Modification of the Valves of a Refrigeration Piston Compressor due to the Refrigerant Change. International Journal of Thermodynamics. 2003;6(1):31-9.