TY - JOUR T1 - ERZİNCAN KENTİ ATIKSULARININ KARAKTERİZASYONU ve GPS-X BİLGİSAYAR PROGRAMI KULLANILARAK MODELLENMESİ TT - CHARACTERIZATION of ERZİNCAN CITY WASTEWATER TREATMENT PLANT and MODELLED by USING GPS-X COMPUTER PROGRAM AU - Turan, Tuba AU - Nuhoğlu, Alper PY - 2011 DA - August JF - Journal of Science and Technology of Dumlupınar University JO - DPÜFBED PB - Kütahya Dumlupinar University WT - DergiPark SN - 2651-2769 SP - 41 EP - 48 IS - 025 LA - tr AB - ErzincanKenti Atıksu Arıtma Tesisi’nde yürütülen bu çalışma üç ana kademedegerçekleştirilmiştir.İlk olarak tesisin mevcut işletme stratejisi ve arıtma performansıdeğerlendirilmiş ve iyi işletilmediği sonucuna varılmıştır.İkinci kademedeErzincan kenti evsel atıksuları karbonlu ve azotlu maddelere göre karakterizeedilmiş ve giriş suyunda ölçülen parametrelerin ortalama değerleri şu şekildebulunmuştur; TKOI: 430mg/ L, ÇKOI: 233 mg/L, NO3-N: 0.36 mg/L, NH4-N: 32 mg/L,çözünmüş organik N: 11 mg/ L, toplam N: 43 mg/L ve AKM: 199 mg/L. İncelenenperiyotta çeşitli parametrelere göre tesisin arıtım performansı şu şekildedir;TKOI giderme verimi %80-87, ÇKOI giderme oranı %73-89 ,TN giderim oranının%6,6-36,8 ve NH4-N giderme veriminin %87,3-95,4 arasında olduğubelirlenmiştir.Çalışmanın üçüncü kısmında GPS-X bilgisayar programıkullanılarak mevcut tesis matematiksel olarak modellenmiş ve ölçülen değerlerlemodelin hesapladığı değerler arasında iyi bir uyum olduğu tespit edilmiştir.Modelde biyokinetik reaksiyonlar için IAWQ Çalışma Grubu 1No’lu modeli,çöktürme havuzu için katmanlı çöktürücü modeli kullanılmıştır. KW - atıksu arıtımı KW - nitrifikasyon KW - denitrifikasyon KW - GPS-X bilgisayar programı N2 - There arethree major steps in this study in which it was performed at the Erzurum CityWastewater Treatment Plant. Firstly, current operational strategies andtreatment performance were evaluated fort he plant and it was concluded thatthe plant was poorly operated. At the second stage, domestic wastewater ofErzincan City were characterized for carbonaceous and nitrogenous substances,and average values of parameters measured in influent were found as follows;TCOD:430 mg/L, SCOD:233 mg/L, NO3-N: 0,36 mg/L, NH4-N: 32mg/L, dissolved organic N: 11 mg/ L,Total N:  43 mg/L and SS:199 mg/L. During the fieldstudy period, removal rates for TCOD was varied between 80-87 %, SCOD remowalrates varied between 73-89%, TN removal rates varied between 6,6-36,8% and NH4-Nremoval rates varied between 87,3-95,4%. As a third stage of the study,treatment plant was modelled mathematically by using GPS-X computer software andfor various parameters it was observed that there was a good  agrement between measured and computedvalues. In mathematical modelling, IAWQ Task Group Model No 1 was used forbiochemical reactions and layered setler model was chosen for final settling tank. CR - [1] U. Jeppson., 1996.,Modelling Aspects of Wastewater Treatment Processes., Phd Thesis., Department of Industrial Electrical Engineering and Automation, Lund Institude of Technology, Swedwn, p 12-85 CR - [2] M. Henze., C.P.L. Grady., W.Gujer., G.V.R. Marais.,T. Matsuo., 1987., Activated Sludge No.1-IAWPRC Scientific and Technical Report No.1, London, UK, p 1-35 CR - [3] M. Puteh., K. Minekawa., N. Hashimoto., 1999., Modelling of Activated Sludge Wastewater Treatment Processes., Bioprocesses Eng.,21,(2) 249. CR - [4]G. Tchobanoglous and F.L., Burton, “Wastewater Engineering Treatment Disposal and Reuse.,McGraw-Hill International Editions, p 529-603 CR - [5] M. Henze., 1992., Characterization of Wastewater for Modelling of Activated Sludge Processes., Wat.Sci.Tech., 25, [6] B.B. Baykal and D. Büktel., 1992., Canlılığın Dahil Edildiği Modellerle Aktif Çamur Sistem Simülasyonları., SKKD., 2, (1), 29. CR - [6] B.B. Baykal and D. Büktel., 1992., Canlılığın Dahil Edildiği Modellerle Aktif Çamur Sistem Simülasyonları., SKKD., 2, (1), 29. UR - https://dergipark.org.tr/en/pub/dpufbed/issue//404569 L1 - https://dergipark.org.tr/en/download/article-file/439354 ER -