Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor

Öz

This paper presents the cross saturation effect on a specially designed spoke type permanent magnet synchronous motor (PMSM) for the sensorless vector control. The cross saturation effect becomes very important where the sensorless control algorithm is used. Accurate flux linkage modeling is required to obtain a satisfactory position estimation and eventually minimum induced torque error. The magnetic saturation is the most impacting parameters affecting the position error. Since the Ld and Lq inductance difference is generally less than 5% in the spoke type PMSM, the accurate estimation of the cross saturation is critical for the sensorless vector control.  In this paper, the designed PMSM has the Ld and Lq difference in 15% level even for the overload capacity. So it is even possible to operate the motor in the transient modes with the overload capacity by estimating right cross saturation effect with certain time limits. The mapping of the inductances and efficiency are obtained by using Finite element method and presented in the paper. Some experimental results are also given such as efficiency and power-speed variation at the constant torque.

Anahtar Kelimeler

Kaynakça

  1. K. Kurihara, M.A. Rahman, “High-Efficiency Line-Start Interior Permanent-Magnet Synchronous Motors”, IEEE Transactions on Industrial Applications, Vol.40, No.3, 2004, pp.789-796.
  2. A. Rahideh, A. Rahideh, M. Karimi, A. Shakeri, M. Azadi, “High Performance Direct Torque Control of a PMSM Using Fuzzy Logic And Genetic Algorithm”, IEEE International Conference on Electric Machines & Drives, Antalya, TURKEY, 2007.
  3. J. Simanek, J. Novak, O. Cerny, R. Dolecek, “FOC and Flux Weakening for Traction Drive with Permanent Magnet Synchronous Motor”, Proceedings of IEEE International Symposium on Industrial Electronics, Cambridge, UK, 2008.
  4. E. Fuchs, E. Erdelyi “Nonlinear Theory of Turboalternators, Part II. Load Dependent Synchronous Reactances”, IEEE Transactions on Power Apparratus and Systems, Vol. 92, No.2, 1973, pp.592–599.
  5. M. Kamoun, M. Poloujadoff, “Experimental Study of The Effect of Saturation on The Steady State Operation of a Salient Pole Microalternator”, Electrical Machines and Power Systems, Vol.10, 1985, pp.325–334.
  6. K. Saleh, M. Sumner, “Sensorless Speed Control of Five-Phase PMSM Drives with Low Current Distortion”, Electrical Engineering, 2017, pp.1-18. B. Stumberger, G. Stumberger, D. Dolinar, A. Hamler, M. Trlep, “Evaluation of Saturation and Cross-Magnetization Effects in Interior Permanent-Magnet Synchronous Motor”, IEEE Transactions on Industrial Applications, Vol.39, No.5, 2003, pp.1264–1271.
  7. A.M. El-Serafi, A.S. Abdallah, M.K. El-Sherbiny, E. Badawy, “Experimental Study of The Saturation and the Cross-Magnetizing Phenomenon in Saturated Synchronous Machines”, IEEE Transactions on Energy Conversion, Vol.2, No.4, 1988, pp.815–823.
  8. E. Levi, V.A. Levi, “Impact of Dynamic Cross-Saturation on Accuracy of Saturated Synchronous Machine Models”, IEEE Transactions on Energy Conversion, Vol.15, No.2, 2000, pp.224–230.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Murat İmeryüz Bu kişi benim

Cihad Ekin Bu kişi benim
Türkiye

Yayımlanma Tarihi

31 Temmuz 2018

Gönderilme Tarihi

1 Mayıs 2018

Kabul Tarihi

10 Haziran 2018

Yayımlandığı Sayı

Yıl 2018 Cilt: 6 Sayı: 3

Kaynak Göster

APA
Ergene, L. T., İmeryüz, M., & Ekin, C. (2018). Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor. Balkan Journal of Electrical and Computer Engineering, 6(3), 153-158. https://doi.org/10.17694/bajece.426284
AMA
1.Ergene LT, İmeryüz M, Ekin C. Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor. Balkan Journal of Electrical and Computer Engineering. 2018;6(3):153-158. doi:10.17694/bajece.426284
Chicago
Ergene, Lale T., Murat İmeryüz, ve Cihad Ekin. 2018. “Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor”. Balkan Journal of Electrical and Computer Engineering 6 (3): 153-58. https://doi.org/10.17694/bajece.426284.
EndNote
Ergene LT, İmeryüz M, Ekin C (01 Temmuz 2018) Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor. Balkan Journal of Electrical and Computer Engineering 6 3 153–158.
IEEE
[1]L. T. Ergene, M. İmeryüz, ve C. Ekin, “Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor”, Balkan Journal of Electrical and Computer Engineering, c. 6, sy 3, ss. 153–158, Tem. 2018, doi: 10.17694/bajece.426284.
ISNAD
Ergene, Lale T. - İmeryüz, Murat - Ekin, Cihad. “Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor”. Balkan Journal of Electrical and Computer Engineering 6/3 (01 Temmuz 2018): 153-158. https://doi.org/10.17694/bajece.426284.
JAMA
1.Ergene LT, İmeryüz M, Ekin C. Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor. Balkan Journal of Electrical and Computer Engineering. 2018;6:153–158.
MLA
Ergene, Lale T., vd. “Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor”. Balkan Journal of Electrical and Computer Engineering, c. 6, sy 3, Temmuz 2018, ss. 153-8, doi:10.17694/bajece.426284.
Vancouver
1.Lale T. Ergene, Murat İmeryüz, Cihad Ekin. Cross Saturation Inductance Analysis of a Permanent Magnet Synchronous Motor. Balkan Journal of Electrical and Computer Engineering. 01 Temmuz 2018;6(3):153-8. doi:10.17694/bajece.426284

Cited By

All articles published by BAJECE are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.Creative Commons Lisans