<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20241031//EN"
        "https://jats.nlm.nih.gov/publishing/1.4/JATS-journalpublishing1-4.dtd">
<article  article-type="research-article"        dtd-version="1.4">
            <front>

                <journal-meta>
                                                                <journal-id>selcuk dent j</journal-id>
            <journal-title-group>
                                                                                    <journal-title>Selcuk Dental Journal</journal-title>
            </journal-title-group>
                                        <issn pub-type="epub">2148-7529</issn>
                                                                                            <publisher>
                    <publisher-name>Selcuk University</publisher-name>
                </publisher>
                    </journal-meta>
                <article-meta>
                                        <article-id pub-id-type="doi">10.15311/selcukdentj.1435344</article-id>
                                                                <article-categories>
                                            <subj-group  xml:lang="en">
                                                            <subject>Prosthodontics</subject>
                                                    </subj-group>
                                            <subj-group  xml:lang="tr">
                                                            <subject>Protez</subject>
                                                    </subj-group>
                                    </article-categories>
                                                                                                                                                        <title-group>
                                                                                                                        <article-title>A tipi silikonların temas açısı ve çekme testi ile karşılaştırılması</article-title>
                                                                                                                                                                                                <trans-title-group xml:lang="en">
                                    <trans-title>Comparison of type A silicones with contact angle and tensile test</trans-title>
                                </trans-title-group>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0000-0003-0927-6962</contrib-id>
                                                                <name>
                                    <surname>Demir</surname>
                                    <given-names>Necla</given-names>
                                </name>
                                                                    <aff>selçuk üniversitesi diş hekimliği fakültesi</aff>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                    <contrib-id contrib-id-type="orcid">
                                        https://orcid.org/0009-0007-6146-8917</contrib-id>
                                                                <name>
                                    <surname>Çapar</surname>
                                    <given-names>Zişan</given-names>
                                </name>
                                                                    <aff>Selçuk Üniversitesi Diş Hekimliği Fakültesi</aff>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20241223">
                    <day>12</day>
                    <month>23</month>
                    <year>2024</year>
                </pub-date>
                                        <volume>11</volume>
                                        <issue>3</issue>
                                        <fpage>282</fpage>
                                        <lpage>286</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20240211">
                        <day>02</day>
                        <month>11</month>
                        <year>2024</year>
                    </date>
                                                    <date date-type="accepted" iso-8601-date="20240415">
                        <day>04</day>
                        <month>15</month>
                        <year>2024</year>
                    </date>
                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 2014, Selcuk Dental Journal</copyright-statement>
                    <copyright-year>2014</copyright-year>
                    <copyright-holder>Selcuk Dental Journal</copyright-holder>
                </permissions>
            
                                                                                                <abstract><p>Amaç: Bu çalışmanın amacı sürfaktan ve nanopartikül içeriği farklı a tipi silikon ölçü materyallerine temas açısı/ıslanabilirliği (contact angle) ve çekme testi (tensile strenght) uygulanarak materyallerin çekme dayanıklılığı ve hidrofilik özelliklerini değerlendirmektir.Yöntem: Çalışmamızda a tipi polivinil siloksan ölçü materyallerinden nanopartikül ve sürfaktan içerikleri farklı olan Zhermack Elite Hd (Ivoclar, Vivadent, Lienchenstein, Germany) ile Imicryl Spirias (Konya, Türkiye) kullanılmıştır. Temas açısı testi ve çekme testi için 20’şer örnek hazırlanmıştır. Dataphysics Oca 50 micro cihazında başlangıç olarak 0.138 sn. ve bitiş olarak 82.8. sn.deki temas açısı ölçümleri yapılmıştır. DVT GPE 13888 YBS cihazda 50 mm/dk hızda çekme testi uygulanmıştır. Numunelerin koptuğu anda uygulanan kuvvet Fmax (Mpa), çekme uzama yüzdesi (ΔL) ve elastik modülüsü (E= N/mm²) kayıt edilmiştir. Sonuçlar IBM SPSS V23 ve RStudio ile analiz edilmiştir. Bulgular: Temas açısı ölçüm değerleri arasındaki fark istatistiksel olarak anlamlı bulunmuştur (p</p></abstract>
                                                                                                                                    <trans-abstract xml:lang="en">
                            <p>Amaç: Bu çalışmanın amacı sürfaktan ve nanopartikül içeriği farklı a tipi silikon ölçü materyallerine temas açısı/ıslanabilirliği (contact angle) ve çekme testi (tensile strenght) uygulanarak materyallerin çekme dayanıklılığı ve hidrofilik özelliklerini değerlendirmektir.Gereç ve Yöntemler: Çalışmamızda a tipi polivinil siloksan ölçü materyallerinden nanopartikül ve sürfaktan içerikleri farklı olan Zhermack Elite Hd (Ivoclar, Vivadent, Lienchenstein, Germany) ile Imicryl Spirias (Konya, Türkiye) kullanılmıştır. Temas açısı testi ve çekme testi için 20’şer örnek hazırlanmıştır. Dataphysics Oca 50 micro cihazında başlangıç olarak 0.138 sn. ve bitiş olarak 82.8. sn.deki temas açısı ölçümleri yapılmıştır. DVT GPE 13888 YBS cihazda 50 mm/dk hızda çekme testi uygulanmıştır. Numunelerin koptuğu anda uygulanan kuvvet Fmax (Mpa), çekme uzama yüzdesi (ΔL) ve elastik modülüsü (E= N/mm²) kayıt edilmiştir. Sonuçlar IBM SPSS V23 ve RStudio ile analiz edilmiştir. Bulgular: Temas açısı ölçüm değerleri arasındaki fark istatistiksel olarak anlamlı bulunmuştur (p</p></trans-abstract>
                                                            
            
                                                            <kwd-group>
                                                    <kwd>Çekme testi</kwd>
                                                    <kwd>  polivinil siloksan</kwd>
                                                    <kwd>  temas açısı testi</kwd>
                                            </kwd-group>
                                                        
                                                                            <kwd-group xml:lang="en">
                                                    <kwd>Tensile test</kwd>
                                                    <kwd>  polyvinyl siloxane</kwd>
                                                    <kwd>  contact angle test</kwd>
                                            </kwd-group>
                                                                                                            </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">1. O&#039;Brien WJ. Dental materials and their selection: Quintessence Chicago; 2002.</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">2. Jain AR, Nallaswamy D, Ariga P, Ganapathy D. Determination of correlation of width of Maxillary Anterior Teeth using Extraoral and Intraoral Factors in Indian Population: A systematic review. World J Dent. 2018;9(1):68-75.</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">3. Hamalian TA, Nasr E, Chidiac JJ. Impression materials in fixed prosthodontics: influence of choice on clinical procedure. Journal of Prosthodontics: Implant, Esthetic and Reconstructive Dentistry. 2011;20(2):153-60.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">4. BOYACI BK, KOCACIKLI M. Elastomerik Ölçü Materyallerinde Güncel Gelişmeler. ADO Klinik Bilimler Dergisi. 2017;8(1):1535-46.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">5. Sheta MS, El-Shorbagy ZA, Karim UMA, Abd-Alla S. Laboratory comparative study of wettability, dimensional changes, flexibility and tear resistance of two recent elastomeric impression materials. Tanta Dental Journal. 2017;14(2):89-95.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">6. Chee WW, Donovan TE. Polyvinyl siloxane impression materials: a review of properties and techniques. The Journal of prosthetic dentistry. 1992;68(5):728-32.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">7. Rubel BS. Impression materials: a comparative review of impression materials most commonly used in restorative dentistry. Dental Clinics of North America. 2007;51(3):629-42.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">8. Sheta MS, El-Shorbagy ZA, Abdel Karim UM, Abd-Alla S. Laboratory comparative study of wettability, dimensional changes, flexibility and tear resistance of two recent elastomeric impression materials. Tanta Dental Journal. 2017;14(2):89-95.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">9. Menees TS, Radhakrishnan R, Ramp LC, Burgess JO, Lawson NC. Contact angle of unset elastomeric impression materials. The Journal of prosthetic dentistry. 2015;114(4):536-42.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">10. Nassar U, Tavoossi F, Pan YW, Milavong-Viravongsa N, Heo G, Nychka JA. Comparison of the contact angle of water on set elastomeric impression materials. J Can Dent Assoc. 2018;84(i6):1488-2159.</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">11. Hayward JA, Chapman D. Biomembrane surfaces as models for polymer design: the potential for haemocompatibility. Biomaterials. 1984;5(3):135-42.</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">12. Clancy JM, Scandrett FR, Ettinger RL. Long‐term dimensional stability of three current elastomers. Journal of oral rehabilitation. 1983;10(4):325-33.</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">13. Sawyer HF, Dilts WE, Aubrey ME, Neiman R. Accuracy of casts produced from the three classes of elastomer impression materials. The Journal of the American Dental Association. 1974;89(3):644-8.</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">14. Norling BK, Reisbick MH. The effect of nonionic surfactants on bubble entrapment in elastomeric impression materials. The Journal of Prosthetic Dentistry. 1979;42(3):342-7.</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">15. Grundke K, Michel S, Knispel G, Grundler A. Wettability of silicone and polyether impression materials: Characterization by surface tension and contact angle measurements. Colloids and Surfaces A: Physicochemical and Engineering Aspects. 2008;317(1-3):598-609.</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">16. Lu H, Nguyen B, Powers JM. Mechanical properties of 3 hydrophilic addition silicone and polyether elastomeric impression materials. The Journal of prosthetic dentistry. 2004;92(2):151-4.</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">17. Perakis N, Belser UC, Magne P. Final impressions: a review of material properties and description of a current technique. International Journal of Periodontics &amp; Restorative Dentistry. 2004;24(2).</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">18. Barszczewska-Rybarek IM. A guide through the dental dimethacrylate polymer network structural characterization and interpretation of physico-mechanical properties. Materials. 2019;12(24):4057.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">19. Kato K, Ikeda Y, Ito K. Direct determination of cross-link density and its correlation with the elastic modulus of a gel with slidable cross-links. ACS Macro Letters. 2019;8(6):700-4.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">20. Apinsathanon P, Bhattarai BP, Suphangul S, Wongsirichat N, Aimjirakul N. Penetration and tensile strength of various impression materials of vinylsiloxanether, polyether, and polyvinylsiloxane impression materials. European Journal of Dentistry. 2021;16(02):339-45.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">21. Karayazgan-Saracoğlu B. Silika ile güçlendirilmiş maksillofasiyal silikon elastomerlerin fiziksel özelliklerinin değerlendirilmesi. Cumhuriyet Dent J. 2010;13(1):34-9.</mixed-citation>
                    </ref>
                                    <ref id="ref22">
                        <label>22</label>
                        <mixed-citation publication-type="journal">22. Andreopoulos A, Evangelatou M. Evaluation of various reinforcements for maxillofacial silicone elastomers. Journal of biomaterials applications. 1994;8(4):344-60.</mixed-citation>
                    </ref>
                                    <ref id="ref23">
                        <label>23</label>
                        <mixed-citation publication-type="journal">23. Andreopoulos A, Evangelatou M, Tarantili P. Properties of maxillofacial silicone elastomers reinforced with silica powder. Journal of biomaterials applications. 1998;13(1):66-73.</mixed-citation>
                    </ref>
                                    <ref id="ref24">
                        <label>24</label>
                        <mixed-citation publication-type="journal">24. Aidasani AN, Jain S, Hassan S, Sharma A, Shanthi C, Fere S. Comparative Evaluation of the Rigidity and Accuracy of Different Elastomeric Impression Materials with Open Tray Implant Level Impression Technique-An In vitro Study. Journal of Pharmacy &amp; Bioallied Science. 2023 Jul;15(Suppl 2): S1262-S1265.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>
