Year 2020, Volume 15 , Issue 2, Pages 237 - 243 2020-11-29

Energy Resolution Dependent on K-parameter of EXOGAM2 Detector with Newly Developed NUMEXO2 Digital Electronics
Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü

Vakkas BOZKURT [1] , Sefa ERTURK [2] , Elif ŞAHİ̇N [3]


In this study, energy resolution dependent on K-Parameters (Trapezoidal filter system optimizing the count rate) of EXOGAM2 detector with newly developed NUMEXO2 digital electronics using 152Eu radioactive source measured and analysed. This experimental study was carried out at the GANIL (Grand Accelerature National d'Ions Lourd) nuclear research center in France. The measurement and analysis results for different K parameters using a 152Eu radioactive source with low and high gamma energy levels were performed for two EXOGAM2 detectors. Without applying any K parameter, the resolution values expressed by FWHM for the 1.EXOGAM2 detector are measured as 2.360% FWHM for (344.2785 keV), 2.820% FWHM for (1408.006 keV), and 2.451% FWHM for (344.2785 keV), 2.975%FWHM for (1408.006 keV) for the 2.EXOGAM2 detector, respectively. For different K parameters (K=2µs, K=5µs ve K=10µs) detail results are shown below.
Bu çalışmada, yeni geliştirilen dijital elektronik NUMEXO2 dijital elektronik ile EXOGAM2(EXOtic GAMma array spectrometer) dedektörünün K-Parametrelerine (sayım oranını optimize eden Trapezoidal filtre sistemi) bağlı enerji çözünürlüğü için 152Eu radyoaktif kaynak kullanılarak ölçüm ve analiz yapılmıştır. Yapılan bu deneysel çalışma Fransa’da bulunan GANIL (Grand Accelerature National d’Ions Lourd) nükleer araştırma merkezinde gerçekleştirilmiştir. Düşük ve yüksek gama enerji seviyesine sahip 152Eu radyoaktif kaynak kullanılarak farklı K-parametreleri için gerçekleştirilen ölçüm ve analiz sonuçları iki EXOGAM2 dedektörü için gerçekleştirilmiştir. Herhangi bir K-parametresi uygulamadan 1.EXOGAM2 dedektörü için FWHM ile ifade edilen çözünürlük değerleri sırası ile (344. 2785 keV) için 2.360% FWHM, (1408.006 keV) için 2.820% FWHM olarak ölçülürken 2.EXOGAM2 dedektörü için ise sırasıyla 2.451% FWHM ve 2.975% FWHM olarak ölçülmüştür. Farklı K-parametreleri (K=2µs, K=5µs ve K=10µs) için ise sonuçlar detayları ile aşağıda gösterilmiştir.
  • [1] R. H. Pehl, “Radiation damage of germanium detectors”, in Proc. Gamma Ray Spectroscopy in Astrophysics Symposium, Greenbelt, Maryland, 1978, pp. 1-10.
  • [2] G. de Angelis, A. Bracco, D. Curien, “The EUROBALL gamma ray detector spectrometer”, Europhysics News, 34 (5), 181-185, 2003.
  • [3] F. S. Goulding, D. A. Landis, N. Madden, M. Maier, H. Yaver Goulding, “GAMMASPHERE- Overview of detector and signal processing system”, in Proc. IEEE Nuclear Science Symposium and Medical Imaging Conference Record, San Francisco, 1995, pp. 432-436.
  • [4] J. Erberth et al, “Miniball: A gamma-ray spectrometer with position-sensitive Ge detectors for nuclear structure studies at REX-ISOLDE”, in Proc. Conference of Frontiers of Nuclear Structure, Berkeley, California, 2003, pp. 349-356.
  • [5] G. de France, “High resolution gamma-ray spectroscopy at GANIL”, in Proc. 36th Brazilian Workshop on Nuclear Physics, Sao Paulo, 2014, pp. 10-16.
  • [6] S. Akkoyun et al., “AGATA - Advanced gamma tracking array”, Nuclear Instruments and Methods in Physics Research, 668, 26-58, 2012.
  • [7] C. W. Beausang et al, “GRETA. The gamma-ray energy-tracking array. Status of the development and physics opportunities”, Nuclear Instruments and Methods in Physics research Section B: Beam Interactions with Materials and Atoms, 204, 666-670, 2003.
  • [8] F. J. Egea et al.. “A new front-end high-resolution sampling board for the new-generation electronics of EXOGAM2 and NEDA detectors”, IEEE Transactions On Nuclear Science, 62 (3), 1056-162, 2015.
  • [9] F. J. Egea, et al. “Digital front-end electronics for the neutron detector NEDA”, IEEE Transactions On Nuclear Science, 62 (3), 1063-1069, 2015.
  • [10] G.. F. Knoll, Radiation Detection and Measurement. New York: John Wiley & Sons, Inc., 2010, 830p.
Primary Language tr
Subjects Physics, Applied
Journal Section Makaleler
Authors

Orcid: 0000-0003-4651-0447
Author: Vakkas BOZKURT (Primary Author)
Institution: NIGDE OMER HALISDEMIR UNIVERSITY, FACULTY OF SCIENCE AND LETTERS
Country: Turkey


Orcid: 0000-0003-4051-9096
Author: Sefa ERTURK
Institution: NİĞDE ÖMER HALİSDEMİR ÜNİVERSİTESİ
Country: Turkey


Orcid: 0000-0002-6008-4272
Author: Elif ŞAHİ̇N
Institution: İZMİR YÜKSEK TEKNOLOJİ ENSTİTÜSÜ
Country: Turkey


Supporting Institution TÜBİTAK
Project Number 114F473
Thanks Bu çalışma TÜBİTAK 114F473 nolu proje trafında desteklenmiştir bu destek için TÜBİTAK’a teşekkür ederiz. Ayrıca bu çalışmayı gerçekleştirdiğimiz GANIL çalışanları Gilles de FRANCE, Michel TRIPON, Frederric SAILLANT ve diğer laboratuvar çalışanlarına teşekkür ederiz.
Dates

Publication Date : November 29, 2020

Bibtex @research article { sdufeffd799021, journal = {Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi}, issn = {}, eissn = {1306-7575}, address = {}, publisher = {Süleyman Demirel University}, year = {2020}, volume = {15}, pages = {237 - 243}, doi = {10.29233/sdufeffd.799021}, title = {Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü}, key = {cite}, author = {Bozkurt, Vakkas and Erturk, Sefa and Şahi̇̇n, Elif} }
APA Bozkurt, V , Erturk, S , Şahi̇̇n, E . (2020). Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü . Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi , 15 (2) , 237-243 . DOI: 10.29233/sdufeffd.799021
MLA Bozkurt, V , Erturk, S , Şahi̇̇n, E . "Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü" . Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi 15 (2020 ): 237-243 <https://dergipark.org.tr/en/pub/sdufeffd/issue/57875/799021>
Chicago Bozkurt, V , Erturk, S , Şahi̇̇n, E . "Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü". Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi 15 (2020 ): 237-243
RIS TY - JOUR T1 - Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü AU - Vakkas Bozkurt , Sefa Erturk , Elif Şahi̇̇n Y1 - 2020 PY - 2020 N1 - doi: 10.29233/sdufeffd.799021 DO - 10.29233/sdufeffd.799021 T2 - Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi JF - Journal JO - JOR SP - 237 EP - 243 VL - 15 IS - 2 SN - -1306-7575 M3 - doi: 10.29233/sdufeffd.799021 UR - https://doi.org/10.29233/sdufeffd.799021 Y2 - 2020 ER -
EndNote %0 Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü %A Vakkas Bozkurt , Sefa Erturk , Elif Şahi̇̇n %T Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü %D 2020 %J Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi %P -1306-7575 %V 15 %N 2 %R doi: 10.29233/sdufeffd.799021 %U 10.29233/sdufeffd.799021
ISNAD Bozkurt, Vakkas , Erturk, Sefa , Şahi̇̇n, Elif . "Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü". Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi 15 / 2 (November 2020): 237-243 . https://doi.org/10.29233/sdufeffd.799021
AMA Bozkurt V , Erturk S , Şahi̇̇n E . Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü. Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi. 2020; 15(2): 237-243.
Vancouver Bozkurt V , Erturk S , Şahi̇̇n E . Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü. Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi. 2020; 15(2): 237-243.
IEEE V. Bozkurt , S. Erturk and E. Şahi̇̇n , "Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü", Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi, vol. 15, no. 2, pp. 237-243, Nov. 2020, doi:10.29233/sdufeffd.799021