<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>anatomy</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Anatomy</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">1308-8459</issn>
                                                                                            <publisher>
                    <publisher-name>Society of Anatomy and Clinical Anatomy</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id/>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Surgery (Other)</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Cerrahi (Diğer)</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                        <article-title>White to white cornea diameter and mesopic pupil size in patients with keratoconus</article-title>
                                                                                                                                        </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-7153-2950</contrib-id>
                                                                <name>
                                    <surname>Özçelik</surname>
                                    <given-names>Ferah</given-names>
                                </name>
                                                                    <aff>Beyoğlu Eye Training and  Research Hospital</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-4502-4423</contrib-id>
                                                                <name>
                                    <surname>Yılmaz</surname>
                                    <given-names>Tolga</given-names>
                                </name>
                                                                    <aff>Beyoğlu Eye Training and  Research Hospital</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0003-4052-7280</contrib-id>
                                                                <name>
                                    <surname>Gümüş</surname>
                                    <given-names>Güneş</given-names>
                                </name>
                                                                    <aff>Beyoğlu Eye Training and Research Hospital</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20221220">
                    <day>12</day>
                    <month>20</month>
                    <year>2022</year>
                </pub-date>
                                        <volume>16</volume>
                                        <issue>3</issue>
                                        <fpage>159</fpage>
                                        <lpage>164</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20220524">
                        <day>05</day>
                        <month>24</month>
                        <year>2022</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20221205">
                        <day>12</day>
                        <month>05</month>
                        <year>2022</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 2007, Anatomy</copyright-statement>
                    <copyright-year>2007</copyright-year>
                    <copyright-holder>Anatomy</copyright-holder>
                </permissions>
            
                                                                                                <abstract><p>Objectives: Keratoconus is characterized by the abnormal cornea structure and it is manifested by changes in anterior segment parameters responsible for ocular high order spherical aberrations. The aim of the study is to investigate cornea horizontal white to white diameter and mesopic pupil size in patients with keratoconus. Methods: The medical records of each participant were reviewed. The horizontal white to white cornea diameter and the mesopic pupil size were measured with the Sirius Topography System in 215 eyes of 123 subjects. Two groups were formed, the first group included 113 eyes with keratoconus and the second group is composed of 102 healthy eyes. Differences in sex, age, cornea diameter and mesopic pupil size between two groups were analyzed statistically. Results: There were no statistically significant differences in sex and age distribution between the two groups (p&amp;gt;0.05). The average horizontal corneal diameter was 11.98±0.33 mm in the 1st group and 11.81±0.24 mm in group 2. It was significantly higher in patients with keratoconus than in healthy subjects. (p=0.04) The mean mesopic pupil size was 3.64±0.12 mm in group 1 and it was 3.73±0.14 mm in group 2. The mesopic pupil size was significantly higher in healthy subjects than in patients with keratoconus (p=0.03). Conclusion: This study showed that while the horizontal white to white diameter of the cornea increases in keratoconus, the mesopic pupil size decreases. In clinical practice, these two parameters should be considered in treatment procedures of patients with keratoconus.</p></abstract>
                                                                                    
            
                                                            <kwd-group>
                                                    <kwd>cornea topography</kwd>
                                                    <kwd>  horizontal cornea diameter</kwd>
                                                    <kwd>  keratoconus</kwd>
                                                    <kwd>  mesopic pupil size</kwd>
                                            </kwd-group>
                                                        
                                                                                                                                                    </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">Baumeister M, Terzi E, Ekici Y, Kohnen T. Comparison of manual and automated methods to determine horizontal corneal diameter. J Cataract Refract Surg 2004;30:374–80.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">Rüfer F, Schröder A, Erb C. White-to-white corneal diameter: normal values in healthy humans obtained with the Orbscan II topography system. Cornea 2005;24:259–61.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">De Silva DJ, Khaw PT, Brookes JL. Long term outcome of primary congenital glaucoma. JAAPOS 2011;15:148–52.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">Allemann N, Chamon W, Tanaka HM, Mori ES, Campos M, Schor P, Baikoff G. Myopic angle-supported intraocular lenses: two-year follow-up. Ophtalmology 2000;107:1549–54.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">Rosen E, Gore C. Staar collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia. J Cataract Refract Surg 1998;24:596–606.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">Paryani MJ, Kharbanda V, Kummelil MK, Wadia K, Darak AB. Pupillodynamics and corneal spherical aberrations in a set of Indian cataract patients and its implications for aberrometric customisation of intraocular lenses. Indian J Ophthalmol 2020;68:3012–5.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">Haw WW, Manche EE. Effect of preoperative pupil measurements on glare, halos, and visual function after photoastigmatic refractive keratectomy. J Cataract Refract Surg 2001;27:907–15.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">Cakmak HB, Cagil N, Simavli H, Raza S. Corneal white-to-white distance and mesopic pupil diameter. Int J Ophthalmol 2012;5:505–9.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Galvis V, Sherwin T, Tello A, Merayo J, Barrera R, Acera A. Keratoconus: an inflammatory disorder? Eye (Lond) 2015;29:843–59.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">Rabinowitz YS. Keratoconus. Surv Ophthalmol 1998;42:297–319.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">Miháltz K, Kovács I, Kránitz K, Erdei G, Németh J, Nagy ZZ. Mechanism of aberration balance and the effect on retinal image quality in keratoconus: optical and visual characteristics of keratoconus. J Cataract Refract Surg 2011;37:914–22.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">Hashemia H, Khabazkhooba M, Emamianb MH, Shariatic M, Yektad A, Fotouhie A. White-to-white corneal diameter distribution in an adult population. J Curr Ophthalmol 2015;27:21–4.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">Hashemi H, Khabazkhoob M, Yazdani K, Mehravaran S, Mohammad K, Fotouhi A. White-to-white corneal diameter in the Tehran eye study. Curr Eye Res 2009;34:378–85.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Wang L, Auffarth GU. White-to-white corneal diameter measurements using the eyemetrics program of the Orbscan topography system. Dev Ophthalmol 2002;34:141–6.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">Seitz B, Langenbucher A, Zagrada D, Budde W, Kus M. Corneal dimensions in patients with various types of corneal dystrophies and their impact on penetrating keratoplasty [Article in German]. Klin Monbl Augenheilkd 2000;217:152–8.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">Sanchis-Gimeno JA, Sanchez-Zuriaga D, Martinez-Soriano F. White-to-white corneal diameter, pupil diameter, central corneal thickness and thinnest corneal thickness values of emmetropic subjects. Surg Radiol Anat 2012;34:167–70.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">Lee DW, Kim JM, Choi CY, Shin D, Park KH, Cho JG. Age-related changes of ocular parameters in Korean subjects. Clin Ophthalmol 2010;4:725–30.</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">Sulutvedt U, Zavagno D, Lubell J, Leknes S, de Rodez Benavent SA, Laeng B. Brightness perception changes related to pupil size.Vision Res 2021;178:41–7.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">Guler Alis M, Alis AJ. Compatibility of pupil size measured with Nidek ARK-1a table top autorefractometer and Plusoptix A12C photoscreene. J Binocul Vis Ocul Motil 2021;71:161–6.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">Mathot S, Fabius J, Heusden EV, Van der Stigchel S. Safe and sensible preprocessing and baseline correction of pupil-size data. Behav Res Methods 2018;50:94–106.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">Guillon M, Dumbleton K, Theodoratos P, Gobbe M, Wooley CB, Moody K. The effects of age, refractive status, and luminance on pupil size. Optom Vis Sci 2016;93:1093–100.</mixed-citation>
                    </ref>
                                    <ref id="ref22">
                        <label>22</label>
                        <mixed-citation publication-type="journal">Cakmak HB, Cagil N, Simavli H, Duzen B, Simsek S. Refractive error may influence mesopic pupil size. Curr Eye Res 2010;35:130–6.</mixed-citation>
                    </ref>
                                    <ref id="ref23">
                        <label>23</label>
                        <mixed-citation publication-type="journal">Netto MV, Ambrosio Jr R, Wilson SE. Pupil size in refractive surgery candidates. J Refract Surg 2004;20:337–42.</mixed-citation>
                    </ref>
                                    <ref id="ref24">
                        <label>24</label>
                        <mixed-citation publication-type="journal">Biçer GY, Zor KR, Küçük E. Do static and dynamic pupillary parameters differ according to childhood, adulthood, and old age? A quantitative study in healthy volunteers. Indian J Ophthalmol 2022;70:3575–8.</mixed-citation>
                    </ref>
                                    <ref id="ref25">
                        <label>25</label>
                        <mixed-citation publication-type="journal">Linke SJ, Baviera J, Munzer G, Fricke OH, Richard G, Katz T. Mesopic pupil size in a refractive surgery population (13,959 eyes). Optom Vis Sci 2012;89:1156–64.</mixed-citation>
                    </ref>
                                    <ref id="ref26">
                        <label>26</label>
                        <mixed-citation publication-type="journal">Tekin K, Sekeroglu MA, Kiziltoprak H, Doguizi S, Inanc M, Yilmazbas P. Static and dynamic pupillometry data of healthy individuals. Clin Exp Optom 2018;101:659–65.</mixed-citation>
                    </ref>
                                    <ref id="ref27">
                        <label>27</label>
                        <mixed-citation publication-type="journal">Birren J, Casperson R J. Age changes in pupil size. J Gerontol 1950;5:216–21.</mixed-citation>
                    </ref>
                                    <ref id="ref28">
                        <label>28</label>
                        <mixed-citation publication-type="journal">Kiel M, Grabitz SD, Hopf S, Koeck T, Wild PS, Schmidtmann I, Lackner KJ, Munzel T, Manfred E. Beutel ME, Pfeiffer N, Alexander K, Schuster AK. Distribution of pupil size and associated factors: results from the population-based gutenberg health study. J Ophthalmol 2022;9:9520512.</mixed-citation>
                    </ref>
                                    <ref id="ref29">
                        <label>29</label>
                        <mixed-citation publication-type="journal">Alarcón A, Rubiño M, Pééérez-Ocón F, Jiménez JR. Theoretical analysis of the effect of pupil size, initial myopic level, and optical zone on quality of vision after corneal refractive surgery. J Refract Surg 2012;28:901–6.</mixed-citation>
                    </ref>
                                    <ref id="ref30">
                        <label>30</label>
                        <mixed-citation publication-type="journal">Lee YS, Kim HJ, Lim DK, Kim MH, Lee KJ. Age-specific influences of refractive error and illuminance on pupil diameter. Medicine (Baltimore) 2022;101:e29859.</mixed-citation>
                    </ref>
                                    <ref id="ref31">
                        <label>31</label>
                        <mixed-citation publication-type="journal">Hondur G, Cagil N, Sarac O, Ozcan ME, Kosekahya P. Pupillary offset in keratoconus and its relationship with clinical and topographical features. Curr Eye Res 2017;42:708–12.</mixed-citation>
                    </ref>
                                    <ref id="ref32">
                        <label>32</label>
                        <mixed-citation publication-type="journal">Mihaltz K, Kranitz K, Kovacs I, Takács A, Németh J, Nagy ZZ. Shifting of the line of sight in keratoconus measured by a hartmann-shack sensor. Ophthalmology 2010;117:41–8.</mixed-citation>
                    </ref>
                                    <ref id="ref33">
                        <label>33</label>
                        <mixed-citation publication-type="journal">Schmitz S, Krummenauer F, Henn S, Dick HB. Comparison of three different technologies for pupil diameter measurement. Graefes Arch Clin Exp Ophthalmol 2003;241:472–7.</mixed-citation>
                    </ref>
                                    <ref id="ref34">
                        <label>34</label>
                        <mixed-citation publication-type="journal">Fernández-Velázquez F. Performance and predictability of a new large diameter contact lens design in keratoconic corneae. Cont Lens Anterior Eye 2019;42:289–94.</mixed-citation>
                    </ref>
                                    <ref id="ref35">
                        <label>35</label>
                        <mixed-citation publication-type="journal">Seitz B, Langenbucher A, Zagrada D, Budde W, Kus MM. Corneal dimensions in various types of corneal dystrophies and their effect on penetrating keratoplasty [Article in German]. Klin Monbl Augenheilkd 2000;217:152–8.</mixed-citation>
                    </ref>
                                    <ref id="ref36">
                        <label>36</label>
                        <mixed-citation publication-type="journal">Monsálvez-Romín D, González-Méijome JM, Esteve-Taboada JJ, García-Lázaro S, Cerviño A. Light distortion of soft multifocal contact lenses with different pupil size and shape. Cont Lens Anterior Eye 2020;43:130–6.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>
