Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2018, Cilt: 2 Sayı: 3, 223 - 228, 15.12.2018

Öz

Kaynakça

  • 1. Saiidi, M., and M.A. Sozen, Simple nonlinear seismic analysis of R/C structures. Journal of Structural Engineering, 1981. 107: 937-952.
  • 2. Iwan, W.D., Drift spectrum: measure of demand for earthquake ground motions. Journal of Structural Engineering, 1997. 123: 397–404.
  • 3. Tekeli, H., A. Tüken, M. Türkmen, and A. Atımtay, Depreme Maruz Yapının Ötelenmesinin Basit Hesabı: Kapalı Çözüm. Antalya Yöresinin İnşaat Mühendisliği Sorunları Kongresi: Antalya, 2005. Vol:1, p 190-203. (in Turkish)
  • 4. Tekeli, H., F. Demir, and E. Atımtay, Çerçeveli ve Perdeli-Çerçeveli Betonarme Binaların Ötelenmesi: Analitik Çözümler, Journal of the Faculty of Engineering and Architecture of Gazi University, 2008. Vol: 23, No 1, 9-19. (in Turkish)
  • 5. Lu, Y., X. Gu, and J. Wei, Prediction of seismic drifts in multi-storey frames with a new storey capacity factor. Engineering Structures, 2009. 31;345-357.
  • 6. TEC. Deprem Bölgelerinde Yapılacak Binalar Hakkında Esaslar, The Ministry of Public Works and Settlement, 2007, Ankara. (in Turkish)
  • 7. Sindel, Z., R. Akbaş, and S.S. Tezcan, Drift control and damage in tall buildings. Engineering Structures, 1996 18: 957-966.
  • 8. TEC. Türkiye Bina ve Deprem Yönetmeliği (Draft), T.C. Disaster and Emergency Management Presidency, 2016, Ankara. (in Turkish)

Investigation on limitation of reduced relative storey drifts according to TEC 2007

Yıl 2018, Cilt: 2 Sayı: 3, 223 - 228, 15.12.2018

Öz

During the earthquake motion,
limitation of storey drifts of is important. Maximum storey drifts for the
structures to be constructed in our country has been restricted by Turkish
Earthquake Code (TEC) which is in force since 2007, according to the provision
of relative storey drift and A1, A2 irregularity factors. In the earthquake
code which is published as draft in 2016 and is not in force yet, it has been
planning to restrict the storey drifts for with and without gap conditions of
infill wall - frame connections. First of all, it is aimed to investigate the
limits of maximum reduced relative storey drift under specified conditions
according to TEC 2007. In this study, the maximum values of allowable reduced
storey drifts were specified separately for reinforced concrete buildings which
have 2.75m – 4.25m storey height interval, according to limitations specified
in section of TEC 2007 that is “Calculation and Limitation of Effective
Relative Storey Drifts” for each of the Structural System Behavior Factors (R).
Additionally, as an example, maximum relative story drifts have calculated
according to “A1- Torsional Irregularity” section of TEC 2007 by using the
relative storey drifts which belongs to a building from literature, and for
this building, maximum relative storey drifts has calculated according to “B2-
Interstorey Stiffness Irregularity” section of TEC 2007 for variable
interstorey heights. At the end of the study, maximum values of relative storey
drifts in the floor have revealed according to average storey drifts and storey
height ratios.

Kaynakça

  • 1. Saiidi, M., and M.A. Sozen, Simple nonlinear seismic analysis of R/C structures. Journal of Structural Engineering, 1981. 107: 937-952.
  • 2. Iwan, W.D., Drift spectrum: measure of demand for earthquake ground motions. Journal of Structural Engineering, 1997. 123: 397–404.
  • 3. Tekeli, H., A. Tüken, M. Türkmen, and A. Atımtay, Depreme Maruz Yapının Ötelenmesinin Basit Hesabı: Kapalı Çözüm. Antalya Yöresinin İnşaat Mühendisliği Sorunları Kongresi: Antalya, 2005. Vol:1, p 190-203. (in Turkish)
  • 4. Tekeli, H., F. Demir, and E. Atımtay, Çerçeveli ve Perdeli-Çerçeveli Betonarme Binaların Ötelenmesi: Analitik Çözümler, Journal of the Faculty of Engineering and Architecture of Gazi University, 2008. Vol: 23, No 1, 9-19. (in Turkish)
  • 5. Lu, Y., X. Gu, and J. Wei, Prediction of seismic drifts in multi-storey frames with a new storey capacity factor. Engineering Structures, 2009. 31;345-357.
  • 6. TEC. Deprem Bölgelerinde Yapılacak Binalar Hakkında Esaslar, The Ministry of Public Works and Settlement, 2007, Ankara. (in Turkish)
  • 7. Sindel, Z., R. Akbaş, and S.S. Tezcan, Drift control and damage in tall buildings. Engineering Structures, 1996 18: 957-966.
  • 8. TEC. Türkiye Bina ve Deprem Yönetmeliği (Draft), T.C. Disaster and Emergency Management Presidency, 2016, Ankara. (in Turkish)
Toplam 8 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Research Articles
Yazarlar

Muhammet Erdem

Murat Bikçe

Yayımlanma Tarihi 15 Aralık 2018
Gönderilme Tarihi 9 Mart 2018
Kabul Tarihi 28 Mayıs 2018
Yayımlandığı Sayı Yıl 2018 Cilt: 2 Sayı: 3

Kaynak Göster

APA Erdem, M., & Bikçe, M. (2018). Investigation on limitation of reduced relative storey drifts according to TEC 2007. International Advanced Researches and Engineering Journal, 2(3), 223-228.
AMA Erdem M, Bikçe M. Investigation on limitation of reduced relative storey drifts according to TEC 2007. Int. Adv. Res. Eng. J. Aralık 2018;2(3):223-228.
Chicago Erdem, Muhammet, ve Murat Bikçe. “Investigation on Limitation of Reduced Relative Storey Drifts According to TEC 2007”. International Advanced Researches and Engineering Journal 2, sy. 3 (Aralık 2018): 223-28.
EndNote Erdem M, Bikçe M (01 Aralık 2018) Investigation on limitation of reduced relative storey drifts according to TEC 2007. International Advanced Researches and Engineering Journal 2 3 223–228.
IEEE M. Erdem ve M. Bikçe, “Investigation on limitation of reduced relative storey drifts according to TEC 2007”, Int. Adv. Res. Eng. J., c. 2, sy. 3, ss. 223–228, 2018.
ISNAD Erdem, Muhammet - Bikçe, Murat. “Investigation on Limitation of Reduced Relative Storey Drifts According to TEC 2007”. International Advanced Researches and Engineering Journal 2/3 (Aralık 2018), 223-228.
JAMA Erdem M, Bikçe M. Investigation on limitation of reduced relative storey drifts according to TEC 2007. Int. Adv. Res. Eng. J. 2018;2:223–228.
MLA Erdem, Muhammet ve Murat Bikçe. “Investigation on Limitation of Reduced Relative Storey Drifts According to TEC 2007”. International Advanced Researches and Engineering Journal, c. 2, sy. 3, 2018, ss. 223-8.
Vancouver Erdem M, Bikçe M. Investigation on limitation of reduced relative storey drifts according to TEC 2007. Int. Adv. Res. Eng. J. 2018;2(3):223-8.



Creative Commons License

Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.