<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>j health sci med / jhsm</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Journal of Health Sciences and Medicine</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">2636-8579</issn>
                                                                                            <publisher>
                    <publisher-name>MediHealth Academy Yayıncılık</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.32322/jhsm.1139162</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Health Care Administration</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Sağlık Kurumları Yönetimi</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                                                            <article-title>Comparison of high performance liquid chromatography and turbidimetric inhibition immunoassay methods for measurement of hemoglobin A1c</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-6611-7226</contrib-id>
                                                                <name>
                                    <surname>Cihan</surname>
                                    <given-names>Murat</given-names>
                                </name>
                                                                    <aff>ORDU UNIVERSITY, SCHOOL OF MEDICINE, MEDICINE PR.</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-7060-2216</contrib-id>
                                                                <name>
                                    <surname>Üner</surname>
                                    <given-names>Abdullah</given-names>
                                </name>
                                                                    <aff>ORDU UNIVERSITY, SCHOOL OF MEDICINE, MEDICINE PR.</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-0815-5467</contrib-id>
                                                                <name>
                                    <surname>Kılınçkaya</surname>
                                    <given-names>Muhammed Fevzi</given-names>
                                </name>
                                                                    <aff>Mardin Halk Sağlığı Laboratuvarı</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-7733-0177</contrib-id>
                                                                <name>
                                    <surname>Noyan</surname>
                                    <given-names>Tevfik</given-names>
                                </name>
                                                                    <aff>ORDU UNIVERSITY, SCHOOL OF MEDICINE</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20220925">
                    <day>09</day>
                    <month>25</month>
                    <year>2022</year>
                </pub-date>
                                        <volume>5</volume>
                                        <issue>5</issue>
                                        <fpage>1281</fpage>
                                        <lpage>1285</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20220701">
                        <day>07</day>
                        <month>01</month>
                        <year>2022</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20220717">
                        <day>07</day>
                        <month>17</month>
                        <year>2022</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 2018, Journal of Health Sciences and Medicine</copyright-statement>
                    <copyright-year>2018</copyright-year>
                    <copyright-holder>Journal of Health Sciences and Medicine</copyright-holder>
                </permissions>
            
                                                                                                                        <abstract><p>Aim: Hemoglobin A1c is a valuable parameter for the diagnosis and follow-up of its diabetes mellitus since its biological variation is low, does not require preparation before the test, is not affected by acute stress, and has high preanalytical stability. HbA1c measurement by HPLC has been determined as the reference method by National Glycohemoglobin Standardization Program (NGSP) in USA; after that The International Federation of Clinical Chemistry (IFCC) defined another reference method which could be related with NGSP. In our study, we aim to compare the two NGSP-certified methods of HbA1c, which are high-performance liquid chromatography (HPLC) and turbidimetric inhibition immunoassay (TINIA).Material and Method: HbA1c levels of the patients were measured using two HPLC and one TINIA method in three different hospitals (Lab A, Lab B (Both are HPLC), and Lab C (TINIA), in which Lab A was served as a reference). Because of the lower precision values of LabB, we firstly conducted a method comparison study of 40 volunteers (Group 1). After that, corrective and preventive activities carried out and the precision values in LabB reached the desired range. Following this, another method comparison study consisting of 60 new volunteers (Group 2) was conducted. The statistical flow of this study complied with Clinical Laboratory Standards Institute (CLSI) EP09-A3; Precision studies, Blant-Altman and Passing Bablok regression analysis were performed.Results: The percentage of the mean difference between the two HPLC methods (LabA and LabB) was 3.1%. After corrective and preventive actions had been taken, the mean difference between the two HPLC methods decreased to 2.0%. A decrease in systematic bias was found in our study. Two HPLC methods can be used interchangeably in both Group 1 and Group 2. In Group 1; 95% CI of intercept and slope were found as (-1.41 to -0.30) and (1.03 to 1.22), respectively. In Group 2; 95% CI of intercept and slope were found as (-1.33 to -0.31) and (1.01 to 1.17), respectively. HPLC and TINIA methods could not be used interchangeable without affecting patient results and outcome in both Group 1 and Group 2.Conclusion: Our study concluded that TINIA and HPLC methods could not be used interchangeably without affecting patient results and outcome. Because of the methodology that clinical laboratories are used to, clinicians and clinical biochemists should collaborate on managing diabetes mellitus regarding diagnosis, treatment, and follow-up.</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>Diabetes mellitus</kwd>
                                                    <kwd>  HPLC</kwd>
                                                    <kwd>  immunoturbidimetry</kwd>
                                                    <kwd>  HbA1c</kwd>
                                            </kwd-group>
                            
                                                                                                                                                <funding-group specific-use="FundRef">
                    <award-group>
                                                    <funding-source>
                                <named-content content-type="funder_name">None</named-content>
                            </funding-source>
                                                                            <award-id>None</award-id>
                                            </award-group>
                </funding-group>
                                </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">Bunn HF, Haney DN, Kamin S, Gabbay KH, Gallop PM. The biosynthesis of human hemoglobin A1c. Slow glycosylation of hemoglobin in vivo. J Clin Invest 1976; 57: 1652-9.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">Kaiser P, Reinauer H. Diabetes mellitus: The long way of standardization of HbA1c to the level of highest metrological order. GMS German Med Sci 2011; 9: 1-4.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">EuBIVAS. The EFLM Biological Variation Database: Aarsand AK, Fernandez-Calle P, Webster C, et al.; 2022 [cited 2022 29.06]. Available from: https: //biologicalvariation.eu.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">International Expert C. International Expert Committee report on the role of the A1C assay in the diagnosis of diabetes. Diabetes Care 2009; 32: 1327-34.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">Jeppsson JO, Kobold U, Barr J, et al. Approved IFCC reference method for the measurement of HbA1c in human blood. Clin Chem Lab Med 2002; 40: 78-89.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">Karami A, Baradaran A. Comparative evaluation of three different methods for HbA1c measurement with High-performance liquid chromatography in diabetic patients. Adv Biomed Res 2014; 3: 6-10.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">Penttila I, Penttila K, Holm P, et al. Methods, units and quality requirements for the analysis of haemoglobin A1c in diabetes mellitus. World J Methodol 2016; 6: 133-42.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">Halwachs-Baumann G, Katzensteiner S, Schnedl W, Purstner P, Pieber T, Wilders-Truschnig M. Comparative evaluation of three assay systems for automated determination of hemoglobin A1c. Clin Chem 1997; 43: 511-7.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Consensus C. Consensus statement on the worldwide standardization of the hemoglobin A1C measurement: the American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation. Diabetes Care 2007; 30: 2399-400.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">Hoelzel W, Weykamp C, Jeppsson JO, et al. IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. Clin Chem 2004; 50: 166-74.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">Urrechaga E. Analytical evaluation of the ADAMS () A1c HA8180T analyzer for the measurement of HbA1c. J Clin Lab Anal 2018; 32: 1-6.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">Wu X, Chao Y, Wan Z, et al. A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA1c determination. Biochem Med (Zagreb) 2016; 26: 353-64.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">Syed IA, Khan WA. Glycated haemoglobin--a marker and predictor of cardiovascular disease. J Pak Med Assoc 2011; 61: 690-5.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Genc S, Omer B, Aycan-Ustyol E, Ince N, Bal F, Gurdol F. Evaluation of turbidimetric inhibition immunoassay (TINIA) and HPLC methods for glycated haemoglobin determination. J Clin Lab Anal 2012; 26: 481-5.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">Kın Tekçe B, Tekçe H, Aktaş G, M. T. HbA1c Ölçümünde Architect C 8000 ile MQ-2000PT Sonuçlarının Karşılaştırılması. J Acad Res Med 2015: 52-5.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">Davari Edalat Panah S, Karimian Tousi N, Rahimi L, Sabouri G, Mirsalehi A, Zahedi Avval F. Comparison of Two Methods for Measurement of HbA1c in Two University Hospitals of Mashhad. Journal of Patient Safety &amp; Quality Improvement 2015; 3: 262-5.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">CLSI. EP09-A3: Measurement Procedure Comparison and Bias Estimation Using Patient Samples. USA: CLSI; 2018. p. 15-9.</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">Pum J. A practical guide to validation and verification of analytical methods in the clinical laboratory. Adv Clin Chem 2019; 90: 215-81.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">Ozcelik F, Yiginer O, Serdar M, et al. Comparison of three methods for measurement of HbA1c. Turk J Biochem 2010; 35: 344-9.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">Hamwi A, Schweiger CR, Veitl M, Schmid R. Quantitative measurement of HbA1c by an immunoturbidimetric assay compared to a standard HPLC method. Am J Clin Pathol 1995; 104: 89-95.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">Groche D, Hoeno W, Hoss G, Vogt B, Herrmann Z, Witzigmann A. Standardization of two immunological HbA1c routine assays according to the new IFCC reference method. Clin Lab 2003; 49: 657-61.</mixed-citation>
                    </ref>
                                    <ref id="ref22">
                        <label>22</label>
                        <mixed-citation publication-type="journal">Sağlık Bakanlığı. Sağlık Uygulama Tebliği 2022 [cited 2022 15.07]. Available from: https://www.mevzuat.gov.tr/File/Pdf?mevzuatNo=17229&amp;mevzuatTur=Teblig&amp;mevzuatTertip=5.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>
