Research Article
BibTex RIS Cite
Year 2023, Volume: 2 Issue: 1, 114 - 119, 13.12.2023

Abstract

Project Number

TKP-2020-1766

References

  • [1] Wallace S, McGrath BA. Laryngeal complications after tracheal intubation and tracheostomy. BJA Educ. 2021; 21(7): 250–257
  • [2] Del Negro MS, Barreto G, Antonelli RQ, Baldasso TA, Meireles LR, Moreira MM, Tincani AJ. Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects. Rev Bras Cir Cardiovasc. 2014; 29(4): 552–558
  • [3] Bone DK, Davis LJ, Zuidema DG, Cameron JL. Aspiration Pneumonia: Prevention of Aspiration in Patients with Tracheostomies. The Annals of Thoracic Surgery. 1974; 18(1):30-37
  • [4] Dongho S, Gerald L, Lin RJ. In-hospital mortality for aspiration pneumonia in a tertiary teaching hospital: A retrospective cohort review from 2008 to 2018. Journal of Otolaryngology - Head & Neck Surgery. 2023; 52(23):4425-30
  • [5] Smith, J. et al. The Importance of Tracheostomy in Critical Care: A Comprehensive Review. Journal of Intensive Care Medicine. 2019; 45(2): 87-95
  • [6] Johnson, A. et al. Complications and Challenges Associated with Cuffed Tracheostomy Cannulas: A Retrospective Study. Critical Care Nursing Journal. 2020; 55(4): 212-225
  • [7] Anderson, L. et al. An Automated System for Managing Cuffed Tracheostomy Cannulas in Intensive Care: A Novel Approach. Medical Engineering and Technology Journal. 2022; 70(6): 324-35
  • [8] Garcia, E. et al. The Impact of an Automated System on Reducing Aspiration Pneumonia Incidence in Tracheostomy Patients: Preliminary Findings. Healthcare Innovation Research Journal. 2023; 75(2)88-101

DESIGN AND DEVELOPMENT OF A PROTOTYPE OF PROGRAMMABLE TRACHEOSTOMY CANNULA THAT CAN PERFORM OVER-CUFF SUCTION FOR USE IN INTENSIVE CARE PATIENTS WITH DYSPHAGIA

Year 2023, Volume: 2 Issue: 1, 114 - 119, 13.12.2023

Abstract

One of the most important risks in patients with respiratory device-related dysphagia is aspiration pneumonia. Since these patients do not have a swallowing reflex, secretions flowing from the mouth and nose area into the trachea accumulate on the cuff, creating a suitable environment for bacterial growth and causing pneumonia to develop in the patient. One of the most important risks in patients with respiratory device-related dysphagia is aspiration pneumonia. Since these patients do not have a swallowing reflex, secretions flowing from the mouth and nose area into the trachea accumulate on the cuff, creating a suitable environment for bacterial growth and causing pneumonia to develop in the patient. Currently, suctioning of these patients is performed manually by nurses. However, manual aspiration cannot provide disinfection at the desired level and cannot be performed as often as desired. In this study, a tracheostomy cannula prototype that can perform spontaneous cuff washing and aspiration was developed to eliminate these problems.

Ethical Statement

The study does not require any ethics committee approval.

Supporting Institution

Scientific Research Projects Coordination Unit of İnönü University

Project Number

TKP-2020-1766

Thanks

Scientific Research Projects Coordination Unit of İnönü University

References

  • [1] Wallace S, McGrath BA. Laryngeal complications after tracheal intubation and tracheostomy. BJA Educ. 2021; 21(7): 250–257
  • [2] Del Negro MS, Barreto G, Antonelli RQ, Baldasso TA, Meireles LR, Moreira MM, Tincani AJ. Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects. Rev Bras Cir Cardiovasc. 2014; 29(4): 552–558
  • [3] Bone DK, Davis LJ, Zuidema DG, Cameron JL. Aspiration Pneumonia: Prevention of Aspiration in Patients with Tracheostomies. The Annals of Thoracic Surgery. 1974; 18(1):30-37
  • [4] Dongho S, Gerald L, Lin RJ. In-hospital mortality for aspiration pneumonia in a tertiary teaching hospital: A retrospective cohort review from 2008 to 2018. Journal of Otolaryngology - Head & Neck Surgery. 2023; 52(23):4425-30
  • [5] Smith, J. et al. The Importance of Tracheostomy in Critical Care: A Comprehensive Review. Journal of Intensive Care Medicine. 2019; 45(2): 87-95
  • [6] Johnson, A. et al. Complications and Challenges Associated with Cuffed Tracheostomy Cannulas: A Retrospective Study. Critical Care Nursing Journal. 2020; 55(4): 212-225
  • [7] Anderson, L. et al. An Automated System for Managing Cuffed Tracheostomy Cannulas in Intensive Care: A Novel Approach. Medical Engineering and Technology Journal. 2022; 70(6): 324-35
  • [8] Garcia, E. et al. The Impact of an Automated System on Reducing Aspiration Pneumonia Incidence in Tracheostomy Patients: Preliminary Findings. Healthcare Innovation Research Journal. 2023; 75(2)88-101
There are 8 citations in total.

Details

Primary Language English
Subjects Biomedical Instrumentation
Journal Section Research Articles
Authors

Kadir Batçıoğlu 0000-0001-6663-2287

Mehmet Tecellioglu This is me 0000-0002-8381-9630

Project Number TKP-2020-1766
Publication Date December 13, 2023
Submission Date November 8, 2023
Acceptance Date November 30, 2023
Published in Issue Year 2023 Volume: 2 Issue: 1

Cite

EndNote Batçıoğlu K, Tecellioglu M (December 1, 2023) DESIGN AND DEVELOPMENT OF A PROTOTYPE OF PROGRAMMABLE TRACHEOSTOMY CANNULA THAT CAN PERFORM OVER-CUFF SUCTION FOR USE IN INTENSIVE CARE PATIENTS WITH DYSPHAGIA. Anatolian Journal of Pharmaceutical Sciences 2 1 114–119.