Nowadays, determination of minimum water flow from dams that are build on rivers, has a vital importance in order to utilize water resources effectively and efficiently. In this study, minimum water flow for Boğazköy Dam and HEPP is calculated based on two different hydrologic methods, namely flow duration curve and Tennant (1976) methods and they are compared with each other. As a result of current study, based on Tennant method, for raid periods minimum 1,34 m3/sec and for wet periods minimum 1,69 m3/sec water flow is calculated. Based on flow duration method Q70 and Q95 are calculated respectively 6,59 m3/sec and 2,47 m3/sec. Between selected methods, it is more convenient to use the Q70 for the environmental flow
Su kaynaklarından etkin ve verimli bir şekilde faydalanmak için
akarsular üzerine inşa edilen su yapılarından akış aşağıya bırakılması gereken
asgari su miktarının hesaplanması günümüzde büyük önem taşımaktadır.
Çalışmada, Boğazköy Baraj ve HES’inden akış aşağıya bırakılması gereken
asgari su miktarı hidrolojik verilere dayalı Tennant (1976) ve akım süreklilik
yöntemi ile karşılaştırmalı olarak ele alınmıştır. Seçili yöntemler ile akarsu
yatağında bulunması gereken asgari su miktarı hesaplanmıştır. Tennant (1976)
yöntemine göre asgari su miktarı kurak dönemler için 1,34 m3
/sn ve yağışlı
dönemler için 1,69 m3
/sn olarak belirlenmiştir. Akım süreklilik yöntemine göre
Q70 6,59 m3
/sn ve Q95 2,47 m3
/sn olarak hesaplanmıştır. Seçili yöntemlerden,
çevresel akış için Q70 değerinin kullanılması daha uygundur.