<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>j health sci med / jhsm</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Journal of Health Sciences and Medicine</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">2636-8579</issn>
                                                                                            <publisher>
                    <publisher-name>MediHealth Academy Yayıncılık</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.32322/jhsm.1341282</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Medical Biochemistry and Metabolomics (Other)</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Tıbbi Biyokimya ve Metabolomik (Diğer)</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                                                            <article-title>The transition from gel separatory serum tubes to lithium heparin gel tubes in the clinical laboratory</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-4614-5235</contrib-id>
                                                                <name>
                                    <surname>Zengi</surname>
                                    <given-names>Oğuzhan</given-names>
                                </name>
                                                                    <aff>UNIVERSITY OF HEALTH SCIENCES, HEALTH RESEARCH CENTER</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20230928">
                    <day>09</day>
                    <month>28</month>
                    <year>2023</year>
                </pub-date>
                                        <volume>6</volume>
                                        <issue>5</issue>
                                        <fpage>998</fpage>
                                        <lpage>1009</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20230811">
                        <day>08</day>
                        <month>11</month>
                        <year>2023</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20230903">
                        <day>09</day>
                        <month>03</month>
                        <year>2023</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 2018, Journal of Health Sciences and Medicine</copyright-statement>
                    <copyright-year>2018</copyright-year>
                    <copyright-holder>Journal of Health Sciences and Medicine</copyright-holder>
                </permissions>
            
                                                                                                                        <abstract><p>Aims: To assess the viability of replacing serum samples with plasma samples in various clinical chemistry and immunoassay tests and to examine the implications of turnaround time (TAT) and sample quality during the transition process.Methods: We compared the results of 27 paired clinical chemistry and 13 immunoassay tests from samples obtained using gel separator serum and gel separator lithium heparinized plasma (LIH) tubes. We used regression analysis, bias values, and Bland-Altman plots to compare the performance of serum and LIH tubes in various clinical chemistry and immunoassay tests. We collected and evaluated sample aspiration errors, hemolysis index values, and TAT data from the laboratory information system before and after switching to plasma in our study.Results: Most tests showed no significant difference between the serum and LIH. However, for some analytes, total error (TE) values exceeded the total allowable error (TEa) limits derived from the biological variation database. Notably, insulin TE value did not exceed TEa, but it consumed near all its error budget. Consequently, we determined the alternative allowable error limits for some tests and found that plasma tubes could be used instead of serum tubes for most tests, except for lactate dehydrogenase (LDH). Plasma tubes improved the sample quality, reduced the incidence of aspiration errors, and decreased TAT in the emergency laboratory. We observed significant reductions in TAT after switching to plasma tubes.Conclusion: Our study showed that LIH tubes can replace serum tubes in most clinical chemistry and immunoassay tests. Using LIH tubes in clinical laboratories can improve healthcare quality and reduce the workload of the laboratory staff.</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>Plasma</kwd>
                                                    <kwd>  serum</kwd>
                                                    <kwd>  total error</kwd>
                                                    <kwd>  turnaround time</kwd>
                                                    <kwd>  sample quality</kwd>
                                            </kwd-group>
                            
                                                                                                                                                    </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">World Health Organization. Diagnostic Imaging and Laboratory Technology. (2002). Use of anticoagulants in diagnostic laboratory investigations. World Health Organization. Accessed May 3, 2023.https://apps.who.int/iris/handle/10665/65957</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">Valenstein P. Laboratory turnaround time. Am J Clin Pathol. 1996;105(6):676-688. doi:10.1093/ajcp/105.6.676</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">Güvenç Demirağcı Y. Laboratuvar sonuç verme sürelerinin değerlendirilmesi. ET J. 2018;5(3):54-58.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">Arslan FD, Karakoyun I, Basok BI, et al. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH plasma tube. Biochem Medica. 2017;27(3):030706. doi:10.11613/BM.2017.030706</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">Lippi G, Cornes MP, Grankvist K, Nybo M, Simundic AM. EFLM WG-Preanalytical phase opinion paper: local validation of blood collection tubes in clinical laboratories. Clin Chem Lab Med CCLM. 2016;54(5). doi:10.1515/cclm-2015-1274</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">CLSI. Validation and Verification of Tubes for Venous and Capillary Blood Specimen Collection; Approved Guideline. CLSI document GP34-A Wayne, PA: Clinical and Laboratory Standards Institute; 2010.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">Quality Requirements-Westgard. Accessed February 5, 2023. https://www.westgard.com/quality-requirements.htm</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">Aarsand AK, Fernandez-Calle P, Webster C, et al. The EFLM Biological variation database. Accessed Jue 25, 2023. Available at: https://biologicalvariation.eu/</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Sun H, Wang W, Zhao H, et al. Internal quality control status for BNP and NT-proBNP in China from 2014 to 2017. J Clin Lab Anal. 2019;33(1):e22643. doi:10.1002/jcla.22643</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">Oosterhuis WP, Coskun A, Sandberg S, Theodorsson E. Performance specifications for sodium should not be based on biological variation. Clin Chim Acta. 2023;540:117221. doi:10.1016/j.cca.2023.117221</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">Hétu PO, Hobeila S, Larivière F, Bélanger MC. Improved sample quality and decreased turnaround time when using plasma blood collection tubes with a mechanical separator in a large university hospital. J Appl Lab Med. 2021;6(2):409-420. doi:10.1093/jalm/jfaa111</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">Lima-Oliveira G, Monneret D, Guerber F, Guidi GC. Sample management for clinical biochemistry assays: Are serum and plasma interchangeable specimens? Crit Rev Clin Lab Sci. 2018;55(7):480-500. doi:10.1080/10408363.2018.1499708</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">Wang YS, Feng CF, Er TK, et al. Comparison of cardiac troponin I levels in serum and sodium-citrate plasma using the ACCESS 2 immunoassay. Ann Clin Lab Sci. 2005;35(4):453-454.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Ercan Ş. Comparison of test results obtained from lithium heparin gel tubes and serum gel tubes. Turk J Biochem. 2020;45(5):575-586. doi:10.1515/tjb-2019-0117</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">Ferrari D, Strollo M, Vidali M, Motta A, Pontillo M, Locatelli M. Biochemical, immunochemical and serology analytes validation of the lithium heparin BD Barricor blood collection tube on a highly automated Roche COBAS8000 instrument. Acta Bio Medica Atenei Parm. 2020;91(1):47-55. doi:10.23750/abm.v91i1.9195</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">Arslan FD, Karakoyun I, Basok BI, et al. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube. Biochem Medica. 2017;27(3):030706. doi:10.11613/BM.2017.030706</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">Bockoven C, Granato M, Benirschke R, Lee H. Differing plasma and serum lactate dehydrogenase concentrations. Am J Clin Pathol. 2018;149(suppl_1):S13-S13. doi:10.1093/ajcp/aqx116.029</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">Consolidated Comparison of Chemistry Performance Specifications-Westgard. Accessed April 4, 2023. https://www.westgard.com/consolidated-goals-chemistry.htm</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">Kalra A. Decoding the bland-altman plot: basic review. J Pract Cardiovasc Sci. 2017;3(1):36. doi:10.4103/jpcs.jpcs_11_17</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">Orhan B, Mercan H, Deniz L, Erdogan Z, Bercik Inal B. Comparison of Barricor tube and serum separator tube in outpatients. Turk J Biochem. 2022;47(6):719-726. doi:10.1515/tjb-2022-0168</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">Cadamuro J, Mrazek C, Leichtle AB, et al. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes. Biochem Medica. 2018;28(1):010704. doi:10.11613/BM.2018.010704</mixed-citation>
                    </ref>
                                    <ref id="ref22">
                        <label>22</label>
                        <mixed-citation publication-type="journal">Shin S, Oh J, Park HD. Comparison of three blood collection tubes for 35 biochemical analytes: the Becton Dickinson Barricor tube, serum separating tube, and plasma separating tube. Ann Lab Med. 2021;41(1):114-119. doi:10.3343/alm.2021.41.1.114</mixed-citation>
                    </ref>
                                    <ref id="ref23">
                        <label>23</label>
                        <mixed-citation publication-type="journal">Kösem A, Topçuoğlu C, Sezer S, et al. Comparison of some biochemical tests in different blood collection tubes in hemodialysis patients. Turk J Biochem. 2020;45(1):26-36. doi:10.1515/tjb-2018-0341</mixed-citation>
                    </ref>
                                    <ref id="ref24">
                        <label>24</label>
                        <mixed-citation publication-type="journal">Gawria G, Tillmar L, Landberg E. A comparison of stability of chemical analytes in plasma from the BD Vacutainer ® BarricorTM tube with mechanical separator versus tubes containing gel separator. J Clin Lab Anal. 2020;34(2). doi:10.1002/jcla.23060</mixed-citation>
                    </ref>
                                    <ref id="ref25">
                        <label>25</label>
                        <mixed-citation publication-type="journal">Dimeski G, Johnston J. Is the BD Barricor tube the new standard for lithium heparin plasma. Developments Clin Med Pathol. 2018;1(3):1-5 doi: 10.31031/DCMP.2018.01.000514</mixed-citation>
                    </ref>
                                    <ref id="ref26">
                        <label>26</label>
                        <mixed-citation publication-type="journal">Ryan J, Stuart L, Southby S, et al. Comparison of BD Vacutainer® rapid serum tube and plasma for haemolysis markers in the emergency department. Ann Clin Biochem Int J Lab Med. 2015;52(2):293-296. doi:10.1177/0004563214533317</mixed-citation>
                    </ref>
                                    <ref id="ref27">
                        <label>27</label>
                        <mixed-citation publication-type="journal">Miles RR. Comparison of serum and heparinized plasma samples for measurement of chemistry analytes. Clin Chem. 2004;50(9):1703-1704. doi:10.1373/clinchem.2004.036483</mixed-citation>
                    </ref>
                                    <ref id="ref28">
                        <label>28</label>
                        <mixed-citation publication-type="journal">Ramakers C, Meyer B, Yang W, et al. Switching from serum to plasma: Implementation of BD Vacutainer® BarricorTM plasma blood collection tubes improves sample quality and laboratory turnaround time. Pract Lab Med. 2020;18:e00149. doi:10.1016/j.plabm.2019.e00149</mixed-citation>
                    </ref>
                                    <ref id="ref29">
                        <label>29</label>
                        <mixed-citation publication-type="journal">Badiou S, Vuillot O, Bargnoux AS, et al. Improved quality of samples and laboratory turnaround time using 3.5 mL low vacuum BD Vacutainer® Barricor tubes in the emergency department. Pract Lab Med. 2019;16:e00128. doi:10.1016/j.plabm.2019.e00128</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>