@article{article_382561, title={Effect of the Radon Background Fluctuation on the Low Activity Measurement of the <sup>214</sup>Pb, <sup>214</sup>Bi and <sup>226</sup>Ra}, journal={Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi}, volume={21}, pages={345–349}, year={2017}, DOI={10.19113/sdufbed.12103}, author={Ağuş, Yusuf}, keywords={Radon background fluctuation,Low activity; 214Pb; 214Bi; 226Ra}, abstract={&lt;p&gt; &lt;span lang="en-us" xml:lang="en-us"&gt; &lt;strong&gt; &lt;/strong&gt;In this study, radon background fluctuation effect on the measurement of &lt;sup&gt;214 &lt;/sup&gt;Pb, &lt;sup&gt;214 &lt;/sup&gt;Bi and &lt;sup&gt;226 &lt;/sup&gt;Ra low level activity concentrations were investigated in ventilated laboratory. For this purpose, detectors which had 150% and 20% efficiencies were used. In spite of the air ventilation, radon background fluctuation &lt;strong&gt; &lt;/strong&gt;effect on the low level activity measurement was observed. 20% efficiency detector measured activity discrepancies were 5.7% for &lt;sup&gt;214 &lt;/sup&gt;Pb, 8.7% for &lt;sup&gt;214 &lt;/sup&gt;Bi and 5.8% for &lt;sup&gt;226 &lt;/sup&gt;Ra. 150% efficiency detector measured activity discrepancies were 13.8% for &lt;sup&gt;214 &lt;/sup&gt;Pb, 11.5% for &lt;sup&gt;214 &lt;/sup&gt;Bi and 12.7% for &lt;sup&gt;226 &lt;/sup&gt;Ra. &lt;/span&gt; &lt;/p&gt;}, number={2}, publisher={Süleyman Demirel University}