Abstract

Turkish Seismic Code stipulates capacity design procedure for the calculation of design shear force of RC beams and columns. Therefore, the plastic hinge moment capacity (Mp) at the ends of columns must be determined as accurately as possible. Turkish Seismic Design Code recommends an increase of 40% in ultimate moment capacity (Mr) to obtain the plastic hinge moment capacity (Mp), unless a detailed calculation is carried out. However, this recommendation remains insufficient in attaining plastic hinge moment capacity for high levels of axial load.
In this study, new analytical equations have been derived to obtain the plastic hinge moment capacity of rectangular RC columns in an accurate and practical way. Plastic hinge moment capacity of columns calculated with the proposed equations is compared to the capacity obtained from experimental results. It is shown that the proposed equations yield accurate results

Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns

Year 2009, Volume: 20 Issue: 100, 1293 - 1312, 01.05.2009

Abstract

-

There are 0 citations in total.

Details

Primary Language English
Subjects Engineering
Journal Section Articles
Authors

Cem Aydemir This is me

Mustafa Zorbozan This is me

Sema Noyan Alacalı This is me

Publication Date May 1, 2009
Submission Date June 18, 2015
Published in Issue Year 2009 Volume: 20 Issue: 100

Cite

APA Aydemir, C., Zorbozan, M., & Alacalı, S. N. (2009). Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi, 20(100), 1293-1312.
AMA Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. May 2009;20(100):1293-1312.
Chicago Aydemir, Cem, Mustafa Zorbozan, and Sema Noyan Alacalı. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi 20, no. 100 (May 2009): 1293-1312.
EndNote Aydemir C, Zorbozan M, Alacalı SN (May 1, 2009) Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi 20 100 1293–1312.
IEEE C. Aydemir, M. Zorbozan, and S. N. Alacalı, “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”, Teknik Dergi, vol. 20, no. 100, pp. 1293–1312, 2009.
ISNAD Aydemir, Cem et al. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi 20/100 (May 2009), 1293-1312.
JAMA Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. 2009;20:1293–1312.
MLA Aydemir, Cem et al. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi, vol. 20, no. 100, 2009, pp. 1293-12.
Vancouver Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. 2009;20(100):1293-312.