BibTex RIS Cite

Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)

Year 1981, Volume: 15 Issue: 4, 211 - 237, 20.11.1981

Abstract

In this study, attempts have been made to relate the altered biomechanic following total endoprosthetic application in the hip joint. Both the surgical procedure and the choice of material considerabiy affect the life and durability of the prosthesis in the application of total endoprosthesis. For instance, it is imperative that the length of the neck of the prosthesis should not exceed 35 mm and the CCD angle of the prosthesis should not be less than 140. Furthermore. The femoral varus deformity has been described to be the latent factor in increasing the bending moment and predisposing the loosening.

TOTAL ENDOPROTEZ UYGULAMASINDAN SONRA KALÇA EKLEMİNİN BİYOMEKANİK SORUNLARI (FEMUR VARUM DEFORMİTESİNİN GEVŞEME YÖNÜNDEN ÖNEMİ)

Year 1981, Volume: 15 Issue: 4, 211 - 237, 20.11.1981

Abstract

Bu çalışmada, kalça ekleminin total endoprotez uygulamasından sonra değişen biyomekaniği ele alınmıştır. Total endoprotez uygulamasında gerek ameliyat tekniği, gerekse materiyal seçimi, protezin ömrünü ve dayanıklılığını önemli derecede etkilemektedir. Örneğin, protez boynunun 35 mm den uzun, protezin CCD açısının 140 dereceden küçük olmaması gerekmektedir. Ayrıca femur varum deformitesi, bükülme momentini arttırıcı ve gevşemeyi hazırlayıcı latent faktör olarak tanımlanmıştır.

There are 0 citations in total.

Details

Primary Language English
Journal Section Original Article
Authors

M. Yucel This is me

Publication Date November 20, 1981
Published in Issue Year 1981 Volume: 15 Issue: 4

Cite

APA Yucel, M. (1981). Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica Et Traumatologica Turcica, 15(4), 211-237. https://doi.org/10.3944/aott.v15i4.3200
AMA Yucel M. Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica. November 1981;15(4):211-237. doi:10.3944/aott.v15i4.3200
Chicago Yucel, M. “Biomechonical Problems Encountered in the Hip Joint Following the Applicational Total endoprosthesis (Significance of the Femoral Varus Deformity in Respect of Proshetic Bosening)”. Acta Orthopaedica Et Traumatologica Turcica 15, no. 4 (November 1981): 211-37. https://doi.org/10.3944/aott.v15i4.3200.
EndNote Yucel M (November 1, 1981) Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica 15 4 211–237.
IEEE M. Yucel, “Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)”, Acta Orthopaedica et Traumatologica Turcica, vol. 15, no. 4, pp. 211–237, 1981, doi: 10.3944/aott.v15i4.3200.
ISNAD Yucel, M. “Biomechonical Problems Encountered in the Hip Joint Following the Applicational Total endoprosthesis (Significance of the Femoral Varus Deformity in Respect of Proshetic Bosening)”. Acta Orthopaedica et Traumatologica Turcica 15/4 (November 1981), 211-237. https://doi.org/10.3944/aott.v15i4.3200.
JAMA Yucel M. Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica. 1981;15:211–237.
MLA Yucel, M. “Biomechonical Problems Encountered in the Hip Joint Following the Applicational Total endoprosthesis (Significance of the Femoral Varus Deformity in Respect of Proshetic Bosening)”. Acta Orthopaedica Et Traumatologica Turcica, vol. 15, no. 4, 1981, pp. 211-37, doi:10.3944/aott.v15i4.3200.
Vancouver Yucel M. Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica. 1981;15(4):211-37.