The effect of tenoxicam on bone repair in the femur of 20 Sprague-Dawley rats (10 control, 10 test) after hole injury was studied using biomechanical methods. The test group received 8 mg/kg/day of tenoxicam until the rats were sacrificed on the 21st postoperative day. The torsional strength of the femur (n=32) and the intact tibia (n=32) was measured as the maximum torque capacity in 16 rats. The torsional strengths were as follows: femur control group 0.342 ± 0.061 Nm, test group 0.275 ± 0.037 Nm (p=0.060); tibia control group 0.130 ± 0.021 Nm, test group 0.118 ± 0.043 Nm (p=0.519) . Tenoxicam had no statistically significant effect upon the torsional strength of the femora with hole injury and the intact tibiae (p<0.05)
Tenoksikam'ın kemik iyileşmesi üzerine etkisini 20 Sprague-Dawley sıçanın (10 deney, W kontrol) femurunda defekt oluşturarak, değerlendirmeye alınan 16'sında biyomekanik yöntemlerle araştırdık. Deney grubuna 8 mg/kg/gün tenoksikam verildi. Sıçanlar 21. günde sakrifiye edildi. Defektli femur (n=32) ve intakt tibiaların (n=32) torsiyonel dayanımı maksimum terk kapasitesi olarak ölçüldü. Torsiyonel dayanım femur için kontrol grubunda 0.342±0.061 Nm, deney grubunda 0.275 ± 0.037 Nm (p=0.060): tibia için kontrol grubunda 0.130 ± 0.021 Nm, deney grubunda 0.118 ± 0.043 Nm (p=0.519) bulundu. Tenoksikamın defektli femur ve intakt tibiaların torsiyonel dayanımı üzerine istatistiksel açıdan anlamlı bir etkisi olmadı (p<0.05).
Primary Language | English |
---|---|
Journal Section | Experimental Study |
Authors | |
Publication Date | September 11, 2006 |
Published in Issue | Year 1997 Volume: 31 Issue: 1 |