<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                    <journal-id></journal-id>
            <journal-title-group>
                                                                                    <journal-title>Politeknik Dergisi</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">2147-9429</issn>
                                                                                            <publisher>
                    <publisher-name>Gazi University</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.2339/politeknik.825028</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Engineering</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Mühendislik</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                        <article-title>Doğru Akım Uygulanan Betonlarda Donatı Çapının Hızlandırılmış Korozyon Başlangıcına Etkisinin Araştırılması</article-title>
                                                                                                                                                                                                <trans-title-group xml:lang="en">
                                    <trans-title>Investigation of the Impacts of Reinforcement Steel’s Diameters on Accelerated Corrosion Begining for the Concretes to which Direct Current Applied</trans-title>
                                </trans-title-group>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-9294-1120</contrib-id>
                                                                <name>
                                    <surname>Hocaoğlu</surname>
                                    <given-names>İsmail</given-names>
                                </name>
                                                                    <aff>AFYON KOCATEPE UNIVERSITY, BOLVADİN VOCATIONAL SCHOOL</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20220301">
                    <day>03</day>
                    <month>01</month>
                    <year>2022</year>
                </pub-date>
                                        <volume>25</volume>
                                        <issue>1</issue>
                                        <fpage>381</fpage>
                                        <lpage>388</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20201112">
                        <day>11</day>
                        <month>12</month>
                        <year>2020</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20210715">
                        <day>07</day>
                        <month>15</month>
                        <year>2021</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1998, Journal of Polytechnic</copyright-statement>
                    <copyright-year>1998</copyright-year>
                    <copyright-holder>Journal of Polytechnic</copyright-holder>
                </permissions>
            
                                                                                                <abstract><p>Bu çalışmada 300 dozajlı, 15cm küp boyutundaki betonlara hızlandırılmış korozyon deneyi uygulanmıştır. Betonların orta noktalarına donatı çapları sırası ile ø12, ø14 ve ø16 olan donatılar yerleştirilmiştir. Üretilen betonlar kalıplardan çıkartıldıktan sonra 28 gün süre ile kür edilmiştir. Betonlarda hızlandırılmış korozyon testi yapabilmek için DC güç kaynağı vasıtası ile 30 V gerilim uygulanmıştır. Betonlara uygulanan akım ampermetre ile kaydedilmiş ve çeşitli karşılaştırmalar yapılmıştır. Beton içerisindeki donatı çapının artması ile betondaki korozyon şiddetinin azaldığı sonucuna ulaşılmıştır.</p></abstract>
                                                                                                                                    <trans-abstract xml:lang="en">
                            <p>In this study, accelerated corrosion test is applied to 300 dosaged concretes whose sizes are 15cm cube. Reinforcement steel diameters of ø12, ø14 and ø16, respectively, were inserted into the middle points of the concrete. The concrete produced was cured for 28 days after being removed from the molds. In order to achive accelerated corrosion test, 30 V stress intensity is applied by DC power supply. The currents passing through the concretes were recorded with the help of ampere meter and various comparisons were made. It has been concluded that, the increase in the diameter of the reinforcement steel in the concrete can decrease the corrosion intensity of the concrete.</p></trans-abstract>
                                                            
            
                                                            <kwd-group>
                                                    <kwd>Beton</kwd>
                                                    <kwd>  Hızlandırılmış korozyon</kwd>
                                                    <kwd>  Doğru akım</kwd>
                                            </kwd-group>
                                                        
                                                                            <kwd-group xml:lang="en">
                                                    <kwd>Concrete</kwd>
                                                    <kwd>  Accelerated corrosion</kwd>
                                                    <kwd>  Dirrect current</kwd>
                                            </kwd-group>
                                                                                                            </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">[1] 	Song  H.W., Saraswathy V., “Corrosion monitoring of reinforced concrete structures – a review”, International Journal of Electrochemical Science, 2: 1-28, (2007).</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">[2] 	Elsener B., “Corrosion rate of steel in concrete-measurements beyond the tafel law”, Corrosion Science, 47: 3019–3033, (2005).</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">[3] 	Zhu W., François R., “Corrosion of the reinforcement and its influence on the residual structural performance of a 26-year-old corroded RC beam”, Construction and Building Materials, 51: 461–472, (2014).</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">[4] 	Bicer K., Yalciner H., Balkıs A.P., Kumbasaroglu A., “Effect of corrosion on flexural strength of reinforced concrete beams with polypropylene fibers”, Construction and Building Materials, 185: 574–588, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">[5] 	Cavaco E.S., Neves L.A.C., Casas, J.R., “Reliability-based approach to the robustness of corroded reinforced concrete structures”, Struct. Conc. 18 (2): 316–325, (2017).</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">[6] 	Cao C., Cheung M.M.S “Non-uniform rust expansion for chloride-induced pitting corrosion in RC structures”, Construction and Building Materials, 51: 75–81, (2014).</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">[7] 	Bazán A.M., Gálvez J.C, Reyes E., Galé-Lamuela D., “Study of the rust penetration and circumferential stresses in reinforced concrete at early stages of an accelerated corrosion test by means of combined SEM, EDS and strain gauges”, Construction and Building Materials, 184: 655–667, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">[8] 	Jinwei C., Chuanqing F., Hailong Y., Xianyu Jin., “Corrosion of steel embedded in mortar and concrete under different electrolytic accelerated corrosion methods” Construction and Building Materials 241 (11): 71-79, (2020).</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">[9] 	Fu C., Jin N., Ye H., Jin X., Dai W., “Corrosion characteristics of a 4-year naturally corroded reinforced concrete beam with load-induced transverse cracks”, Corrosion Science, 117: 11–23, (2017).</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">[10] 	Poupard O., L’Hostis V., Catinaud S., Petre-Lazar I., “Corrosion damage diagnosis of a reinforced concrete beam after 40 years natural exposure in marine environment”, Cem. Concr. Res., 36: 504–520, (2006).</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">[11] Andrade C., Keddam M., Nóvoa X.R., Pérez, M.C., Rangel, C.M., Takenouti H., “Electrochemical behaviour of steel rebars in concrete: influence of environmental factors and cement chemistry”, Electrochim. Acta 46: 3905–3912, (2001).</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">[12] Ye H., Jin N., Fu C., Jin X., ”Rust distribution and corrosion-induced cracking patterns of corner-located rebar in concrete cover”, Construction and Building Materials, 156: 684–691, (2017).</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">[13] Zhang R., Castel A., François R., “Concrete cover cracking with reinforcement corrosion of RC beam during chloride-induced corrosion process”, Cem. Concr. Res.,  40: 415–425, (2010).</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">[14] 	Ye H., Fu C., Jin, N., Jin, X., “Performance of reinforced concrete beams corroded under sustained service loads: a comparative study of two accelerated corrosion techniques”, Construction and Building Materials, 162: 286–297, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">[15]	Yuan Y., Ji Y., Shah S.P., “Comparison of two accelerated corrosion techniques for concrete structures”, ACI Struct. J. 104: 344, (2007).</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">[16] 	Lu Y., Hu J., Li S., Tang W., “Active and passive protection of steel reinforcement in concrete column using carbon fibre reinforced polymer against corrosion”, Electrochim. Acta 278: 124–136, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">[17] 	Wang X., Zhang X.G., Dai H., “Determination of residual cross-sectional areas of corroded bars in reinforced concrete structures using easy-to-measure variables”, Construction and Building Materials, 38: 846–853, (2013).</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">[18]  	Bazán A.M., Gálvez J.C., Reyes E., Galé-Lamuela D., “Study of the rust penetration and circumferential stresses in reinforced concrete at early stages of an accelerated corrosion test by means of combined SEM, EDS and strain gauges”, Construction and Building Materials, 184: 655–667, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">[19] 	El Maaddawy T.A., Soudki K.A., “Effectiveness of impressed current technique to simulate corrosion of steel reinforcement in concrete”, J. Mater. Civ. Eng, 15: 41–47, (2003).</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">[20] 	Imperatore S., Leonardi A., Rinaldi Z., “Mechanical behaviour of corroded rebars in reinforced concrete elements”, Lect. Notes Appl. Comput. Mech, 61: 207–220, (2012).</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">[21] 	Xia J., Jin W., Li L., “Performance of corroded reinforced concrete columns under the action of eccentric loads”, J. Mater. Civ. Eng, 28: 4015087, (2016).</mixed-citation>
                    </ref>
                                    <ref id="ref22">
                        <label>22</label>
                        <mixed-citation publication-type="journal">[22] 	Abosrra L., Ashour A.F., Youseffi M., “Corrosion of steel reinforcement in concrete of different compressive strengths”, Construction and Building Materials, 25: 3915–3925, (2011).</mixed-citation>
                    </ref>
                                    <ref id="ref23">
                        <label>23</label>
                        <mixed-citation publication-type="journal">[23] 	Lu Y., Hu J., Li S., Tang W., “Active and passive protection of steel reinforcement in concrete column using carbon fibre reinforced polymer against corrosion”, Electrochim. Acta, 278: 124–136, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref24">
                        <label>24</label>
                        <mixed-citation publication-type="journal">[24] 	Almusallam A.A., “Effect of degree of corrosion on the properties of reinforcing steel bars”, Construction and Building Materials, 15: 361–368, (2001).</mixed-citation>
                    </ref>
                                    <ref id="ref25">
                        <label>25</label>
                        <mixed-citation publication-type="journal">[25] 	Hocaoğlu İ., Uygunoğlu T., “Alternatif gerilim uygulanan betonlarda s/ç oranının ve hiperakışkanlaştırıcı oranının priz bitiş süresi ve basınç dayanımına etkilerinin araştırılması”, Journal of Polytechnic, ISSN: 1302-0900 (Print), ISSN: 2147-9429 (Online), (2019).</mixed-citation>
                    </ref>
                                    <ref id="ref26">
                        <label>26</label>
                        <mixed-citation publication-type="journal">[26] 	Topçu İ.B., Uygunoğlu T., Hocaoğlu İ., “Yüksek Fırın Cüruf Katkılı Çimento Pastalarının Elektriksel Özdirençlerinin Araştırılması”, Journal of Polytechnic, 21 (2): 257 – 264, (2018).</mixed-citation>
                    </ref>
                                    <ref id="ref27">
                        <label>27</label>
                        <mixed-citation publication-type="journal">[27] 	TS EN 197-1, “Çimento- Bölüm 1: Genel çimentolar- Bileşim, özellikler ve uygunluk kriterleri”, Türk Standartları Enstitüsü, Ankara, (2012).</mixed-citation>
                    </ref>
                                    <ref id="ref28">
                        <label>28</label>
                        <mixed-citation publication-type="journal">[28]  	Türkiye bina deprem yönetmeliği, 18 Mart 2018 tarihli ve 30364 sayılı mükerrer Resmi Gazete, Afet ve Acil Yönetimi Başkanlığı, Ankara, (2018.)</mixed-citation>
                    </ref>
                                    <ref id="ref29">
                        <label>29</label>
                        <mixed-citation publication-type="journal">[29] TS 708, “Beton çelik çubukları”, Türk Standartları Enstitüsü, Ankara, Mart (1996).</mixed-citation>
                    </ref>
                                    <ref id="ref30">
                        <label>30</label>
                        <mixed-citation publication-type="journal">[30]  TS 708, Çelik-Betonarme için donatı çeliği, Türk Standartları Enstitüsü, Ankara, (2010).</mixed-citation>
                    </ref>
                                    <ref id="ref31">
                        <label>31</label>
                        <mixed-citation publication-type="journal">[31] 	Topçu İ.B., Boğa A.R., “Çimento Tipinin Donatı Korozyonuna Etkisi”, 7. Ulusal Beton Kongresi, İstanbul, 301-310, (2007).</mixed-citation>
                    </ref>
                                    <ref id="ref32">
                        <label>32</label>
                        <mixed-citation publication-type="journal">[32] 	Boğa A.R., “Yüksek Fırın Cürufu ve Korozyon İnhibitörü Kullanımının Beton İçerisindeki Donat Korozyonuna ve Beton Özeliklerine Etkileri”, Doktora Tezi, ESOGÜ, İnşaat Mühendisliği Anabilim Dalı,  (2010).</mixed-citation>
                    </ref>
                                    <ref id="ref33">
                        <label>33</label>
                        <mixed-citation publication-type="journal">[33] 	Hocaoğlu İ., Topçu İ.B., “Effect of DC Current and NaCl Ratio on Accelerated Corrosion at Different Diameter of Steels”, BSEU Journal of Engıneerıng Research and Technology, 1: 18-23, (2020).</mixed-citation>
                    </ref>
                            </ref-list>