<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>saujs</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Sakarya University Journal of Science</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">2147-835X</issn>
                                                                                            <publisher>
                    <publisher-name>Sakarya University</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.16984/saufenbilder.529265</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Electrical Engineering</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Elektrik Mühendisliği</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                                                            <article-title>The Effect of GIBBS Factor on Transient Analysis in Underground Power Cables</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-5897-6274</contrib-id>
                                                                <name>
                                    <surname>Uyaroglu</surname>
                                    <given-names>Yılmaz</given-names>
                                </name>
                                                                    <aff>SAKARYA UNIVERSITY</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0001-7319-8861</contrib-id>
                                                                <name>
                                    <surname>Emiroglu</surname>
                                    <given-names>Selcuk</given-names>
                                </name>
                                                                    <aff>SAKARYA UNIVERSITY</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20191001">
                    <day>10</day>
                    <month>01</month>
                    <year>2019</year>
                </pub-date>
                                        <volume>23</volume>
                                        <issue>5</issue>
                                        <fpage>934</fpage>
                                        <lpage>941</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20190219">
                        <day>02</day>
                        <month>19</month>
                        <year>2019</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20190515">
                        <day>05</day>
                        <month>15</month>
                        <year>2019</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1997, Sakarya University Journal of Science</copyright-statement>
                    <copyright-year>1997</copyright-year>
                    <copyright-holder>Sakarya University Journal of Science</copyright-holder>
                </permissions>
            
                                                                                                                        <abstract><p>In thiswork, the transient over – voltage phenomena occurred at 34.5 kV AC undergroundcable transmission systems during the closure of the underground cables is tobe studied and simulated by using MATLAB program. Then, the transient voltageoccurred at the underground cables is analyzed by using modified Fouriertransform. The studied systems of underground cables are firstly modeled infrequency domain. Transient voltages induced at the sending-end and receiving-endterminals of an underground cable of transmission system are calculated infrequency domain and using inverse Fourier Transform, the sending end and receivingend voltages are obtained by converting to time domain. The effects of cablelength and source impedance on transient over – voltage phenomena atunderground cables are investigated. Also, the effects of GIBBS factor intransients are researched in order to eliminate GIBBS oscillations. Numericalsimulations are presented to demonstrate the transient voltages induced at theterminals of sending-end and receiving-end of an underground cable attransmission system and the effects of GIBBS factor.</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>Transient analysis</kwd>
                                                    <kwd>  underground cables</kwd>
                                                    <kwd>  Fourier transforms</kwd>
                                                    <kwd>  GIBBS oscillation</kwd>
                                            </kwd-group>
                            
                                                                                                                                                    </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">Y. Uyaroğlu, Switching Transients Analysis in Underground Power Cables. M.Sc.  Thesis, Sakarya University, 1997.(in Turkish)</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">L. M. Wedepohl and C. S. Indulkar, “Switching Overvoltages in Long Crossbonded Cable Systems Using the Fourier Transform,” IEEE Transactions on Power Apparatus and Systems, pp. 1476- 1480, July/August 1979.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">Ana Isabel Brito, V. Maló Machado, M.E. Almeida, M. Guerreiro das Neves, “Skin and proximity effects in the series-impedance of three-phase underground cables,” Electric Power Systems Research,130,132-138, 2016.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">W. D. Humpage, K. P. Wong, T. T. Nguyen, and D. Sutanto, “Z-transform electromagnetic transient analysis in power systems,” Proc. Inst. Elec. Eng., C, Gen. Trans. Dist., vol. 127, pp. 370-378, Nov. 1980.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">W. D. Humpage, K. P. Wong, T. T. Nguyen, “Z-transform electromagnetic transient analysis in crossbonded cable transmission systems,”  Proc. Inst Elec. Eng, C, Gen. Trans. Dist., vol. 128, pp. 55-62, 1981.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">T. Noda, A. Ramirez, “Z-transform based methods for electromagnetic transient simulations, ” IEEE Trans.on Delivery, vol. 22, no. 3, July 2007.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">I. Kocar, J. Mahseredjian, G. Olivier, “Weighting Method for Transient Analysis of Underground Cables,” IEEE Transactions on Power Delivery, vol. 23, no. 3, July 2008.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">B.A. Suleimanov, O.A. Dyshin, “Application of discrete wavelet transform to the solution of boundary value problems for quasi-linear parabolic equations,” Applied Mathematics and Computation 219 7036–7047, 2013.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Heng-Xu Ha, Yu-Zhen Tan, Bo Chen, and Z. Q. Bo, “A Novel Electro-magnetic Transient Analysis Method Based on Orthogonal Projection Approach,” Progress In Electromagnetics Research Symposium Proceedings, Moscow, Russia, August 18 -21, 2009.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">A. Semlyen and Mansour H. Abdel-Rahman, “A State Variable Approach for the Calculation of Switching Transients on a Power Transmission Line,” IEEE Trans. on Circuits and Systems, vol. cas. 29, no. 9, pp. 624-633, September 1982.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">L.M. Wedepohl , S.E.T. Mohamed, “Multiconductor Transmission Lines, Theory of Natural Modes and Fourier Integral Applied to Transient Analysis,” Proc.IEE ,Vol. 116., No 9., September 1969.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">L.M. Wedepohl , C.S. Indulkar, “Switching Overvoltages in Long Crossbonded Cable Systems Using the Fourier Transform,” IEEE  Transactions on Power Apparatus and Systems, Vol. PAS-98, No 4 July/August, 1974.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">C. Lanczos, “Applied Analysis”, Prentice-Hall 539 pp., 1956.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Ali Abdi, Seyed Mohammad Hosseini, “An investigation of resolution of 2-variate Gibbs phenomenon, ” Applied Mathematics and Computation 203, 714–732,2008.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">E. Berriochoa, A. Cachafeiro, J. Díaz, “Gibbs phenomenon in the Hermite interpolation on the circle,” Applied Mathematics and Computation, 253, 274-286, 2015.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">U. Ünver, “Transient Analysis of Cable Systems Including the effect of Nonlineer Protective Devices,” PhD. Thesis, University of Manchester Institute of Science and Technology, 1979.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>