TY - JOUR T1 - Post-Loading Radiographic Texture Changes After Lateral Sinus Floor Elevation: A Compartment-Based Fractal Dimension Analysis TT - Lateral Sinüs Tabanı Yükseltmesi Sonrası Yükleme Dönemindeki Radyografik Doku Değişiklikleri: Bölge Temelli Bir Fraktal Boyut Analizi AU - Yapişoğlu, Tuğçe AU - Karataş, Özkan AU - Taşkan, Mehmet Murat PY - 2026 DA - September Y2 - 2026 DO - 10.7126/cumudj.1996948 JF - Cumhuriyet Dental Journal JO - Cumhuriyet Dent J PB - Sivas Cumhuriyet University WT - DergiPark SN - 1302-5805 SP - 544 EP - 551 VL - 29 IS - 3 LA - en AB - Objectives: This retrospective radiographic study aimed to compare post-loading fractal dimension (FD) changes in loaded residual bone and grafted sinus areas with those in corresponding non-loaded areas after lateral sinus floor elevation with simultaneous implant placement.Materials and Methods: Thirty-five patients treated in the posterior maxilla were included. Panoramic radiographs obtained on the day of surgery (T0) and 18–24 months after functional loading (T1) were analyzed. FD analysis was performed using ImageJ according to the box-counting method. Loaded residual bone and loaded grafted area values were calculated as the mean of mesial and distal implant-adjacent regions, while non-loaded residual bone and grafted areas were evaluated separately. Longitudinal changes were calculated as ΔFD = T1 − T0. Within-region changes and paired comparisons between loaded and corresponding non-loaded areas were analyzed using paired-samples t-tests.Results: FD increased significantly in loaded residual bone from 0.719 ± 0.114 to 0.849 ± 0.059 (p < 0.001), whereas the non-loaded residual bone area remained stable (0.955 ± 0.105 to 0.974 ± 0.129; p = 0.220). FD remained unchanged in the loaded grafted area (0.811 ± 0.117 to 0.806 ± 0.096; p = 0.783), but decreased significantly in the non-loaded grafted area (0.962 ± 0.119 to 0.798 ± 0.055; p < 0.001). ΔFD differed significantly between loaded and non-loaded residual bone (+0.129 ± 0.096 vs. +0.019 ± 0.089; p < 0.001) and between loaded and non-loaded grafted areas (−0.005 ± 0.107 vs. −0.164 ± 0.126; p < 0.001).Conclusions: Compartment-based FD analysis revealed distinct post-loading radiographic texture patterns in residual bone and grafted sinus areas. Native residual bone and grafted compartments may exhibit different trabecular responses under the post-loading peri-implant environment. FD analysis may help monitor longitudinal radiographic pattern changes, but should not be interpreted as direct evidence of histological maturation or implant stability. KW - Dental implant KW - Fractal dimension KW - Maxillary sinus KW - Panoramic radiography KW - Sinus floor elevation N2 - Amaç: Bu retrospektif radyografik çalışmada, lateral sinüs tabanı yükseltmesi ve eş zamanlı implant yerleştirilmesi sonrasında yükleme döneminde ortaya çıkan fraktal boyut (FB) değişimlerinin, rezidüel kemik ve greftlenmiş sinüs alanlarında bölge temelli olarak değerlendirilmesi amaçlanmıştır. Bu kapsamda, implanta komşu yük alan bölgeler ile karşılık gelen yük almayan bölgeler karşılaştırılmıştır.Gereç ve Yöntemler: Çalışmaya lateral sinüs tabanı yükseltmesi ile eş zamanlı implant yerleştirilen 35 hasta dahil edilmiştir. Cerrahi günü elde edilen panoramik radyografiler T0, fonksiyonel yüklemeden 18–24 ay sonra elde edilen takip radyografileri ise T1 olarak tanımlanmıştır. Yük alan rezidüel kemik ve yük alan greftlenmiş alan değerleri, implanta komşu mezial ve distal bölgelerden elde edilen FB değerlerinin ortalaması alınarak hesaplanmıştır. Yük almayan rezidüel kemik ve yük almayan greftlenmiş alanlar ise ayrı olarak değerlendirilmiştir. Longitudinal değişim ΔFB = T1 − T0 şeklinde hesaplanmıştır. Bölge içi T0–T1 değişimleri ile yük alan ve karşılık gelen yük almayan bölgeler arasındaki ΔFB farkları eşleştirilmiş örneklem t testi ile analiz edilmiştir.Bulgular: Yük alan rezidüel kemikte FB değeri T0’dan T1’e anlamlı olarak artmıştır (0.719 ± 0.114-0.849 ± 0.059; p < 0.001). Buna karşılık, yük almayan rezidüel kemik alanında anlamlı bir değişim izlenmemiştir (0.955 ± 0.105-0.974 ± 0.129; p = 0.220). Yük alan greftlenmiş alanda FB değeri stabil kalmıştır (0.811 ± 0.117-0.806 ± 0.096; p = 0.783). Ancak yük almayan greftlenmiş alanda anlamlı FB azalması saptanmıştır (0.962 ± 0.119-0.798 ± 0.055; p < 0.001). ΔFB değerleri, yük alan ve yük almayan rezidüel kemik bölgeleri arasında (+0.129 ± 0.096 ve +0.019 ± 0.089; p < 0.001) ve yük alan ve yük almayan greftlenmiş alanlar arasında (−0.005 ± 0.107 ve −0.164 ± 0.126; p < 0.001) anlamlı farklılık göstermiştir.Sonuçlar: Bölge temelli FB analizi, lateral sinüs tabanı yükseltmesi ve eş zamanlı implant yerleştirilmesi sonrasında rezidüel kemik ve greftlenmiş sinüs alanlarının yükleme sonrası farklı radyografik doku paternleri sergileyebileceğini göstermiştir. Bulgular, doğal rezidüel kemik ile greftlenmiş alanların yükleme sonrası peri-implant çevrede farklı trabeküler yanıtlar gösterebileceğine işaret etmektedir. FB analizi, sinüs augmentasyonu ve implant yüklemesi sonrasında longitudinal radyografik patern değişimlerinin izlenmesinde yardımcı bir yöntem olarak değerlendirilebilir. Ancak bu bulgular histolojik maturasyonun, greft kalitesinin veya implant stabilitesinin doğrudan kanıtı olarak yorumlanmamalıdır. CR - 1. Sailer I, Karasan D, Todorovic A, Ligoutsikou M, Pjetursson B E. Prosthetic failures in dental implant therapy. Periodontol 2000 2022;88(1):130-144. CR - 2. Bosshardt D D, Chappuis V, Buser D. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontol 2000 2017;73(1):22-40. CR - 3. Manzano G, Montero J, Martín-Vallejo J, Del Fabbro M, Bravo M, Testori T. Risk factors in early implant failure: a meta-analysis. Implant Dent 2016;25(2):272-280. CR - 4. Soler-Alcaraz S, Guerrero-Sánchez Y, Del Águila O G, Bernabeu-Mira J C, Camacho-Alonso F. Analysis of bone quality formation in sinus lifts with immediate implants. BMC Oral Health 2024;24(1):1214. CR - 5. Akpınar H, Ozbey F, Yıldırım B. Comparison of trabecular bone structure using fractal dimension analysis in patients undergoing lateral window and transcrestal sinus lift procedures: a retrospective cohort study. BMC Med Imaging 2025;25(1):430. CR - 6. Raghoebar GM, Onclin P, Boven GC, Vissink A, Meijer HJ. Long‐term effectiveness of maxillary sinus floor augmentation: a systematic review and meta‐analysis. J Clin Periodontol 2019;46:307-318. CR - 7. Scaini R, Saleh M H, Lai H C, Sangiorgi M, Zucchelli G, Testori T. Indications and Regenerative techniques for lateral window sinus floor elevation with ridge augmentation. Clin Implant Dent Relat Res 2025;27(3):e70007. CR - 8. Yuksel IB, Altiparmak F, Gurses G, Akti A, Alic M, Tuna S. Radiographic evidence of immature bone architecture after sinus grafting: a multidimensional image analysis approach. Diagnostics 2025;15(14):1742. CR - 9. Wen C, Zhang Q. Pilot study of fractal dimension analysis of osteogenesis for bone substitute materials of Bio-Oss in lateral sinus augmentation. Plos one 2023;18(12):e0296248. CR - 10. Duyck J, Vandamme K. The effect of loading on peri-implant bone: a critical review of the literature. Bone Response to Dental Implant Materials. In: Adriano P (eds.) Woodhead Publishing 2017:139-161. CR - 11. Li Z, Müller R, Ruffoni D. Bone remodeling and mechanobiology around implants: insights from small animal imaging. J Orthop Res 2018;36(2):584-593. CR - 12. Handschel J, Simonowska M, Naujoks C, Depprich R A, Ommerborn M A, Meyer U, et al. A histomorphometric meta-analysis of sinus elevation with various grafting materials. Head Face Med 2009;5(1):12. CR - 13. Torul D, Yilmaz MF, Erzurumlu ZU, Omezli MM. Evaluation of changes in peri-implant bone architecture at different stages of implant treatment with fractal analysis. J Stomatol Oral Maxillofac Surg 2025;126(6S):102508. CR - 14. Dundar N, Aslan E, Mutlu O. Fractal dimension, lacunarity, and bone area fraction analysis of peri-implant trabecular bone after prosthodontic loading. Oral Radiol 2025;41(1):120-130. CR - 15. Sahrmann P, Kühl S, Dagassan‐Berndt D, Bornstein MM, Zitzmann NU. Radiographic assessment of the peri‐implant site. Periodontol 2000 2024;95(1):70-86. CR - 16. Schmidt JC, Gutekunst C-J, Dagassan-Berndt D, Schmidlin P R, Walter C. Comparison of two-dimensional and three-dimensional radiographs using clinically relevant parameters. Dent J 2019;7(2):50. CR - 17. Oliveira ML. Digital Dental Radiology and Diagnostics—From 2D to 3D. Aust Dent J 2025;70:S50-S66. CR - 18. Kato CN, Barra SG, Tavares NP, Amaral TM, Brasileiro CB, Mesquita RA, et al. Use of fractal analysis in dental images: a systematic review. Dentomaxillofac Radiol 2020;49(2):20180457. CR - 19. Magat G, Oncu E, Ozcan S, Orhan K. Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis. J Korean Assoc Oral Maxillofac Surg 2022;48(1):41-49. CR - 20. Sancar B, Dedeoğlu N, Çetiner Y, Aral C A, Altun O. Using the fractal dimension method to assess ossification after open sinus lift surgery. J Health Sci Med 2022;5(1):326-330. CR - 21. Sozen E, Aytugar E, Ertas E T, Cene E, Kara M I. Evaluation of graft osteogenesis using fractal dimension analysis on cone-beam computed tomography images following maxillary sinus lift surgery. BMC Oral Health 2025;25(1):1346. CR - 22. Faul F, Erdfelder E, Buchner A, Lang A-G. Statistical power analyses using G* Power 3.1: Tests for correlation and regression analyses. Behav Res Methods 2009;41(4):1149-1160. CR - 23. White S C, Rudolph D J. Alterations of the trabecular pattern of the jaws in patients with osteoporosis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999;88(5):628-635. CR - 24. Iványi D, Kivovics M, Balázs R, Németh O. Fractal analysis as a predictor of early implant loss: a retrospective study. Int Dent J 2025;75(6):103880. CR - 25. Vadiati Saberi B, Khosravifard N, Nooshmand K, Dalili Kajan Z, Ghaffari ME. Fractal analysis of the trabecular bone pattern in the presence/absence of metal artifact–producing objects: comparison of cone-beam computed tomography with panoramic and periapical radiography. Dentomaxillofac Radiol 2021;50(6):20200559. CR - 26. Oliveira-Santos N, Silva A G, Gaêta-Araujo H, Groppo F C. Influence of binarization methods on the fractal dimension of alveolar bone using digital radiographs. Oral Surg Oral Med Oral Pathol Oral Radiol 2023;136(5):649-655. CR - 27. Kuzu TE, Akkoca F, Gurgan C. Evaluation of early changes in periimplantal alveolar bone micromarchitecture during immediate implantation using fractal analysis: a retrospective study. Cumhuriyet Dent J 2025;28(1):29–35. UR - https://doi.org/10.7126/cumudj.1996948 L1 - https://dergipark.org.tr/en/download/article-file/6233477 ER -