BibTex RIS Cite

Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study

Year 2001, Volume: 35 Issue: 2, 169 - 174, 11.09.2006

Abstract

Objectives: This study was designed to compare the primary fixation strength of transosseous sutures and suture anchors in rotator cuff repair.
Methods: Thirty-two sheep shoulders were divided into four homogeneously equal groups. In each group, infraspinatus tendons were cut from their insertions and reattached with four diverse techniques, which included a single Mason-Allen stitch (group 1), double Mason-Allen stitches (group 2), double Mason-Allen stitches knotted on the lateral cortex followed by augmentation with a mini metal plate (group 3), and two Corkscrew suture anchors (Arthrex, Germany) (group 4). All specimens were tested for fixation strengths with a Material Testing System machine. Statistical analyses were made using one-way ANOVA and LSD post hoc tests.
Results: The mean failure load values were 160.31±34.59 N, 199.36±11.73 N, 182.35±19.19 N, and 108.32±15.98 N in groups 1, 2, 3, and 4, respectively (ANOVA, F=24.63, p<0.001). It was found that group 4 was significantly weaker than the other groups (p<0.001), that the strength of the transosseous suture improved with double sutures (group 1 vs group 2 p=0.002), and that augmentation of the lateral cortex with a metal plate did not improve strength (group 1 vs group 3, p=0.07).
Conclusion: We concluded that rotator cuff fixation with only suture anchors cannot provide a reliable strength and that fixation must include multiple sutures if only transoosseous sutures are to be used.

Transosseöz dikiş ve dikiş ankorlar ile rotator manşet tamirlerinin karşılaştırılması: Biyomekanik deneysel çalışma

Year 2001, Volume: 35 Issue: 2, 169 - 174, 11.09.2006

Abstract

Amaç: Bu çalışma rotator manşet cerrahisinde değişik transosseöz dikiş teknikleri ve dikiş ankorlarını biyomekanik olarak karşılaştırmak amacıyla planlandı.
Çalışma planı: Otuz iki adet yeni kesilmiş koyun omzu, her birinde sekizer adet olmak üzere homojen olarak dört gruba ayrıldı. Humerustan total olarak ayrılan infraspinatus tendonları, dört farklı yöntemle tamir edildi. Tamirler grup 1’de tek Mason-Allen dikişi ile, grup 2’de iki Mason-Allen dikişi ile yapıldı. Grup 3’te kemik tünellerin lateral korteksteki uçlarının arasındaki köprü, plak ile desteklendi. Grup 4’te iki adet Corkscrew ankor ile tamir yapıldı. Kemik-tendon tamir kompleksine, materyal test cihazında gerilme deneyi uygulandı ve en yüksek dayanma kuvveti belirlendi. İstatistiksel analizler tek yönlü ANOVA testi ve LSD post hoc ile yapıldı.
Sonuçlar: Ortalama en yüksek dayanma kuvvetleri gruplarda sırasıyla 160.31±34.59 N, 199.36±11.73 N, 182.35±19.19 N ve 108.32±15.98 N bulundu (ANOVA, F=24.63, p<0.001). Grup 4’ün diğer üç gruptan çok anlamlı olarak daha zayıf bir tespit yöntemi olduğu görüldü (p<0.001). Transosseöz dikiş tekniğinde dikiş sayısının artırılması ile dayanıklılık artarken (grup 1-grup 2, p=0.002), lateral kortekste plak uygulanması ile anlamlı derecede destek sağlanmadığı (grup 1-grup 3, p=0.07) gözlendi.
Çıkarımlar: Sadece ankorla tespitin yeterince güvenilir olmadığı ve stabilitesinin artırılması gerektiği; ayrıca transosseöz dikiş tekniğinde de dikiş sayısının artırılması gerektiği sonucuna varıldı.

There are 0 citations in total.

Details

Primary Language English
Journal Section Experimental Study
Authors

Ata Atalar This is me

Mehmet Demirhan This is me

Ergun Bozdag This is me

Yilmaz Akalin This is me

Alaeddin Arpaci This is me

Publication Date September 11, 2006
Published in Issue Year 2001 Volume: 35 Issue: 2

Cite

APA Atalar, A., Demirhan, M., Bozdag, E., Akalin, Y., et al. (2006). Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study. Acta Orthopaedica Et Traumatologica Turcica, 35(2), 169-174. https://doi.org/10.3944/aott.v35i2.1716
AMA Atalar A, Demirhan M, Bozdag E, Akalin Y, Arpaci A. Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study. Acta Orthopaedica et Traumatologica Turcica. September 2006;35(2):169-174. doi:10.3944/aott.v35i2.1716
Chicago Atalar, Ata, Mehmet Demirhan, Ergun Bozdag, Yilmaz Akalin, and Alaeddin Arpaci. “Comparison of Transosseous Suture and Suture Anchors in the Fixation of Rotator Cuff Tears: A Biomechanical Experimental Study”. Acta Orthopaedica Et Traumatologica Turcica 35, no. 2 (September 2006): 169-74. https://doi.org/10.3944/aott.v35i2.1716.
EndNote Atalar A, Demirhan M, Bozdag E, Akalin Y, Arpaci A (September 1, 2006) Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study. Acta Orthopaedica et Traumatologica Turcica 35 2 169–174.
IEEE A. Atalar, M. Demirhan, E. Bozdag, Y. Akalin, and A. Arpaci, “Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study”, Acta Orthopaedica et Traumatologica Turcica, vol. 35, no. 2, pp. 169–174, 2006, doi: 10.3944/aott.v35i2.1716.
ISNAD Atalar, Ata et al. “Comparison of Transosseous Suture and Suture Anchors in the Fixation of Rotator Cuff Tears: A Biomechanical Experimental Study”. Acta Orthopaedica et Traumatologica Turcica 35/2 (September 2006), 169-174. https://doi.org/10.3944/aott.v35i2.1716.
JAMA Atalar A, Demirhan M, Bozdag E, Akalin Y, Arpaci A. Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study. Acta Orthopaedica et Traumatologica Turcica. 2006;35:169–174.
MLA Atalar, Ata et al. “Comparison of Transosseous Suture and Suture Anchors in the Fixation of Rotator Cuff Tears: A Biomechanical Experimental Study”. Acta Orthopaedica Et Traumatologica Turcica, vol. 35, no. 2, 2006, pp. 169-74, doi:10.3944/aott.v35i2.1716.
Vancouver Atalar A, Demirhan M, Bozdag E, Akalin Y, Arpaci A. Comparison of transosseous suture and suture anchors in the fixation of rotator cuff tears: a biomechanical experimental study. Acta Orthopaedica et Traumatologica Turcica. 2006;35(2):169-74.