BibTex RIS Cite

PERFORMANCE INVESTIGATION OF SLINKY HEAT EXCHANGER FOR SOLAR ASSISTED GROUND SOURCE HEAT PUMP

Year 2014, Volume: 9 Issue: 1, 1 - 12, 01.02.2014

Abstract

In the following study, 12 m2 test chamber was heated by solar and ground source heat pump under the physical conditions of Elazığ. In order to place slinky heat exchanger pipes, a hole was dug with 1 meter width, 2 meters depth and 15 meters length. Slinky pipes were put horizontally in the hole and water-antifreeze mixture was circulated with the circulating pump in the slinky heat exchanger. The heat taken from the ground was transferred into the environment to be heated through the heat pump. Also the system was operated as solar assisted with the 6 flat-plate solar collectors being placed. Thus, the performance of the operating system could be investigated.

References

  • Utlu, Z., (1999). The design of heat pump assisted by a solar system in the conditions of İzmir. MSc. Thesis. İzmir: Ege University Institute of Science.
  • Akpınar, A., Kömürcü, M.İ., and Filiz, M.H., (2008). Türkiye’nin enerji kaynakları ve çevre, sürdürülebilir kalkınma ve temiz enerji kaynakları, VII. National Clean Energy Symposiums, UTES’ 2008, İstanbul, 17-19 December, pp: 12-24.
  • Özgener, L., (2005). Exergoeconomic analysis of geothermal district heating systems. PhD. Thesis. İzmir: Ege University Institute of Science.
  • Tunç, M., Uysal, M., and Özmen, A., (1988). Exergy analysis of solar-assisted heat pump systems. Applied Energy, 29, pp: 1-16.
  • Esen, H., (2007). Investigation of seasonal behaviour of a

SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI

Year 2014, Volume: 9 Issue: 1, 1 - 12, 01.02.2014

Abstract

Yapılan çalışmada Elazığ iklim şartlarında 12 m2 alanındaki deney odası güneş ve toprak kaynaklı ısı pompası ile ısıtılmıştır. 1m eninde, 2m derinliğinde ve 15 m uzunluğunda çukur kazılarak slinky toprak ısı değiştirgeci borularını bu çukur içine yatay olarak yerleştirilmiştir. Bir sirkülasyon pompası yardımı ile su-antifriz karışımı yatay slinky toprak ısı değiştirgeci içinde dolaştırılarak topraktan çekilen ısı, ısı pompası vasıtasıyla ısıtılacak ortama verilmiştir. Ayrıca sistem, yerleştirilen 6 adet düzlemsel güneş kollektörü ile güneş destekli olarak çalıştırılarak bu sistemin performansı araştırılmıştır.

References

  • Utlu, Z., (1999). The design of heat pump assisted by a solar system in the conditions of İzmir. MSc. Thesis. İzmir: Ege University Institute of Science.
  • Akpınar, A., Kömürcü, M.İ., and Filiz, M.H., (2008). Türkiye’nin enerji kaynakları ve çevre, sürdürülebilir kalkınma ve temiz enerji kaynakları, VII. National Clean Energy Symposiums, UTES’ 2008, İstanbul, 17-19 December, pp: 12-24.
  • Özgener, L., (2005). Exergoeconomic analysis of geothermal district heating systems. PhD. Thesis. İzmir: Ege University Institute of Science.
  • Tunç, M., Uysal, M., and Özmen, A., (1988). Exergy analysis of solar-assisted heat pump systems. Applied Energy, 29, pp: 1-16.
  • Esen, H., (2007). Investigation of seasonal behaviour of a
There are 5 citations in total.

Details

Primary Language Turkish
Journal Section Electrical Machines
Authors

Onur Özsolak This is me

Mehmet Esen This is me

Publication Date February 1, 2014
Published in Issue Year 2014 Volume: 9 Issue: 1

Cite

APA Özsolak, O., & Esen, M. (2014). SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI. Technological Applied Sciences, 9(1), 1-12. https://doi.org/10.12739/NWSA.2014.9.1.2A0084
AMA Özsolak O, Esen M. SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI. Technological Applied Sciences. February 2014;9(1):1-12. doi:10.12739/NWSA.2014.9.1.2A0084
Chicago Özsolak, Onur, and Mehmet Esen. “SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI”. Technological Applied Sciences 9, no. 1 (February 2014): 1-12. https://doi.org/10.12739/NWSA.2014.9.1.2A0084.
EndNote Özsolak O, Esen M (February 1, 2014) SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI. Technological Applied Sciences 9 1 1–12.
IEEE O. Özsolak and M. Esen, “SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI”, Technological Applied Sciences, vol. 9, no. 1, pp. 1–12, 2014, doi: 10.12739/NWSA.2014.9.1.2A0084.
ISNAD Özsolak, Onur - Esen, Mehmet. “SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI”. Technological Applied Sciences 9/1 (February 2014), 1-12. https://doi.org/10.12739/NWSA.2014.9.1.2A0084.
JAMA Özsolak O, Esen M. SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI. Technological Applied Sciences. 2014;9:1–12.
MLA Özsolak, Onur and Mehmet Esen. “SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI”. Technological Applied Sciences, vol. 9, no. 1, 2014, pp. 1-12, doi:10.12739/NWSA.2014.9.1.2A0084.
Vancouver Özsolak O, Esen M. SLİNKY ISI DEĞİŞTİRGEÇLİ GÜNEŞ DESTEKLİ TOPRAK KAYNAKLI ISI POMPASININ PERFORMANS ARAŞTIRMASI. Technological Applied Sciences. 2014;9(1):1-12.