<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>mersin univ saglık bilim derg</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Mersin Üniversitesi Sağlık Bilimleri Dergisi</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">1308-0830</issn>
                                                                                            <publisher>
                    <publisher-name>Mersin University</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.26559/mersinsbd.605225</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Health Care Administration</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Sağlık Kurumları Yönetimi</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                        <article-title>Konik ve silindirik pedikül vidalarının sıyırma dirençleri ve direngenliklerinin karşılaştırmalı biyomekanik analizi</article-title>
                                                                                                                                                                                                <trans-title-group xml:lang="en">
                                    <trans-title>A comparative biomechanical analysis of pull-out resistance and stiffness of conical and cylindrical pedicle screws</trans-title>
                                </trans-title-group>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0003-4521-4312</contrib-id>
                                                                <name>
                                    <surname>Polat</surname>
                                    <given-names>Ömer</given-names>
                                </name>
                                                                    <aff>DÜZCE ÜNİVERSİTESİ, TIP FAKÜLTESİ, TIP PR.</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0003-2157-7477</contrib-id>
                                                                <name>
                                    <surname>Gezici</surname>
                                    <given-names>Ali Rıza</given-names>
                                </name>
                                                                    <aff>BOLU ABANT İZZET BAYSAL ÜNİVERSİTESİ, TIP FAKÜLTESİ</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-3845-2665</contrib-id>
                                                                <name>
                                    <surname>Uçkun</surname>
                                    <given-names>Özhan Merzuk</given-names>
                                </name>
                                                                    <aff>ANKARA NUMUNE SAĞLIK UYGULAMA VE ARAŞTIRMA MERKEZİ</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0002-1503-1016</contrib-id>
                                                                <name>
                                    <surname>Nacar</surname>
                                    <given-names>Osman Arıkan</given-names>
                                </name>
                                                                    <aff>YÜKSEK İHTİSAS ÜNİVERSİTESİ</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20191231">
                    <day>12</day>
                    <month>31</month>
                    <year>2019</year>
                </pub-date>
                                        <volume>12</volume>
                                        <issue>3</issue>
                                        <fpage>367</fpage>
                                        <lpage>377</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20190813">
                        <day>08</day>
                        <month>13</month>
                        <year>2019</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20190918">
                        <day>09</day>
                        <month>18</month>
                        <year>2019</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 2008, Mersin Üniversitesi Sağlık Bilimleri Dergisi</copyright-statement>
                    <copyright-year>2008</copyright-year>
                    <copyright-holder>Mersin Üniversitesi Sağlık Bilimleri Dergisi</copyright-holder>
                </permissions>
            
                                                                                                <abstract><p>Amaç: Transpediküler enstrümantasyonda konikve silindirik pedikül vidaları sık kullanılmaktadır. Vidaların mekanikperformansı kemik-vida yüzeyinin biyomekanik özellikleri ve vidanın fizikselyapısı ile ilişkilidir. Bu çalışmada, konik ve silindirik pedikül vidalarınınbiyomekanik açıdan farklarının olup olmadığının araştırılması amaçlandı. Yöntem: İskelet maturasyonunutamamlamış, 400-600 kg ağırlığında 24–32 haftalık danalardan elde edilmiş taze lombervertebralar kullanıldı. Toplam 24vertebranın her iki pedikülüne (48 pedikül) vida yerleştirilerek biyomekaniktestler uygulandı. Vidaların maksimum giriş tork değerleri analog tork metre kullanılarakkaydedildi. Rijidtespitin sağlanması için polimetilmetakrilat içeren metal kutuların içerisinegömülü vertebradaki pedikül vidaları mekanik test makinasına bağlanarak sıyırmadirenci ölçüldü. Bulgular: Konikvidaların sıyırma dirençlerinin ve direngenliklerinin ilk atım ve tekrarlayanatımlarda silindirik vidalara göre yüksek olduğu, ancak aradaki farkınistatistiksel olarak anlamlı olmadığı tespit edildi (p&amp;gt;0.05). Maksimum giriştork değeri ise konik vidalarda silindirik vidalara göre istatistiksel olarakanlamlı düzeyde yüksek idi (p=0.04). Vidaların 180º ve 360°geri çekimli sıyırmadirenci ve direngenlik verileri arasında istatistiksel olarak anlamlı farkolmadığı tespit edildi (p&amp;gt;0.05). Sonuç:Konik vidaların silindirik vidalara göre daha dirençli tutunma verilerinesahip olmalarının yanı sıra, aynı delikten yapılan çoklu vida atımlarında ya dageri çekilme işlemi sonucunda vidalar arasında sıyrılma verileri açısındanbelirgin bir fark izlenmemiş olması, konik vidaların gelecekte daha sıkkullanılacaklarını düşündürmektedir.</p></abstract>
                                                                                                                                    <trans-abstract xml:lang="en">
                            <p>Aim:Conical and cylindrical pedicle screws are frequently usedin transpedicular instrumentation. The mechanical performance of screws isassociated with the biomechanical properties of the bone–screw surface and thephysical structure of the screw. The purpose of this study was to investigatewhether conical and cylindrical pedicle screws differ in their biomechanicalproperties. Methods: Fresh lumbarvertebrae were obtained from 24–32-week-old calves that completed skeletalmaturation and weighed 400–600 kg. Screws were placed on both pedicles (48pedicles) of total 24 vertebrae, and biomechanical tests were performed. Themaximum input torque values of the screws were recorded using an analog torquemeter. Pull-out resistance was measured by attaching pedicle screws in thevertebra. The vertebral pedicle screws were embedded into metal boxescontaining polymethyl-methacrylate to provide rigid fixation to a mechanicaltester. Results: Pull-out resistanceand stiffness were higher in conical screws than in cylindrical screws in thefirst and repetitive insertions; however, the difference was not statisticallysignificant (p&amp;gt;0.05). The maximum input torque was significantly higher(p=0.04) in conical screws than in cylindrical screws. No significantdifference (p&amp;gt;0.05) was observed between pull-out resistance and stiffnessvalues of the screws with 180° and 360° back-outs. Conclusion: Conical screws had more resistant fixation data thancylindrical screws, and there was no significant difference between the screwsin terms of pull-out resistance data due to multiple screw insertions performedfrom the same hole or due to the back-out procedure; this indicates thatconical screws are likely be used more frequently in the future.</p></trans-abstract>
                                                            
            
                                                            <kwd-group>
                                                    <kwd>Transpediküler fiksasyon</kwd>
                                                    <kwd>  Konik vida</kwd>
                                                    <kwd>  Silindirik vida</kwd>
                                                    <kwd>  Biyomekanin analiz</kwd>
                                            </kwd-group>
                                                        
                                                                            <kwd-group xml:lang="en">
                                                    <kwd>Transpedicular fixation</kwd>
                                                    <kwd>  conical screw</kwd>
                                                    <kwd>  cylindrical screw</kwd>
                                                    <kwd>  biomechanical analysis</kwd>
                                            </kwd-group>
                                                                                                            </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">1-	Abshire BB, McLain RF, Valdevit A, Kambic HE. Charecteristic of pullout failure in conical and cylindrical screws after full insertion and back-out. Spine J 2001;1(6):408-414.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">2-	Skinner R, Maybee J, Transfeldt E, Venter R, Chalmers W. Experimental pullout testing and comparison of variable in transpedicular screw fixation. Spine 1990;15:195-201.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">3-	Esses SI, Sachs BL, Dryzin V. Complications associated with the technice of pedicle screw fixation. A selected survey of ABS Members. Spine 1993;18(15):2231-2238.  4-	Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on succesfull screw placement. Spine 1988;13(19):1012-1018.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">5-	Kwok AWL, Finklestein JA, Woodside T, Hearn TC, Hu RW. İnsertional torque and pull-out strengths of conical and clindyrical pedicle screw in cadaveric bone. Spine 1996;21(21):2429-2434.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">6-	Ransom N, La Rocca SH, Thalgott J. The case for pedicle fixation of the lomber spine. Spine 1994;19(23):2702-2706.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">7-	Schwab FJ, Nazarian DG, Mahmut F, Michelsen CB. Effects of spinal esrumantation on fusion of the lumbsacral spine. Spine 1995;20(18):2023-2028.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">8-	Dicman CA, Fesler RG, Macmillan M, Haid RW. Transpedicular screw-rod fixation of the lumber spine:operative technice and outcome in 104 cases. J Neurosurgery 1992;77:860-870.9-	McLain R, Sparling E, Benson D. Early failture of the short segment pedicle instrumantation for thoracolumbar fractures: a preliminary report. J Bone Joint Surg 1993;75A:162-167.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">10-	Pfeifer M, Hoffman H, Goel VK, Weinstein JN, Griss P. In vitro testing of a new transpedicular stablization technique. Eur Spine J 1997;6(4):249-255. 11-	Davne SH, Myers SL. Complications of lumbar spinl fusion with transpedicular instrumantaton. Spine 1992;17(supp):S184-189.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">12-	McKinley TO, McLain RF Yerby SA, Sarıgül- Klijn N, Smith TS.The effect of pedicle morphometry on pedicle screw loading in unstable burst fractures: a synthetic model. Spine 1997;22(3):246-252.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">13-	Yerby SA, Ehteshami JR, McLain RF. Loading of pedicle screws within the vertebra. J Biomechanics 1997;30(9):951-954.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">14-	Yamagata M, Kitahara H, Minami S, etc and all. Mechanical stability of pedicle screw systems fort the lumbar spine. Spine 1992;17(supp):S51-54.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">15-	Daftari DK, Horton WC, HuttoN WC. Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws. J Spinal Disord 1994;7(2):139-145.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">16-	Pfeifer M, Gilbertson LG, Goel VK, et al. Effect of specimen fixation method on pull-out tests of pedicle screws. Spine 1996;21:1037-1044.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">17-	Kılınçer C, İnceoğlu S, Çaylı S, Zileli M, Ferara L. Biomehanical analysis of a Turkis-Made posterior spinal instrumantation system. Turkish Neurosurgery 2005;15(2):58-63.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">18-	 İnceoğlu S, Ferrara L, Mclain RF. Pedicle screw fixation strenght: pullout versus insertional torque. Spine J 2004;4:513-518.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">19-	McLain RF, Fry MF, Moseley TA, Sharkey NA. Lumba pedicle screw salvage:pull-out testing of three different pedicle screw designs. J Spinal Disor 1995;8(1):62-68.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">20-	Ashman RB, Galpin RD, Corin JD, Johnston CE. Biomechanical analysis of pedicle screw instrumantation systems in a corpectomy model. Spine 1989;14:1398-1405.</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">21-	Zindrick MR, Wiltse LL, Widel EH, Thomas JC, Holland WR, Field BT, Spencer CW. A biomechanical study of intrapedincular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 1986;203:99-112.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">22-	Myers B, Belmont P, Richardson w, Yu J, Harper K, Nightingale R. The role of imaging and in situ biomechanical testing in assessing  pedicle screw pullout strenght. Spine 1996;21:1962-1968.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">23-	Soshi S, Shiba R, Kondo H, Murato K. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991;16(11):1335-1341.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">24-	Hirano T, Hasegava K, Takahashi HE, Uchiyama S, Hara T, Washio T, Sugiura T, Yokaichiya M, Ikeda M. Structurel characteristics of the pedicle and its role in screw stabilty. Spine 1997;22:2504-2509.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>