The electrospindle systems have been used in the maritime industry, they
have recently become operative in automation systems. Along with the widespread
use of harmonic generating machines and semi-conductor-based circuits in power
and control systems, known reactive power compensation methods have been
replaced by the use of filter-based compensation systems that consider harmonic
distortion. This study used a voltage signal generated by an electrospindle
generator with high harmonic distortion to obtain the amplitude time variation
of the fundamental component by using Discrete Wavelet Packet Transform (DWPT).
As a result of the analysis, it was observed that this method gives fast and
accurate results that can be also used in real-time applications.
electrospindle discrete wavelet packet transform(DWPT) harmonic analyses DC motor
Birincil Dil | İngilizce |
---|---|
Konular | Mühendislik |
Bölüm | Araştırma Makalesi |
Yazarlar | |
Yayımlanma Tarihi | 28 Ekim 2018 |
Yayımlandığı Sayı | Yıl 2018 Cilt: 6 Sayı: 4 |
All articles published by BAJECE are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.