Research Article

Determination of radon gas levels in the air in the faculty building (Bitlis)

Volume: 14 Number: 2 December 26, 2024
EN

Determination of radon gas levels in the air in the faculty building (Bitlis)

Abstract

Living things are exposed to internal and external natural radiation throughout their lives. Natural radiation consists mostly of cosmic rays and terrestrial radiation sources containing many radioisotopes. While uranium, thorium and potassium are the main radionuclides that constitute terrestrial natural radiation sources; radon is a radioactive gas that occurs naturally by the decay of uranium found in soil, rocks and water. People are mostly exposed to natural radiation due to building construction materials and indoor radon concentration. In this study, measurement of radon gas activity concentration levels in the air in Bitlis Eren University Faculty of Science and Letters building was made using an active radon measurement detector (AlphaGUARD). As a result of these measurements; The average radon activity concentration was determined as 41.13 Bq/m3. When the measurement results are compared with the limit values; It has been determined that there is no risk to health. Annual effective dose equivalent, AEDE, (average 0.889 mSv/y) and excess lifetime cancer risk, ELCR, (average 3.545) parameters were calculated using radon activity concentration values.

Keywords

Supporting Institution

There is no supporting institution.

Ethical Statement

The study is complied with research and publication ethics.

References

  1. A. Kurt, “Determination of Indoor Air Radon Concentrations in Primary Schools in Fatih District of Istanbul Province,” M.S. thesis, Science. Inst., İstanbul Univ., İstanbul, Türkiye, 2015.
  2. E. Fidan, “Adapazarı central winter radon measurement and analysis,” M.S. thesis, Science. Inst., İstanbul Technic Univ., İstanbul, Türkiye, 2009.
  3. A. Kaderoğlu, N. Kaya, V. E. Karaaslan and Y. S, Koç, “Ministry of National Education 12th Grade Physics Textbook”. Accessed: June, 08, 2023. [Online]. Available: https://ogmmateryal.eba.gov.tr/panel/upload/etkilesimli/ kitap/fenlisesifizik/12/unite4
  4. F. Cabi Değerli and F. Umaroğulları, “Radon in Buildings and Its Effects on Health”. Accessed: February, 04, 2023. [Online]. Available: https://www.yesilbinadergisi.com/yayin/264/binalarda-radon-ve-saglik-uzerindeki-etkileri_7919.html#.Y92G33ZBzIU
  5. WHO, Handbook on Indoor Radon: A Public Health Perspective. World Health Organization, Geneva, Switzerland, 2009.
  6. N. Elmastaş, “Geothermal spring in Bitlis province,” Eastern Geographical Review, vol.13, no. 19, pp. 89-104, 2011.
  7. M. C. Göncüoğlu and N. Turhan, “New age findings in Bitlis metamorphites,” Journal of Mineral Research and Exploration, vol. 95-96, pp. 1-5, 1981.
  8. A. Boray, “The Structure and Metamorphism of the Bitlis Area,” Türkiye Geoi. Founding Bulletin, vol. 95-96, pp. 1-5, 1981.

Details

Primary Language

English

Subjects

Nuclear Physics

Journal Section

Research Article

Publication Date

December 26, 2024

Submission Date

May 19, 2024

Acceptance Date

August 8, 2024

Published in Issue

Year 2024 Volume: 14 Number: 2

APA
Şahin Bal, S., & Dervişoğlu Koç, Y. (2024). Determination of radon gas levels in the air in the faculty building (Bitlis). Bitlis Eren University Journal of Science and Technology, 14(2), 103-118. https://doi.org/10.17678/beuscitech.1485248
AMA
1.Şahin Bal S, Dervişoğlu Koç Y. Determination of radon gas levels in the air in the faculty building (Bitlis). Bitlis Eren University Journal of Science and Technology. 2024;14(2):103-118. doi:10.17678/beuscitech.1485248
Chicago
Şahin Bal, Sultan, and Yonca Dervişoğlu Koç. 2024. “Determination of Radon Gas Levels in the Air in the Faculty Building (Bitlis)”. Bitlis Eren University Journal of Science and Technology 14 (2): 103-18. https://doi.org/10.17678/beuscitech.1485248.
EndNote
Şahin Bal S, Dervişoğlu Koç Y (December 1, 2024) Determination of radon gas levels in the air in the faculty building (Bitlis). Bitlis Eren University Journal of Science and Technology 14 2 103–118.
IEEE
[1]S. Şahin Bal and Y. Dervişoğlu Koç, “Determination of radon gas levels in the air in the faculty building (Bitlis)”, Bitlis Eren University Journal of Science and Technology, vol. 14, no. 2, pp. 103–118, Dec. 2024, doi: 10.17678/beuscitech.1485248.
ISNAD
Şahin Bal, Sultan - Dervişoğlu Koç, Yonca. “Determination of Radon Gas Levels in the Air in the Faculty Building (Bitlis)”. Bitlis Eren University Journal of Science and Technology 14/2 (December 1, 2024): 103-118. https://doi.org/10.17678/beuscitech.1485248.
JAMA
1.Şahin Bal S, Dervişoğlu Koç Y. Determination of radon gas levels in the air in the faculty building (Bitlis). Bitlis Eren University Journal of Science and Technology. 2024;14:103–118.
MLA
Şahin Bal, Sultan, and Yonca Dervişoğlu Koç. “Determination of Radon Gas Levels in the Air in the Faculty Building (Bitlis)”. Bitlis Eren University Journal of Science and Technology, vol. 14, no. 2, Dec. 2024, pp. 103-18, doi:10.17678/beuscitech.1485248.
Vancouver
1.Sultan Şahin Bal, Yonca Dervişoğlu Koç. Determination of radon gas levels in the air in the faculty building (Bitlis). Bitlis Eren University Journal of Science and Technology. 2024 Dec. 1;14(2):103-18. doi:10.17678/beuscitech.1485248

Cited By