@article{article_341826, title={A novel volumetric analysis using cad/cam scanners in gingival recession treatment}, journal={Medical Science and Discovery}, volume={4}, pages={72–79}, year={2017}, DOI={10.17546/msd.341826}, author={Sahin Aydinyurt, Hacer and Ertugrul, Abdullah Seckin}, keywords={Subepitelial connective tissue grafts,Enamel matrix derivatives,Gingival recession,CAD/CAM,Dentistry,Periodontics}, abstract={<div> <table align="left" cellspacing="0" cellpadding="0"> <tbody> <tr> <td align="left" valign="top" style="margin:0px;padding:0cm 7.05pt;border:0px rgb(0,0,0);background-color:transparent;"> <p style="margin:0px 0px 8px;text-align:justify;"> <font size="2"> <font face="Times New Roman"> <b> <span lang="en-gb" style="margin:0px;color:rgb(0,112,192);" xml:lang="en-gb">Objective: </span> </b> <span lang="en-gb" style="margin:0px;" xml:lang="en-gb">In this study, randomized clinical trial (RCT), the aim was to compare clinical periodontal data of subepithelial connective tissue graft (SCTG) group and SCGT+enamel matrix derivatives (EMD) group in terms of gained gingiva volume (GGV) and gained gingiva surface area (GGSA) by scanners of computer-aided design/computer-aided manufacturing (CAD/CAM) devices. </span> </font> </font> </p> <p style="margin:0px 0px 8px;text-align:justify;"> <font size="2"> <font face="Times New Roman"> <b> <span lang="en-gb" style="margin:0px;color:rgb(0,112,192);" xml:lang="en-gb">Material and Methods: </span> </b> <span lang="en-gb" style="margin:0px;" xml:lang="en-gb">In this study, a total of 35 Miller class I-II gingival recession defects were involved (n=17 in SCTG group, n=18 in SCTG+EMD group). In addition to, periodontal clinical parameters, and <span style="margin:0px;">  </span>three dimensional (3D) images were recorded by using CAD/CAM system before the treatment, at the 1 <sup>st </sup> <span style="margin:0px;">  </span>month and the 6 <sup>th </sup> months after the treatment. The images were superimposed by using softwares and GGV, and GGSA were calculated. </span> </font> </font> </p> <p style="margin:0px 0px 8px;text-align:justify;"> <font size="2"> <font face="Times New Roman"> <b> <span lang="en-gb" style="margin:0px;color:rgb(0,112,192);" xml:lang="en-gb">Results: </span> </b> <span lang="en-gb" style="margin:0px;" xml:lang="en-gb">There was no significant difference in terms of GGV and GGSA values at the 1 <sup>st </sup> month and 6 <sup>th </sup> months between SCTG+EMD and SCTG groups. Similarly, there was no <span style="margin:0px;">  </span>significant difference in periodontal clinical parameters between groups. </span> </font> </font> </p> <p style="margin:0px 0px 8px;text-align:justify;"> <font size="2"> <font face="Times New Roman"> <b> <span lang="en-gb" style="margin:0px;color:rgb(0,112,192);" xml:lang="en-gb">Conclusion: </span> </b> <span lang="en-gb" style="margin:0px;" xml:lang="en-gb">Images obtained from CAD/CAM system can be easily used in calculating GGV and GGSA data after the gingival recession treatment and in determining of the success of administered treatment. It is expected that the evaluation of the success of many therapeutic approaches for periodontal treatment will be carried out by using CAD/CAM system in the future. </span> </font> </font> </p> </td> </tr> </tbody> </table> </div>}, number={10}, publisher={Zafer AKAN}