Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones

Year 2022, Volume: 8 Issue: 2, 249 - 267, 11.03.2022
https://doi.org/10.18186/thermal.1086236

Abstract

Thermal insulation is one of the most effective methods of reducing energy consumption in buildings. Therefore, the parameters influencing the optimum insulation thickness are widely investigated. In this study, the optimum insulation thickness is obtained using the life cycle analysis method and the genetic algorithm by considering the size of the heating and cooling systems as an optimization variable, which has not been addressed in the earlier researches. Furthermore, the effect of the climate conditions on the optimum insulation thickness is comprehensively studied using five different climate zones, including Hot-Dry, Cold-Dry, Moderate-Humid, Hot-semi Humid, and Hot-Humid. It is found that the optimum thickness of expanded polystyrene insulation increases between 5%-19% considering the size variation of the heating systems including the central heating system and wall-hung gas boilers. By size variation of the cooling systems including the evaporative cooler and split air conditioner, this increase is between 8-19%. This is because the cost reduction due to the reduction of the required size of the heating and cooling systems can be expended for insulating the building with larger thickness which results in lower energy consumption. Based on the obtained results, the energy cost saving increases between 3.5%-14.5% and also, the payback period decreases about 1 to 3 months, depending on the considered heating and cooling systems and climate zone. The results confirm that the optimum insulation thickness can be determined with significant inaccuracy, ignoring the size variation of the heating and cooling systems as a result of thermal insulation.

References

  • The article references can be accessed from the .pdf file.
Year 2022, Volume: 8 Issue: 2, 249 - 267, 11.03.2022
https://doi.org/10.18186/thermal.1086236

Abstract

References

  • The article references can be accessed from the .pdf file.
There are 1 citations in total.

Details

Primary Language English
Subjects Thermodynamics and Statistical Physics
Journal Section Articles
Authors

Maryam Karamı This is me 0000-0003-4771-2446

Ehsan Anbarzadeh This is me 0000-0003-0522-2502

Shahram Delfanı This is me 0000-0002-3077-6366

Publication Date March 11, 2022
Submission Date September 7, 2020
Published in Issue Year 2022 Volume: 8 Issue: 2

Cite

APA Karamı, M., Anbarzadeh, E., & Delfanı, S. (2022). Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering, 8(2), 249-267. https://doi.org/10.18186/thermal.1086236
AMA Karamı M, Anbarzadeh E, Delfanı S. Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering. March 2022;8(2):249-267. doi:10.18186/thermal.1086236
Chicago Karamı, Maryam, Ehsan Anbarzadeh, and Shahram Delfanı. “Effect of HVAC System Size on the Optimum Insulation Thickness of the Buildings in Different Climate Zones”. Journal of Thermal Engineering 8, no. 2 (March 2022): 249-67. https://doi.org/10.18186/thermal.1086236.
EndNote Karamı M, Anbarzadeh E, Delfanı S (March 1, 2022) Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering 8 2 249–267.
IEEE M. Karamı, E. Anbarzadeh, and S. Delfanı, “Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones”, Journal of Thermal Engineering, vol. 8, no. 2, pp. 249–267, 2022, doi: 10.18186/thermal.1086236.
ISNAD Karamı, Maryam et al. “Effect of HVAC System Size on the Optimum Insulation Thickness of the Buildings in Different Climate Zones”. Journal of Thermal Engineering 8/2 (March 2022), 249-267. https://doi.org/10.18186/thermal.1086236.
JAMA Karamı M, Anbarzadeh E, Delfanı S. Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering. 2022;8:249–267.
MLA Karamı, Maryam et al. “Effect of HVAC System Size on the Optimum Insulation Thickness of the Buildings in Different Climate Zones”. Journal of Thermal Engineering, vol. 8, no. 2, 2022, pp. 249-67, doi:10.18186/thermal.1086236.
Vancouver Karamı M, Anbarzadeh E, Delfanı S. Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering. 2022;8(2):249-67.

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering