<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                    <journal-id></journal-id>
            <journal-title-group>
                                                                                    <journal-title>Ankara Üniversitesi Tıp Fakültesi Mecmuası</journal-title>
            </journal-title-group>
                            <issn pub-type="ppub">0365-8104</issn>
                                        <issn pub-type="epub">1307-5608</issn>
                                                                                            <publisher>
                    <publisher-name>Ankara University</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id/>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Thoracic Surgery</subject>
                                                            <subject>Cardiovascular Surgery</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Göğüs Cerrahisi</subject>
                                                            <subject>Kalp ve Damar Cerrahisi</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                        <trans-title-group xml:lang="en">
                                    <trans-title>THROMBO - EMBOLIC COMPLICATIONS IN CASES OF MITRAL VALVE REPLACEMENT</trans-title>
                                </trans-title-group>
                                                                                                                                                                                                <article-title>Mitral Valv Replasmanı Yapılan Vakalarda Trombo - Embolik Komplikasyonlar</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                <name>
                                    <surname>Kural</surname>
                                    <given-names>Tuğrul</given-names>
                                </name>
                                                                    <aff>ANKARA UNIVERSITY, ANKARA FACULTY OF MEDICINE</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="19750630">
                    <day>06</day>
                    <month>30</month>
                    <year>1975</year>
                </pub-date>
                                        <volume>28</volume>
                                        <issue>1-2</issue>
                                        <fpage>598</fpage>
                                        <lpage>604</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="19750101">
                        <day>01</day>
                        <month>01</month>
                        <year>1975</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="19750630">
                        <day>06</day>
                        <month>30</month>
                        <year>1975</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1947, Ankara Üniversitesi Tıp Fakültesi Mecmuası</copyright-statement>
                    <copyright-year>1947</copyright-year>
                    <copyright-holder>Ankara Üniversitesi Tıp Fakültesi Mecmuası</copyright-holder>
                </permissions>
            
                                                                                                <trans-abstract xml:lang="en">
                            <p>Thromboembolism is one of the most important complications seen in mitral valve replacements. Today, the risk of thrombo - embolism in mitral valve replacements is between 2% and 63%. Our Starr- Edwards and Kay L-Shiley used artificial prosthesEs1e1 In our cases, this rate was 16%, although my patients were anticoagulated from the first postoperative day1r.  However, in Starr- Edwards model 6120 covers, thrombo embolism is less likely to occur than in Kay -Shiley covers. This complication is closely related to the structure, type of prosthesis used, and the patient&#039;s condition.</p></trans-abstract>
                                                                                                                                    <abstract><p>Tromboembolizm mitral kapak replasmanlarında görülen en önemli komplikasyonlardan biridir. Günümüzde mitral kapak replasmanlarında trombo - emboli riski% 2 ile% 63 arasındadır. Starr-Edwards ve Kay L-Shiley&#039;imiz yapay protez kullandı1e1 Olgularımızda bu oran% 16 idi, ancak hastalarım ameliyat sonrası ilk günden itibaren antikoagüle edildi1r. Ancak Starr-Edwards model 6120 kapaklarında trombo embolisinin oluşma olasılığı Kay-Shiley kapaklarına göre daha düşüktür. Bu komplikasyon, kullanılan protezin yapısı, tipi ve hastanın durumu ile yakından ilgilidir.</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>mitral valv</kwd>
                                                    <kwd>  tromboemboli</kwd>
                                                    <kwd>  cerrahi</kwd>
                                            </kwd-group>
                            
                                                <kwd-group xml:lang="en">
                                                    <kwd>MITRAL VALVE</kwd>
                                                    <kwd>  THROMO-EMBOLI</kwd>
                                                    <kwd>  surgery</kwd>
                                            </kwd-group>
                                                                                                                                    <funding-group specific-use="FundRef">
                    <award-group>
                                                    <funding-source>
                                <named-content content-type="funder_name">ankara üniversitesi tıp fakültesi</named-content>
                            </funding-source>
                                                                    </award-group>
                </funding-group>
                                </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">1	— Cooley, A. D., Bloodwell, R. D, Hallman, G. L. : Mitral valv replacement with a discoid prosthesis. Ann. Thorac. Surg., 3 : 487, 1967.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">2	Starr, A. : Mitral valv replacement with ball valv prosthesis Brit. Heart. J., Suppl. 1, 47 -55, 33 : 47, 1971.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">3	Donatelli, R., Respighi, E., Pellegrini, A, Mombeloni, G., Belloni, &#039;P. A., Santoli, C. : Mitral alv replacement. Gasetta Sanitaria XVIII : 163, 1969.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">4	— Bozer, A. Y., tligin, G. : AGIk kalp ameliyatl uygulanan 96 mitral valv hastasmda tedavi sonuçlan. A. t&#039;. TIP Fak. Mec. XXIII 1295, 1970.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">5	— Starr, A., Herr, R. H., Wood, J. A. : Mitral valv replacement review of six years experiens, J. Thorac. Cardiovasc. Surg. 54 : 333, 1967.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">6	— Najafl, H., Dye, W. S., Javid, H., Hunter, J. A., Ostermiller, W. n, Ormad, J. : Mitral valv replacement. Am. J. Cardiol., 24 : 386, 1969.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">7	— Matloff, J. M., Collins, J. R., Sullivan, J. M., Corling, R., Harken, D. E. : Control of trombo - embolism from prosthetic heart valves. Ann. Thorac. surg., 8 : 133, 1969.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">8	— Yeh, T. J., Anabtawi, T. N., Cornette, V. n, Ellison, R. G. : Influence of rhythm and anticoagulation upon the incidance of embolisation associated with Starr - Edwards prostheses, Circulation, 35 (Suppl 1), 77, 1967.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">9	— Morrow, A. G., Oldhon, H. N., Elkins, R. G., Braunwald, E. : Prosthetic replacement of mitral valv, Circulation. 35 : 962, 1967.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">10	— Rees, J. R., Hoswade, G. R, Lillehei, C W. : Patient status five 01&#039; more years after mitral valv replacement, Ann. Ann. Thorac. Surg., 14 : 31, 1972.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">11	— Joassin, A., Edwards, J. C. : Late causes of death after mitral valv replacement (Analysis of 36 case), J. Thorac. Cardiovasc. Surg., 65 : 255, 1973.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">12	— Firat, T., Bozer, A. Y. : ACIk kalp amcliyatmdan sonra görülen bir bilateral oftalmopleji ve hemipleji vak&#039;asl münasebeti ile : Türk Oftalmopleji gazetesi, vol : 3 (Vill) : 1 Ocak -Mart 1971.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">13	— Duvoising, G. E., Brandenburg, R. 0., McGoon, D. C. : Factors affecting tromboembolizm associated with prosthetic heart valves, Circulation 35 (Suppl 1) : 70, 1967.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">14	— Gadboys, H. L., Litwak, R. S., Niemetz, J., Wisch, N. : Role of antlcoagulants in preventing embolisation from prosthetic heart valves, J. A. M. A.. 202 : 184, 1967*</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">15	— Pate, J. W. : Trombosis on sutures varios cardiac chambers, Surgery, 55 : 291, 1964.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">16	— Böke, E., Bozer, A. Y. : Akkiz kalp kapak hastallklannda cerrahi tedavi ve uzun süreli takip sonuçlarl, A, Ü. TIP Fak. Mec. XXV : 371, 1972.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">17	Niles, N. R., Sandilands, JR. : Pathology of heart valv replacement surgery (Autopsies of 62 patients with Starr - Edwards prostheses) Dis. Chest, 56 : 373, 1969.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>
