BibTex RIS Cite

Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine

Year 2001, Volume: 4 Issue: 1, 53 - 60, 01.12.2000

Abstract

An ultrasonic device was calibrated to measure in situ and in real time the polyol ester oil (POE) concentration of the refrigerant liquid R 410A. The first part of this paper is devoted to the properties of the mixture, to the effects of the presence of oil on the speed of sound in the liquid phase and to the calibration and validation procedures carried out with a saturated liquid refrigerant. In order to have a number of calibration points that is not too large, it is necessary to maintain the mixture as close as possible to saturation conditions, which constrains the choice of the location of the sensor on the installation investigated. In the second part, the first results obtained on this installation are presented. It appears that the speed of sound in the POE / R 410A mixture is a strong function of the temperature and oil concentration, as was expected, but it also significantly depends on the pressure. Consequently, if the use of a sensor in a sub-cooled area is considered, additional calibration and validation procedures are necessary.

  • This paper was presented at the ECOS'00 Conference in Enschede, July 5-7, 2000 

Year 2001, Volume: 4 Issue: 1, 53 - 60, 01.12.2000

Abstract

There are 0 citations in total.

Details

Primary Language English
Journal Section Regular Original Research Article
Authors

Jean-marc Lebreton This is me

Louis Vuillame This is me

Evelyne Morvan This is me

Olivier Lottin This is me

Publication Date December 1, 2000
Published in Issue Year 2001 Volume: 4 Issue: 1

Cite

APA Lebreton, J.-m., Vuillame, L., Morvan, E., Lottin, O. (2000). Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine. International Journal of Thermodynamics, 4(1), 53-60.
AMA Lebreton Jm, Vuillame L, Morvan E, Lottin O. Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine. International Journal of Thermodynamics. December 2000;4(1):53-60.
Chicago Lebreton, Jean-marc, Louis Vuillame, Evelyne Morvan, and Olivier Lottin. “Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine”. International Journal of Thermodynamics 4, no. 1 (December 2000): 53-60.
EndNote Lebreton J-m, Vuillame L, Morvan E, Lottin O (December 1, 2000) Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine. International Journal of Thermodynamics 4 1 53–60.
IEEE J.-m. Lebreton, L. Vuillame, E. Morvan, and O. Lottin, “Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine”, International Journal of Thermodynamics, vol. 4, no. 1, pp. 53–60, 2000.
ISNAD Lebreton, Jean-marc et al. “Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine”. International Journal of Thermodynamics 4/1 (December 2000), 53-60.
JAMA Lebreton J-m, Vuillame L, Morvan E, Lottin O. Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine. International Journal of Thermodynamics. 2000;4:53–60.
MLA Lebreton, Jean-marc et al. “Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine”. International Journal of Thermodynamics, vol. 4, no. 1, 2000, pp. 53-60.
Vancouver Lebreton J-m, Vuillame L, Morvan E, Lottin O. Oil Concentration Measurement In Saturated Liquid Refrigerant Flowing Inside A Refrigeration Machine. International Journal of Thermodynamics. 2000;4(1):53-60.