TY - JOUR T1 - Cytotoxicity Evaluation of Different Types of CAD/CAM Blocks TT - Farklı CAD/CAM Blokların Sitotoksisite Değerlendirmesi AU - Coşkun, Fikret Özgür AU - Akbaba, Giray Buğra AU - Atala, Mustafa Hayati AU - Özüdoğru, Semanur PY - 2023 DA - August DO - 10.15311/selcukdentj.1199010 JF - Selcuk Dental Journal JO - Selcuk Dent J PB - Selcuk University WT - DergiPark SN - 2148-7529 SP - 462 EP - 467 VL - 10 IS - 2 LA - en AB - Aim: The aim of this study is to determine the cytotoxic effects of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) blocks produced by different companies on human peripheral blood lymphocytes by MTT assay.Methods: Six different CAD/CAM materials were investigated: feldspar ceramic VM (Vitablocks Mark II ), resin nano-ceramic LU (Lava Ultimate), hybrid ceramic C (Cerasmart), leucite-reinforced ceramic LRF (GC LRF), zirconia-reinforced lithium silicate ceramic VS (Vita Suprinity), polymer-infiltrated ceramic-network VE (Vita Enamic). A total of 36 disc-shaped samples (Ø: 5 mm; h: 2 mm) were prepared from commercial blanks and blocks. Cell proliferation and cytotoxicity were assessed at 24h and 48h using MTT assay. The data were statistically evaluated with the Two-way ANOVA test (p < 0.05).Results: MTT viability data at 24 h showed that group VM and LU blocks were mildly cytotoxic, but there was no statistically significant difference when compared with other groups (p>0.05). It was determined that all blocks caused cell proliferation after 48 hours of exposure (p>0.05). It has been shown that all blocks whose cytotoxic effects were investigated did not cause any toxic effects (except VM and LU for 24 h) at different application times (24 h and 48 h).Conclusion: Based on the results obtained and the limitations of the current in vitro study, the tested materials were not cytotoxic. Only VM and LU caused negligible cytotoxicity at 24-hour exposure. KW - human peripheral lymphocytes KW - cytotoxicity KW - CAD/CAM blocks N2 - Amaç: Bu çalışmanın amacı, farklı firmalar tarafından üretilen Computer Aided Design (CAD) ve Computer Aided Manufacturing (CAM) bloklarının insan periferik kan lenfositleri üzerindeki sitotoksik etkilerini MTT testi ile belirlemektir.Yöntem: Altı farklı CAD/CAM materyali araştırıldı: feldspat seramik VM (Vitablocks Mark II), rezin esaslı nano-seramik LU (Lava Ultimate), hibrit seramik C (Cerasmart), lösitle güçlendirilmiş cam seramik LRF (GC LRF), zirkonya ile güçlendirilmiş lityum silikat seramik VS (Vita Suprinity), polimer infiltrasyonu ile güçlendirilmiş cam seramik VE (Vita Enamic). CAD/CAM bloklardan toplam 36 disk şeklinde numune (Ø: 5 mm; h: 2 mm) hazırlandı. Hücre proliferasyonu ve sitotoksisite, MTT testi kullanılarak 24. ve 48. saatlerde değerlendirildi. Veriler İki Yönlü ANOVA testi ile istatistiksel olarak değerlendirildi (p < 0.05).Bulgular: 24 saatteki MTT canlılık verileri, grup VM ve LU bloklarının hafif sitotoksik olduğunu gösterdi, ancak diğer gruplarla karşılaştırıldığında istatistiksel olarak anlamlı bir fark yoktu (p>0.05). Tüm blokların 48 saat sonra hücre çoğalmasına neden olduğu belirlendi (p>0.05). Sitotoksik etkileri araştırılan tüm blokların farklı uygulama sürelerinde (24 saat ve 48 saat) herhangi bir toksik etkiye (24 saat VM ve LU hariç) neden olmadığı gösterildi.Sonuç: Elde edilen sonuçlara ve mevcut in vitro çalışmanın sınırlamalarına dayanarak, test edilen materyaller sitotoksik değildi. 24 saatlik sonuçlarda VM ve LU ihmal edilebilir sitotoksisiteye neden oldu. CR - [1] Pagano S, Lombardo G, Caponi S, Costanzi E, Di Michele A, Bruscoli S, et al. Bio-mechanical characterization of a CAD/CAM PMMA resin for digital removable prostheses. Dent Mater. 2021;37(3):e118-e130. doi:10.1016/j.dental.2020.11.003 CR - [2] Ramanathan M, Panneerselvam E, Krishna Kumar Raja VB. 3D planning in mandibular fractures using CAD/CAM surgical splints - A prospective randomized controlled clinical trial. J Craniomaxillofac Surg. 2020;48(4):405-412. doi:10.1016/j.jcms.2020.02.004 CR - [3] Goujat A, Abouelleil H, Colon P, Jeannin C, Pradelle N, SeuxD, et al. Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies. J Prosthet Dent. 2019;121(4):590-597.e3. doi:10.1016/j.prosdent.2018.06.006 CR - [4] Zarone F, Russo S, Sorrentino R. From porcelain-fused-to-metal to zirconia: clinical and experimental considerations. Dent Mater. 2011;27(1):83-96. doi:10.1016/j.dental.2010.10.024 CR - [5] Guess PC, Selz CF, Steinhart YN, Stampf S, Strub JR. Prospective clinical split-mouth study of pressed and CAD/CAM all-ceramic partial-coverage restorations: 7-year results. Int J Prosthodont. 2013;26(1):21-25. doi:10.11607/ijp.3043 CR - [6] Aktas G, Yerlikaya H, Akca K. Mechanical Failure of Endocrowns Manufactured with Different Ceramic Materials: An In Vitro Biomechanical Study. J Prosthodont. 2018;27(4):340-346. doi:10.1111/jopr.12499 CR - [7] Alamoush RA, Kushnerev E, Yates JM, Satterthwaite JD, Silikas N. Response of two gingival cell lines to CAD/CAM composite blocks. Dent Mater. 2020;36(9):1214-1225. doi:10.1016/j.dental.2020.05.014 CR - [8] Atay A, Gürdal I, Bozok Çetıntas V, Üşümez A, Cal E. Effects of New Generation All-Ceramic and Provisional Materials on Fibroblast Cells. J Prosthodont. 2019;28(1):e383-e394. doi:10.1111/jopr.12915 CR - [9] Lauvahutanon S, Takahashi H, Shiozawa M, Iwasaki N, Asakawa Y, Oki M et al. Mechanical properties of composite resin blocks for CAD/CAM. Dent Mater J. 2014;33(5):705-710. doi:10.4012/dmj.2014-208 CR - [10] Sieper K, Wille S, Kern M. Fracture strength of lithium disilicate crowns compared to polymer-infiltrated ceramic-network and zirconia reinforced lithium silicate crowns. J Mech Behav Biomed Mater. 2017;74:342-348. doi:10.1016/j.jmbbm.2017.06.025 CR - [11] Silva LHD, Lima E, Miranda RBP, Favero SS, Lohbauer U, Cesar PF. Dental ceramics: a review of new materials and processing methods. Braz Oral Res. 2017;31(suppl 1):e58. Published 2017 Aug 28. doi:10.1590/1807-3107BOR-2017.vol31.0058 CR - [12] Elsaka SE, Elnaghy AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater. 2016;32(7):908-914. doi:10.1016/j.dental.2016.03.013 CR - [13] Awada A, Nathanson D. Mechanical properties of resin-ceramic CAD/CAM restorative materials. J Prosthet Dent. 2015;114(4):587-593. doi:10.1016/j.prosdent.2015.04.016 CR - [14] Jakovac M, Zivko-Babic J, Curkovic L, Aurer A. Measurement of ion elution from dental ceramics. J Eur Ceram Soc.2006;26(9):1695-1700. doi:10.1016/j.jeurceramsoc.2005.03.242. CR - [15] Lygre H. Prosthodontic biomaterials and adverse reactions: a critical review of the clinical and research literature. Acta Odontol Scand. 2002;60(1):1-9. doi:10.1080/000163502753471925 CR - [16] Elshahawy WM, Watanabe I, Kramer P. In vitro cytotoxicity evaluation of elemental ions released from different prosthodontic materials. Dent Mater. 2009;25(12):1551-1555. doi:10.1016/j.dental.2009.07.008 CR - [17] Shim JS, Kim HC, Park SI, Yun HJ, Ryu JJ. Comparison of Various Implant Provisional Resin Materials for Cytotoxicity and Attachment to Human Gingival Fibroblasts. Int J Oral Maxillofac Implants. 2019;34(2):390-396. doi:10.11607/jomi.6707 CR - [18] Elshahawy W, Shohieb F, Yehia H, Etman W, Watanabe I, Kramer P. Cytotoxic effect of elements released clinically from gold and CAD-CAM fabricated ceramic crowns. Tanta Dent. J. 2014;11, 189–193. CR - [19] Gupta SK, Saxena P, Pant VA, Pant AB. Release and toxicity of dental resin composite. Toxicol Int. 2012;19(3):225-234. doi:10.4103/0971-6580.103652 CR - [20] Williams DF. On the mechanisms of biocompatibility. Biomaterials. 2008;29(20):2941-2953. doi:10.1016/j.biomaterials.2008.04.023 CR - [21] Mosmann T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods. 1983;65(1-2):55-63. doi:10.1016/0022-1759(83)90303-4 CR - [22] Alcaide M, Portolés P, López-Noriega A, Arcos D, Vallet-Regí M, Portolés MT. Interaction of an ordered mesoporous bioactive glass with osteoblasts, fibroblasts and lymphocytes, demonstrating its biocompatibility as a potential bone graft material. Acta Biomater. 2010;6(3):892-899. doi:10.1016/j.actbio.2009.09.008 CR - [23] Ojeda G, Ronda M, Ballester S, Díez-Orejas R, Feito MJ, García-Albert L, et al. A hyperreactive variant of a CD4+ T cell line is activated by syngeneic antigen presenting cells in the absence of antigen. Cell Immunol. 1995;164(2):265-278. doi:10.1006/cimm.1995.1170 CR - [24] Rizo-Gorrita M, Herráez-Galindo C, Torres-Lagares D, Serrera-Figallo MÁ, Gutiérre-Pérez JL. Biocompatibility of Polymer and Ceramic CAD/CAM Materials with Human Gingival Fibroblasts (HGFs). Polymers (Basel). 2019;11(9):1446. Published 2019 Sep 3. doi:10.3390/polym11091446 CR - [25] Grenade C, De Pauw-Gillet MC, Gailly P, Vanheusden A, Mainjot A. Biocompatibility of polymer-infiltrated-ceramic-network (PICN) materials with Human Gingival Fibroblasts (HGFs). Dent Mater. 2016;32(9):1152-1164. doi:10.1016/j.dental.2016.06.020 CR - [26] Pae A, Lee H, Kim HS, Kwon YD, Woo YH. Attachment and growth behaviour of human gingival fibroblasts on titanium and zirconia ceramic surfaces. Biomed Mater. 2009;4(2):025005. doi:10.1088/1748-6041/4/2/025005 CR - [27] Tetè S, Zizzari VL, Borelli B, De Colli M, Zara S, Sorrentino R, et al. Proliferation and adhesion capability of human gingival fibroblasts onto zirconia, lithium disilicate and feldspathic veneering ceramic in vitro. Dent Mater J. 2014;33(1):7-15. doi:10.4012/dmj.2013-185 CR - [28] Goetze E, Moergel M, Gielisch M, Kämmerer PW. Safety of resection margins in CAD/CAM-guided primarily reconstructed oral squamous cell carcinoma-a retrospective case series. Oral Maxillofac Surg. 2019;23(4):459-464. doi:10.1007/s10006-019-00797-8 CR - [29] Sabaliauskas V, Juciute R, Bukelskiene V, Rutkunas V, Trumpaite-Vanagiene R, Puriene A. In vitro evaluation of cytotoxicity of permanent prosthetic materials. Stomatologija. 2011;13(3):75-80. CR - [30] Pera P, Conserva E, Pin D, Acquaviva A, Riboldi A, Mariottini GL, et al. Cytotoxicity in vitro analysis of ceramic materials for ''metal free'' prosthetic substructures. Minerva Stomatol. 2005;54(6):363-371. CR - [31] Sjögren G, Sletten G, Dahl JE. Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests. J Prosthet Dent. 2000;84(2):229-236. doi:10.1067/mpr.2000.107227 CR - [32] Messer RL, Lockwood PE, Wataha JC, Lewis JB, Norris S, Bouillaguet S. In vitro cytotoxicity of traditional versus contemporary dental ceramics. J Prosthet Dent. 2003;90(5):452-458. doi:10.1016/s0022-3913(03)00533-x CR - [33] Raffaelli L, Rossi Iommetti P, Piccioni E, Toesca A, Serini S, Resci F, et al. Growth, viability, adhesion potential, and fibronectin expression in fibroblasts cultured on zirconia or feldspatic ceramics in vitro. J Biomed Mater Res A. 2008;86(4):959-968. doi:10.1002/jbm.a.31693 CR - [34] Brackett MG, Lockwood PE, Messer RL, Lewis JB, Bouillaguet S, Wataha JC. In vitro cytotoxic response to lithium disilicate dental ceramics. Dent Mater. 2008;24(4):450-456. doi:10.1016/j.dental.2007.06.013 CR - [35] Campaner M, Takamiya AS, Bitencourt SB, Mazza LC, de Oliveira SHP, Shibayama R, et al. Cytotoxicity and inflammatory response of different types of provisional restorative materials. Arch Oral Biol. 2020;111:104643. doi:10.1016/j.archoralbio.2019.104643 CR - [36] Tassin M, Bonte E, Loison-Robert LS, Nassif A, Berbar T, LeGoff S, et al. Effects of High-Temperature-Pressure Polymerized Resin-Infiltrated Ceramic Networks on Oral Stem Cells. PLoS One. 2016;11(5):e0155450. Published 2016 May 19. doi:10.1371/journal.pone.0155450 CR - [37] Hussain B, Thieu MKL, Johnsen GF, Reseland JE, Haugen HJ. Can CAD/CAM resin blocks be considered as substitute for conventional resins?. Dent Mater. 2017;33(12):1362-1370. doi:10.1016/j.dental.2017.09.003 CR - [38] Krifka S, Spagnuolo G, Schmalz G, Schweikl H. A review of adaptive mechanisms in cell responses towards oxidative stress caused by dental resin monomers. Biomaterials. 2013;34(19):4555-4563. doi:10.1016/j.biomaterials.2013.03.019 CR - [39] Schweikl H, Spagnuolo G, Schmalz G. Genetic and cellular toxicology of dental resin monomers. J Dent Res. 2006;85(10):870-877. doi:10.1177/154405910608501001 CR - [40] International Standards Organization (ISO) 10993–5:1992. Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity. International Standards Organization, Geneva; Switzerland, 1992. UR - https://doi.org/10.15311/selcukdentj.1199010 L1 - https://dergipark.org.tr/en/download/article-file/2749464 ER -