<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article         dtd-version="1.4">
            <front>

                <journal-meta>
                                    <journal-id></journal-id>
            <journal-title-group>
                                                                                    <journal-title>Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi</journal-title>
            </journal-title-group>
                            <issn pub-type="ppub">1300-9044</issn>
                                        <issn pub-type="epub">2667-5161</issn>
                                                                                            <publisher>
                    <publisher-name>Ataturk University</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id/>
                                                                                                                                                                                            <title-group>
                                                                                                                        <article-title>İMPLANT TEDAVİSİNDE BİLGİSAYARLI TOMOGRAFİ DESTEKLİ CERRAHİ KILAVUZLARIN KULLANIMI</article-title>
                                                                                                                                                                                                <trans-title-group xml:lang="en">
                                    <trans-title>THE USE OF COMPUTED TOMOGRAPHY SUPPORTED SURGICAL GUIDES IN DENTAL IMPLANT TREATMENT</trans-title>
                                </trans-title-group>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                <name>
                                    <surname>Akova</surname>
                                    <given-names>Yrd. Doç. Dr. Tolga</given-names>
                                </name>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                <name>
                                    <surname>Üstün</surname>
                                    <given-names>Yrd. Doç. Dr. Yakup</given-names>
                                </name>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20060201">
                    <day>02</day>
                    <month>01</month>
                    <year>2006</year>
                </pub-date>
                                        <volume>2006</volume>
                                        <issue>2</issue>
                                        <fpage>16</fpage>
                                        <lpage>21</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20140421">
                        <day>04</day>
                        <month>21</month>
                        <year>2014</year>
                    </date>
                                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1986, Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi</copyright-statement>
                    <copyright-year>1986</copyright-year>
                    <copyright-holder>Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi</copyright-holder>
                </permissions>
            
                                                                                                <abstract><p>Günümüzde di sizliklerin tedavisinde implant üstü restorasyonlar n kullan m oldukça yayg n hale gelmi tir. Klinik ba ar n n elde edilmesinde implantlar nlokalizasyonlar ve ba ar l bir ekilde yerle tirilmesi büyük önem ta maktad r. Estetik ve fonksiyonel olarak hastalar n memnuniyetinin sa3lanmas için yap lacak protetik giri imler ancak iyi bir implant yerle imi sa3lanm sa mümkün olabilir. 5mplant cerrahisinde protetik rehabilitasyonu gerçekle tirecek olan hekimin haz rlayaca3 cerrahi k lavuzlar ba ar l bir sonuç elde edilmesini sa3layacakt r. Geli en teknoloji ile birlikte bilgisayarlmodellerin elde edilmesi ve kullan lan özgün yaz l mlar ile bu modellerde cerrahi k lavuzlar n haz rlanmas hem cerrah n implantlar yerle tirmesinde kolayl k sa3layacak hem de restoratif di hekiminin hasta beklentilerine uygun bir restorasyon yapmas n sa3layacakt r. Bu derlemede bilgisayarl tomografi destekli implant planlamas , üç boyutlu model elde edilmesi ve cerrahi k lavuzlar n kullan m anlat lmaktad r. Günümüzde bu yakla m maliyet aç s ndan s k nt l ve uygulanabilirli3ik s tl gibi görünse de ba ar l bir planlama, operasyon süresini k saltmas , estetik ve fonksiyonel ba ar l bir protezin yap labilmesine olanak sa3lamas aç s ndan özellikle karma k vakalarda hem cerrah n hem de protetik rehabilitasyonu yapacak restoratif hekimin çok faydalanabilece3i bir uygulamad r</p></abstract>
                                                                                    
            
                                                            <kwd-group>
                                                    <kwd>-</kwd>
                                            </kwd-group>
                                                        
                                                                            <kwd-group xml:lang="en">
                                                    <kwd>dental implant</kwd>
                                                    <kwd>   surgical guide</kwd>
                                                    <kwd>   computed tomography</kwd>
                                                    <kwd>   three-dimensional modeling</kwd>
                                                    <kwd>   implant planning</kwd>
                                            </kwd-group>
                                                                                                            </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">Tal H, Moses O.Comparison of panoramic radiography with computed tomography in the planning of implant surgery. Dentomaxillo-facial Radiology, 1991; 20:40-42.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">Murrapu M, Singer SR. Implant imaging for the dentist. J Can Dent Assoc, 2004; 70:32-32.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">Tschuida F, Hosoi T, Imanaka M, Kobayashi K. A technique for making a diagnostic and surgical template. J Prosthet Dent, 2004; 91: 395-7.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">Ikumi N, Tsutsumi S. Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study. Int J Oral Maxillofac Implants, 2005; 20: 253-260.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement : preliminary results. J Periodontol, 2005; 7: 503-507.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">Holmes PJ, Mller JR, Gutta R, Louis PJ. Intraoperative imaging techniques: a guide to retrieval of foreign bodies. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2005; 100:614618.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">Hounsfield GN. Computerized transverse axial scanning (tomography). Br J Radiol, 1973;46: 1016-1022.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">Helms C, Morrish R, Kircos LT. Computed tomography of the TMJ: preliminary considerations. Radiology, 1982; 141: 718-724.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Chiche GJ, Books MS, Pinault A. Implant surgical template for partially edentulous patients. Int J Oral Maxillofac Implants, 1989; 4:289-292.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">Kopp KC, Koslow AH, Abdo OS. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J Prosthet Dent, 2003; 89: 611-615.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">Brief J, Hassfeld S, Sonenfeld U, Persky N, Krempien R, Treiber M, Muhling J. Computer guided insertion of dental implants – a clinical evaluation . In :Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K. eds Computer Assisted Radiology and Surgey.Proceedings of the 15. International Symposium and Exhibition on Computer Assisted Radiology and Surgery, Elsevier, Tokyo, 2002b: 696-701.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">Homolka P, Beer A, Birkellner W, Nowotn R, Gahleitner A, Tschabitscher M, Bergmann. Bone mineral density measurement with quantitative CT prior the dental implant placement in cadaver mandible: pilot study. Radiology, 2002; 224: 247252.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">Casap N, Wexler A, Persky N, Schneider A, Lustmann J. Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system. J oral Maxillofac Surg, 2004; 62:116-119.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Miller RJ, Bier J. Surgical navigation in oral implantology. Implant Dent, 2006; 15: 41-47.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">Brief J, Edinger D, Hassfeld S, Eggers G. Accuray of image-guided implantology. Clin Oral Implants Res, 2005; 16: 495-501.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">Hoffmann J, Westerndorff C, Gomez-Roman G, Reinert S. Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a syntetic edentulous lower jaw model. Clin Oral Implants Res, 2005; 16:609-614.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">Widmann G, Widmann R, Widman E, Jaschke W, Bale RJ. In vitro accuracy of a novel and targeting technique for image guided template production. Clin Oral Implants Res, 2005; 16: 502-508.</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">Meitner SW, Tallents HR. Surgical templates for prosthetically guided implant placement. J Prosthet Dent, 2004; 92: 569-574.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">Plummer KD, Nahon M. Use of a reline jig to fabricate a complete denture implant surgical guide from an existing complete denture. J Prosthet Dent, 2004; 92 :598-599.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">Shotwell JL, Billy EJ, Wang HL, Oh Tae-JU. Implant surgical guide fabrication for partially edentulous patients. J Prosthet Dent, 2005; 93 : 294-297.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">Tsuhida F, Hosoi T, Imanaka M, Kobayashi K. a technique for making a diagnostic and surgical template. J Prosthet Dent, 2004; 91: 395-397.</mixed-citation>
                    </ref>
                                    <ref id="ref22">
                        <label>22</label>
                        <mixed-citation publication-type="journal">Berry J, O”Malley BW, Humphries S, Staecker H. Making image guidance work: understanding control of accuracy. Ann Otol Rhinol Laryngol , 2003; 112: 689-692.</mixed-citation>
                    </ref>
                                    <ref id="ref23">
                        <label>23</label>
                        <mixed-citation publication-type="journal">Stenmeier R, Rachinger j, Kaus M, Ganslandt O, Huk W, Fahlbusch R. Factors influencing the application accuracy of neuronavigation systems. Stereotact Funct Neurosurg, 2000; 75: 188-202.</mixed-citation>
                    </ref>
                                    <ref id="ref24">
                        <label>24</label>
                        <mixed-citation publication-type="journal">Hassfeld S, Streib S, Sahl H, Stratmann U, Fehrentz D, Zoller J. Low-dose-Computertomographie des Kieferknochens in der praimplantologischen Diagnostik. Mund -Kiefer-und Gesichtschirurgie, 1998; 2: 188-193.</mixed-citation>
                    </ref>
                                    <ref id="ref25">
                        <label>25</label>
                        <mixed-citation publication-type="journal">Diederichs CG, Engelke WGH, Richter B, Hermann KP, Oestmann J. Must radiation dose for CT of the maxilla and mandible be higher than that for conventional panoramic radiography?. Am J Neuroradiol, 1996; 17: 1758-1760.</mixed-citation>
                    </ref>
                                    <ref id="ref26">
                        <label>26</label>
                        <mixed-citation publication-type="journal">Fortin T, Isidori M, Blanchet E, Perriat M, Bouchet H, Coudert JL. An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. Clin Implant Dent Relat Res, 2004;6:111-119.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>
