Clinical Research

Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models

Volume: 49 Number: 2 August 28, 2025
EN

Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models

Abstract

Background: Advances in digital technologies have enabled multiple methods for measuring tooth size ratios; therefore, this study compared the reliability of manual, intraoral scanner, and model scanner techniques in determining anterior and overall Bolton ratios. Materials and Methods: Thirty-six female subjects aged 18–25 years were included. Plaster models were obtained using silicone impressions for manual measurements. Intraoral digital models were created with an intraoral scanner, and additional digital models were produced by scanning plaster casts with a model scanner. Anterior and overall Bolton ratios were measured on all three model types by two observers. Intra- and inter-observer reliability were assessed using intraclass correlation coefficients (ICCs). Bland–Altman analyses evaluated systematic and random errors, and repeated measures ANOVA tested differences between measurement methods. Results: Intra-observer reliability was highest for manual anterior measurements (ICC=0.914), followed by the model scanner (ICC=0.867), with intraoral scans showing lower consistency (ICC=0.826). Inter-observer agreement was lower across all methods, especially for intraoral scans. Bland–Altman analysis revealed the largest bias and widest limits of agreement in intraoral anterior measurements. Anterior Bolton ratios differed significantly between methods (p<0.001), with intraoral scans overestimating by 5–7 percentage points; overall Bolton ratios did not differ significantly (p=0.601). Conclusions: Manual and model scanner measurements provided comparable, reliable results for anterior Bolton analysis, whereas intraoral scanning showed greater variability and overestimation. For accurate assessment of anterior tooth size discrepancies, manual or model-based methods are preferable. Overall Bolton ratios can be reliably evaluated with any of the three methods.

Keywords

Supporting Institution

This study was supported by the Hacettepe University Scientific Research Projects Coordination Unit (Project number TAY-2023-20694).

Ethical Statement

The study protocol was approved by the Clinical Research Ethics Committee of Hacettepe University (Approval No: KA-22051).

References

  1. 1. Bolton WA. Disharmony in tooth size and its relation to the analysis and treatment of malocclusion. Angle Orthod 1958; 28: 113–130.
  2. 2. Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 2011; 14: 1–16.
  3. 3. Hassan WNW, Othman SA, Chan CS, Ahmad R, Ali SNA, Abd Rohim A. Assessing agreement in measurements of orthodontic study models: digital caliper on plaster models vs 3-dimensional software on models scanned by structured-light scanner. Am J Orthod Dentofacial Orthop 2016; 150: 886–895.
  4. 4. Lang FA, Lang NA, Vorloeper J, Niederau C, Craveiro RB, Knaup I et al. Validation of a digital, partly automated three-dimensional cast analysis for evaluation of orthodontic treatment assessment. Head Face Med 2025; 21: 1–14.
  5. 5. Sousa MV, Vasconcelos EC, Janson G, Garib D, Pinzan A. Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofacial Orthop 2012; 142: 269–273.
  6. 6. Quimby ML, Vig KW, Rashid RG, Firestone AR. The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 2004; 74: 298–303.
  7. 7. Kumar AA, Ananthakrishnan MG, Kumar S, Divakar G, Sekar S, Dharani S. Assessing the validity and reliability of tooth widths and Bolton ratios obtained from digital models and plaster models. J Pharm Bioall Sci 2022; 14(Suppl 1): 148–151.
  8. 8. San José V, Bellot-Arcís C, Tarazona B, Zamora N, Lagravère MO, Paredes-Gallardo V. Dental measurements and Bolton index reliability and accuracy obtained from 2D digital, 3D segmented CBCT, and 3D intraoral laser scanner. J Clin Exp Dent. 2017 ;9: 1466–1471.

Details

Primary Language

English

Subjects

Orthodontics and Dentofacial Orthopaedics

Journal Section

Clinical Research

Publication Date

August 28, 2025

Submission Date

June 30, 2025

Acceptance Date

July 22, 2025

Published in Issue

Year 2025 Volume: 49 Number: 2

APA
Ocak, I., Aksöz, G., Görücü Coşkuner, H., Atik, E., Akarsu Güven, B., Akcan, C. A., & Taner, T. (2025). Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models. Clinical Dentistry and Research, 49(2), 71-80. https://izlik.org/JA59TK29HC
AMA
1.Ocak I, Aksöz G, Görücü Coşkuner H, et al. Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models. Clin Dent Res. 2025;49(2):71-80. https://izlik.org/JA59TK29HC
Chicago
Ocak, Irmak, Gediz Aksöz, Hande Görücü Coşkuner, et al. 2025. “Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models”. Clinical Dentistry and Research 49 (2): 71-80. https://izlik.org/JA59TK29HC.
EndNote
Ocak I, Aksöz G, Görücü Coşkuner H, Atik E, Akarsu Güven B, Akcan CA, Taner T (August 1, 2025) Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models. Clinical Dentistry and Research 49 2 71–80.
IEEE
[1]I. Ocak et al., “Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models”, Clin Dent Res, vol. 49, no. 2, pp. 71–80, Aug. 2025, [Online]. Available: https://izlik.org/JA59TK29HC
ISNAD
Ocak, Irmak - Aksöz, Gediz - Görücü Coşkuner, Hande - Atik, Ezgi - Akarsu Güven, Bengisu - Akcan, Cenk Ahmet - Taner, Tülin. “Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models”. Clinical Dentistry and Research 49/2 (August 1, 2025): 71-80. https://izlik.org/JA59TK29HC.
JAMA
1.Ocak I, Aksöz G, Görücü Coşkuner H, Atik E, Akarsu Güven B, Akcan CA, Taner T. Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models. Clin Dent Res. 2025;49:71–80.
MLA
Ocak, Irmak, et al. “Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models”. Clinical Dentistry and Research, vol. 49, no. 2, Aug. 2025, pp. 71-80, https://izlik.org/JA59TK29HC.
Vancouver
1.Irmak Ocak, Gediz Aksöz, Hande Görücü Coşkuner, Ezgi Atik, Bengisu Akarsu Güven, Cenk Ahmet Akcan, Tülin Taner. Evaluation Of The Reliability And Reproducibility Of Bolton Ratios Using Intraoral Scanner, Model Scanner, And Plaster Models. Clin Dent Res [Internet]. 2025 Aug. 1;49(2):71-80. Available from: https://izlik.org/JA59TK29HC