TY - JOUR T1 - Impact of contact lens wear on ocular surface and Meibomian glands TT - Kontakt lens kullanımının oküler yüzey ve Meibomian bezleri üzerine etkileri AU - Palamar, Melis AU - Barut Selver, Özlem AU - Menteş, Jale AU - Yağcı, Ayşe PY - 2018 DA - December DO - 10.19161/etd.416656 JF - Ege Tıp Dergisi JO - EJM PB - Ege University WT - DergiPark SN - 1016-9113 SP - 191 EP - 194 VL - 57 IS - 4 LA - en AB - Aim:To determine the impact of contact lens (CL) wear on the ocular surface andMeibomian glands (MG).Materialsand Methods: 24 silicone hydrogel CL wearers for a minimumof 5 years (Group 1) and 26 healthy volunteers (Group 2) were included in thisretrospective study. Best corrected visual acuity, Oxford scoring, tear filmbreak-up time (T-BUT), Schirmer 1 test, Ocular Surface Disease Index (OSDI)scoring and MG evaluation by infrared captures of optic coherence tomography(OCT) were performed. Loss of the MG was scored blindly by a single researcher.Results:The mean age was 30.00±6.22 in Group 1 and 28.70±4.95 in Group 2 (p=0.300).Male/female ratio was 4/20 in Group 1 and 9/17 in Group 2. The average durationof CL wear was 10.70±2.70 years. The mean T-BUT in Group 1 and 2 were17.70±76.74 and 24.76±8.06 sec, respectively (p=0.002). The mean Schirmer 1test in Group 1 and 2 were 29.04±7.67 and 25.50±8.48 mm, respectively(p=0.129). The mean Oxford scale staining in Group 1 and 2 were 0.58±0.94 and0.15±0.41, respectively (p=0.040). The mean OSDI scores in Group 1 and 2 were29.36±19.25 and 23.63±21.99, respectively (p=0.334). The average upper, lowereyelid, and total meiboscores in Group 1 and 2 were 0.95±0.87, 0.66±0.73,1.60±1.40 and 0.67±0.59, 0.67±0.70 and 1.34±1.17, respectively. No statisticalsignificance was detected in any of these scores.Conclusion:CL wear has a variety of effects on ocular surface. MG has a significantinfluence on ocular surface. Meiboscoring is an effective and practical way forevaluation of the MG. KW - Contact lens wear KW - infrared imaging KW - Meibomian gland KW - meibography KW - optic coherence tomography N2 - Amaç: Yumuşak kontakt lens (KL)kullanımının oküler yüzey ve Meibomian bezleri üzerine etkisini araştırmak Gereçve Yöntem: Beş yılıaşkın süredir silikon hidrojel KL kullanım öyküsü bulunan 24 olgu (Grup 1) ve26 sağlıklı gönüllünün (Grup 2) en iyi düzeltilmiş görme keskinlikleri,Schirmer 1 testi, gözyaşı kırılma zamanı, oküler yüzey boyanması (Oxfordskalası), OSDI skoru ve meibomian bez özelliklerini içeren kayıtlarıretrospektif olarak değerlendirildi. Üst ve alt kapakların OCT meibografileri(Spectralis HRA+OCT; Heidelberg Engineering, Heidelberg, Germany) çekilerek bezkaybı açısından tek bir araştırmacı tarafından kör olarak değerlendirildi.Bulgular: Ortalama yaş Grup 1’de30.00±6.22, Grup 2’de ise 28.70±4.95 idi (p=0.300). Erkek/kadın oranı Grup 1’de4/20, Grup 2’de 9/17 idi. KL kullanım süresi 10.70±2.70 yıldı. Ortalama gözyaşıkırılma zamanı Grup 1’de 17.70±76.74, Grup 2’de 24.76±8.06 saniyeydi (p=0.002).Ortalama Schirmer 1 değeri Grup 1’de 29.04±7.67, Grup 2’de 25.50±8.48 mm idi(p=0.129). Oxford skalası puanı Grup 1’de 0.58±0.94, Grup 2’de 0.15±0.41 olupfark istatistiksel olarak anlamlıydı (p=0.040). OSDI skoru açısından gruplararası istatistiksel anlamlı fark bulunmamaktaydı (Grup 1: 29.36±19.25, Grup 2:23.63±21.99, p=0.334). Üst, alt kapak ve toplam meibomian bez skoru ortalamasıGrup 1’de sırasıyla 0.95 ±0.87, 0.66±0.73 ve 1.60±1.40, Grup 2’de sırasıyla0.67 ± 0.59, 0.67 ±0.70 ve 1.34±1.17 idi ve aralarındaki fark istatistikselolarak anlamlı değildi.Sonuç: Uzun süreli KL kullanımının,oküler yüzeye birçok farklı etkisi mevcuttur. Meibomian bezler, oküler yüzeyeönemli etkileri bulunan yapıladır. Meibobian bez skorlaması, Meibomian bezdeğerlendirmesi için etkili ve pratik bir yöntemdir. CR - Knop N, Knop E. Meibomian glands. Part I. Anatomy, embryology and histology of the Meibomian glands. Ophthalmologe 2009;106(10):872-83. CR - Nagyova B, Tiffany JM. Components responsible for the surface tension of human tears. Curr Eye Res 1999;19(1):4-11. CR - Craig JP, Tomlinson A. Importance of the lipid layer in human tear film stability and evaporation. Optom Vis Sci 1997;74(1):8-13. CR - Nelson JD, Shimazaki J, Benitez-del-Castillo JM, et al. The international workshop on meibomian gland dysfunction: Report of the definition and classification subcommittee. Invest Ophthalmol Vis Sci 2011;52(4):1930-7. CR - Arita R, Itoh K, Inoue K, Amano S. Noncontact infrared meibography to document age-related changes of the meibomian glands in a normal population. Ophthalmology 2008;115(5):911-5. CR - Pult H, Riede-Pult BH. Non-contact meibography: Keep it simple but effective. Cont Lens Anterior Eye 2012;35(2):77-80. CR - Srinivasan S, Sorbara L, Jones L, Sickenberger W. Imaging the structure of the meibomian glands. Contact Lens Spectrum 2011;7(1):52-3 CR - Nichols JJ, Sinnott LT. Tear film, contact lens, and patient- related factors associated with contact lens-related dry eye. Invest Ophthalmol Vis Sci 2006;47(4):1319-28. CR - Pisella PJ, Malet F, Lejeune S, et al. Ocular surface changes induced by contact lens wear. Cornea 2001;20(8):820-5. CR - Hatfield RO, Jordan DR, Bennett ES, Henry VA, Marohn JW, Morgan BW. Initial comfort and surface wettability: A comparison between different contact lens materials. J Am Optom Assoc 1993;64(4):271-3. CR - Nichols JJ, Mitchell GL, Nichols KK, Chalmers R, Begley C. The performance of the contact lens dry eye questionnaire as a screening survey for contact lens-related dry eye. Cornea 2002;21(5):469-75. CR - Begley CG, Caffery B, Nichols KK, Chalmers R. Responses of contact lens wearers to a dry eye survey. Optom Vis Sci 2000;77(1):40-6. CR - Arita R, Itoh K, Inoue K, Kuchiba A, Yamaguchi T, Amano S. Contact lens wear is associated with decrease of meibomian glands. Ophthalmology 2009;116(3):379-84. CR - Ngo W, Srinivasan S, Jones L. Historical overview of imaging the meibomian glands. Journal of Optometry 2013;6(1):1-8. CR - Nichols JJ, Berntsen DA, Mitchell GL, Nichols KK. An assessment of grading scales for meibography images. Cornea 2005;24(4):382-8. CR - Shimazaki J, Goto E, Ono M, Shimmura S, Tsubota K. Meibomian gland dysfunction in patients with Sjögren syndrome. Ophthalmology 1998;105(8):1485-8. CR - Goto E, Monden Y, Takano Y, et al. Treatment of noninflamed obstructive meibomian gland dysfunction by an infrared warm compression device. Br J Ophthalmol 2002;86(11):1403-7. CR - McCann LC, Tomlinson A, Pearce EI, Diaper C. Tear and meibomian gland function in blepharitis and normals. Eye Contact Lens 2009;35(4):203-8. CR - McCulley JP, Shine WE, Aronowicz J, Oral D, Vargas J. Presumed hyposecretory/hyperevaporative KCS: Tear characteristics. Trans Am Ophthalmol Soc 2003;101(3):141-52. CR - Aronowicz JD, Shine WE, Oral D, Vargas JM, McCulley JP. Short term oral minocycline treatment of meibomianitis. Br J Ophthalmol 2006;90(7):856-60. CR - Jester JV, Rife L, Nii D, Luttrull JK, Wilson L, Smith RE. In vivo biomicroscopy and photography of meibomian glands in a rabbit model of meibomian gland dysfunction. Invest Ophthalmol Vis Sci 1982;22(5):660-7. CR - Den S, Shimizu K, Ikeda T, Tsubota K, Shimmura S, Shimazaki J. Association between meibomian gland changes and aging, sex, or tear function. Cornea 2006;25(6):651-5. CR - Arita R, Itoh K, Inoue K, Amano S. Noncontact infrared meibography to document age-related changes of the meibomian glands in a normal population. Ophthalmology 2008;115(5):911-5. CR - Srinivasan S, Menzies K, Sorbara L, Jones L. Infra-red imaging of meibomian gland structure using a novel keratograph. OptomVis Sci 2012;89(5):788-94. CR - Henriquez AS, Korb DR. Meibomian glands and contact lens wear. Br J Ophthalmol 1981;65(2):108-11. CR - Ong BL. Relation between contact lens wear and meibomian gland dysfunction. Optom Vis Sci 1996;73(3):208-10. CR - Efron N, Jones L, Bron AJ, et al. The TFOS International Workshop on Contact Lens Discomfort: Report of the contact lens interactions with the ocular surface and adnexa subcommittee. Invest Ophthalmol Vis Sci 2013;54(11):98-122. UR - https://doi.org/10.19161/etd.416656 L1 - https://dergipark.org.tr/en/download/article-file/459895 ER -