Research Article
BibTex RIS Cite

Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows

Year 1997, Volume: 10 Issue: 1, 46 - 58, 30.06.1997

Abstract

This study disscusses design and calibration
of a rotameter set for measurement of gas flows. In Ihis study, various gases
(such as hydrogen, carbon dioxide, methane, nitrogen and argon) are used for
calibralion of the rotameter set. Each rotameter was calibraled with one or two
gases and resıılting gas flowrates through the rotameters (R1, R2 and R3)
compared with each other according to their molecular weight.

References

  • [1] E.M. Schoenbom, Jr. and A.P. Colbum, The Flow Mechanism and Performance of The Rotameter, American Institute ofChemical Engineers, Ohio Meeting, pp. 359-389, 1939.
  • [2] M.C. Coleman, Variable Arca Flow Meters, Trans. lnsl. Chem. Engrs.,\. 3a,, pp. 339-350, 1956.
  • [3] JJ. Martin, Calibration of Rotameters, Chemica! Engineering Progress, pp.338-342, 1949.
  • [4] H.H. Dijstelbergen, Rotameter Dynamics, Chemical Engmeering Selence, pp.853-865, 1964.
  • [5] G.S. Harrison and W.D. Armstrong, The frequency response of rotameters, Chemical Engineering Selence, pp. 253-259, 1960.
  • [6] J.M. Coulson and J.F. Richardson, Chemical Engineering, Vol. I, 4 Ed., Pergamon Press, Oxford, 1990.
  • [7] C.O. Bennett and J.E. Myers, Momentum, Heat and Mass Transfer, 3 .Ed., Mc0raw- Hill Book Comp., London, 1982.
  • [8] N. De Nevers, Fluid Mechanics far Chemical Engineers, 2 . Ed., McGravv-Hill Inc., Paris, 1991.
  • [9] M. Levent, A Microreactor far The Determination of Intrinsic Kinetics on Catalysts, PhD Thesis, University ofWales, Swansea, United Kingdom, 283 pages, 1994.

Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows

Year 1997, Volume: 10 Issue: 1, 46 - 58, 30.06.1997

Abstract

This study disscusses design and calibration of a rotameter set for measurement of gas flows. In Ihis study, various gases (such as hydrogen, carbon dioxide, methane, nitrogen and argon) are used for calibralion of the rotameter set. Each rotameter was calibraled with one or two gases and resıılting gas flowrates through the rotameters (R1, R2 and R3) compared with each other according to their molecular weight.

References

  • [1] E.M. Schoenbom, Jr. and A.P. Colbum, The Flow Mechanism and Performance of The Rotameter, American Institute ofChemical Engineers, Ohio Meeting, pp. 359-389, 1939.
  • [2] M.C. Coleman, Variable Arca Flow Meters, Trans. lnsl. Chem. Engrs.,\. 3a,, pp. 339-350, 1956.
  • [3] JJ. Martin, Calibration of Rotameters, Chemica! Engineering Progress, pp.338-342, 1949.
  • [4] H.H. Dijstelbergen, Rotameter Dynamics, Chemical Engmeering Selence, pp.853-865, 1964.
  • [5] G.S. Harrison and W.D. Armstrong, The frequency response of rotameters, Chemical Engineering Selence, pp. 253-259, 1960.
  • [6] J.M. Coulson and J.F. Richardson, Chemical Engineering, Vol. I, 4 Ed., Pergamon Press, Oxford, 1990.
  • [7] C.O. Bennett and J.E. Myers, Momentum, Heat and Mass Transfer, 3 .Ed., Mc0raw- Hill Book Comp., London, 1982.
  • [8] N. De Nevers, Fluid Mechanics far Chemical Engineers, 2 . Ed., McGravv-Hill Inc., Paris, 1991.
  • [9] M. Levent, A Microreactor far The Determination of Intrinsic Kinetics on Catalysts, PhD Thesis, University ofWales, Swansea, United Kingdom, 283 pages, 1994.
There are 9 citations in total.

Details

Subjects Chemical Engineering
Journal Section Research Articles
Authors

Menderes Levent

Publication Date June 30, 1997
Acceptance Date January 1, 1997
Published in Issue Year 1997 Volume: 10 Issue: 1

Cite

APA Levent, M. (1997). Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows. Eskişehir Osmangazi Üniversitesi Mühendislik Ve Mimarlık Fakültesi Dergisi, 10(1), 46-58.
AMA Levent M. Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows. ESOGÜ Müh Mim Fak Derg. June 1997;10(1):46-58.
Chicago Levent, Menderes. “Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows”. Eskişehir Osmangazi Üniversitesi Mühendislik Ve Mimarlık Fakültesi Dergisi 10, no. 1 (June 1997): 46-58.
EndNote Levent M (June 1, 1997) Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi 10 1 46–58.
IEEE M. Levent, “Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows”, ESOGÜ Müh Mim Fak Derg, vol. 10, no. 1, pp. 46–58, 1997.
ISNAD Levent, Menderes. “Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows”. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi 10/1 (June 1997), 46-58.
JAMA Levent M. Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows. ESOGÜ Müh Mim Fak Derg. 1997;10:46–58.
MLA Levent, Menderes. “Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows”. Eskişehir Osmangazi Üniversitesi Mühendislik Ve Mimarlık Fakültesi Dergisi, vol. 10, no. 1, 1997, pp. 46-58.
Vancouver Levent M. Design And Calibration Of A Rotameter Set For Measurement Of Gas Flows. ESOGÜ Müh Mim Fak Derg. 1997;10(1):46-58.

20873  13565  13566 15461  13568    14913