Araştırma Makalesi

Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods

Cilt: 11 Sayı: 2 4 Haziran 2023
PDF İndir
EN

Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods

Öz

Grid-tied inverters play an essential role in the power systems that are widely used to benefit from these energy systems. A filter is used between the inverter and the grid to suppress the harmonics of the current generated from the inverters. Various feedback strategies have been reported to regulate the dynamics of grid-connected systems. In this study, different control strategies are investigated to analyze the performance of the grid -connected inverter equipped with an LCL filter. The traditional proportional-integral-derivate (PID) controller, siding mode control (SMC), and model predictive control (MPC) is considered to perform the comparison work. The simulation works are conducted using MATLAB, and simulation works verify theoretical concepts.

Anahtar Kelimeler

Kaynakça

  1. D. M. C. Milbradt, G. V. Hollweg, P. J. D. de Oliveira Evald, W. B. da Silveira, and H. A. Gründling, “A robust adaptive One Sample Ahead Preview controller for grid-injected currents of a grid-tied power converter with an LCL filter,” Int. J. Electr. Power Energy Syst., vol. 142, no. May, 2022, doi: 10.1016/j.ijepes.2022.108286.
  2. D. Sgrò, S. A. Souza, F. L. Tofoli, R. P. S. Leão, and A. K. R. Sombra, “An integrated design approach of LCL filters based on nonlinear inductors for grid-connected inverter applications,” Electr. Power Syst. Res., vol. 186, no. May, p. 106389, 2020, doi: 10.1016/j.epsr.2020.106389.
  3. X. Q. Guo, W. Y. Wu, and H. R. Gu, “Modeling and simulation of direct output current control for LCL-interfaced grid-connected inverters with parallel passive damping,” Simul. Model. Pract. Theory, vol. 18, no. 7, pp. 946–956, 2010, doi: 10.1016/j.simpat.2010.02.010.
  4. C. C. Gomes, A. F. Cupertino, and H. A. Pereira, “Damping techniques for grid-connected voltage source converters based on LCL filter: An overview,” Renew. Sustain. Energy Rev., vol. 81, no. 2018, pp. 116–135, 2018, doi: 10.1016/j.rser.2017.07.050.
  5. C. Gurrola-Corral, J. Segundo, M. Esparza, and R. Cruz, “Optimal LCL-filter design method for grid-connected renewable energy sources,” Int. J. Electr. Power Energy Syst., vol. 120, no. 2020, pp. 1–14, 2020, doi: 10.1016/j.ijepes.2020.105998.
  6. J. Zhao, W. Wu, Z. Shuai, A. Luo, H. S. H. Chung, and F. Blaabjerg, “Robust Control Parameters Design of PBC Controller for LCL-Filtered Grid-Tied Inverter,” IEEE Trans. Power Electron., vol. 35, no. 8, pp. 8102–8115, 2020, doi: 10.1109/TPEL.2019.2963200.
  7. M. I. Solihin, L. F. Tack, and M. L. Kean, “Tuning of PID Controller Using Particle Swarm Optimization (PSO),” Int. J. Adv. Sci. Eng. Inf. Technol., vol. 1, no. 4, p. 458, 2011, doi: 10.18517/ijaseit.1.4.93.
  8. T. Adel and C. Abdelkader, “A Particle Swarm Optimization approach for optimum design of PID controller for nonlinear systems,” in 2013 International Conference on Electrical Engineering and Software Applications, ICEESA 2013, 2013, pp. 1–4, doi: 10.1109/ICEESA.2013.6578478.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Mühendisliği

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

30 Mayıs 2023

Yayımlanma Tarihi

4 Haziran 2023

Gönderilme Tarihi

13 Eylül 2022

Kabul Tarihi

9 Şubat 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 11 Sayı: 2

Kaynak Göster

APA
Demir, E., Gülbudak, O., & Gökdağ, M. (2023). Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods. Balkan Journal of Electrical and Computer Engineering, 11(2), 163-171. https://doi.org/10.17694/bajece.1174749
AMA
1.Demir E, Gülbudak O, Gökdağ M. Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods. Balkan Journal of Electrical and Computer Engineering. 2023;11(2):163-171. doi:10.17694/bajece.1174749
Chicago
Demir, Ekrem, Ozan Gülbudak, ve Mustafa Gökdağ. 2023. “Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods”. Balkan Journal of Electrical and Computer Engineering 11 (2): 163-71. https://doi.org/10.17694/bajece.1174749.
EndNote
Demir E, Gülbudak O, Gökdağ M (01 Haziran 2023) Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods. Balkan Journal of Electrical and Computer Engineering 11 2 163–171.
IEEE
[1]E. Demir, O. Gülbudak, ve M. Gökdağ, “Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods”, Balkan Journal of Electrical and Computer Engineering, c. 11, sy 2, ss. 163–171, Haz. 2023, doi: 10.17694/bajece.1174749.
ISNAD
Demir, Ekrem - Gülbudak, Ozan - Gökdağ, Mustafa. “Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods”. Balkan Journal of Electrical and Computer Engineering 11/2 (01 Haziran 2023): 163-171. https://doi.org/10.17694/bajece.1174749.
JAMA
1.Demir E, Gülbudak O, Gökdağ M. Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods. Balkan Journal of Electrical and Computer Engineering. 2023;11:163–171.
MLA
Demir, Ekrem, vd. “Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods”. Balkan Journal of Electrical and Computer Engineering, c. 11, sy 2, Haziran 2023, ss. 163-71, doi:10.17694/bajece.1174749.
Vancouver
1.Ekrem Demir, Ozan Gülbudak, Mustafa Gökdağ. Performance Evaluation of Three-Phase Grid-Connected Inverter with Various Control Methods. Balkan Journal of Electrical and Computer Engineering. 01 Haziran 2023;11(2):163-71. doi:10.17694/bajece.1174749

All articles published by BAJECE are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.Creative Commons Lisans