Research Article

Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance

Volume: 40 Number: 1 March 22, 2019
Berna Saraçoğlu Kaya *, Ebru Sağ
EN TR

Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance

Abstract

In the second part of the two-part study, monodisperse and porous poly(vinyl acetate-co-divinylbenzene) [poly(VAc-co-DVB)] and poly(divinylbenzene) [poly(DVB)] column packing materials synthesized in the first part of the study were tested in Reverse Phase Chromatography (RPC) under different conditions. The investigation of column performances concluded that columns packed with poly(VAc-co-DVB) (2500 plate/m) and poly(DVB) (1500 plate/m), showed high and stable theoretical plate number and high peak resolution values compared to literature values. Protein recovery data in RPC column, poly(VAc-co-DVB) (93-99%), were determined as similar as quantitative values for all proteins. Reproducibility tests of analytes of poly(VAc-co-DVB) column were assessed "run to run" and "day to day" Relative Standard Deviation (RSD) values were determined under 2.8%.

Keywords

Monodisperse-Porous Particle,Column Packed Material,Reversed-Phase Chromatography (RPC),Protein Separation,Protein Separation

References

  1. [1]. Camlı, S.T., Şenel, S., Tuncel, A., Cibacron Blue F3G-A Attached Uniform and Macroporous Poly(styrene-divinlybenzene) Particles For Specific Albumin Adsorption. J. Biomater. Sci. Polym., 8 (1999) 875-889.
  2. [2]. Ellingsten, T., Aune, O., Ugelstad, J., Hagen, S., Mono-sized Stationary Phases for Chromatography, Journal of Chromatography A, 535 (1990) 147-161.
  3. [3]. Galia, M., Svec, F. , Fréchet, J.M.J., Monodisperse Polymer Beads as Packing Material for High-performance Liquid Chromatography. Effect of Divinylbenzene Content on the Porous and Chromatographic Properties of Poly(styrene-co-divinylbenzene) Beads Prepared in Presence of Linear Polystyrene as a Porogen, J. Polym. Sci., Polym. Chem., 32 (1994) 2169-2175
  4. [4]. Hossoya, K., Teramachi, M., Tanaka, N., Kobayashi, A., Kanda, T., Ohtsu, Y., Preparation Strategy for Uniformly Sized, Polymer-Beads HPLC Packing Materials Having Practically Acceptable Column Efficiency. 1. Copolymerization Technique, Anal. Chem., 73(24) (2001) 5852-5857
  5. [5]. Lewandowski, K., Svec, F., Frechet, J.M.J., Polar, A Novel Polar Seperation Medium For The Size Exclusion Chromatography of Small Molecules: Uniformly Sized, Porous Poly(vinylphenol-co-divinylbenzene) Beads, J. Liq. Chrom. & Rel. Technol., 20 (1997) 227-243
  6. [6]. Smigol, V., Svec, F., Frechet, J.M.J., 2-Dimensional High-Performance Liquid-Chromatography Using Monodisperse Polymer Beads Containing Segregated Chemistries Prepared By Pore-Size Specific Functionalization - Single-Column Combinations of Size Exclusion Or İon-Exchange With Reversed-Phase Chromatography, Analytical Chemistry, 66 (23) (1994) 4308- 4315
  7. [7]. Smigol, V., Svec, F., Frechet, J.M.J., High-Performance Liquid Chromatography of Complex mixtures Using Monodisperse Dual- Chemistry Polymer Beads Prepared by a Pore-Size-Specific Functionalization Process. A Single Column Combination of Hydrophobic Interaction and Reversed-Phase Chromatography, Analytical Chemistry, 66 (13) (1994) 2129-2138
  8. [8]. Unsal, E., Durdu, A., Elmas, B., Tuncel, M., Tuncel, A., A New Affinity-HPLC Packing For Protein Separation: Cibacron Blue Attached Uniform-Porous Poly(HEMA-co-EDM) Beads, Analytical and Bioanalytical Chemistry, 383 (2005) 930-937
  9. [9]. Unsal, E., Irmak, T., Durusoy, E., Tuncel, M., Tuncel, A., Monodisperse porous particles with polyionic ligands for ion exchange separation of proteins, Analytical Chimica Acta, 570 (2006) 240-248 [10]. Ettre, L.S., Chromatography: the Separation Technique of the 20th Century. Chromatographia, 51 (1/2) (2000) 7-17
  10. [11]. Engelhardt, H., One century of liquid chromatography from Tswett’s columns to modern high speed and high performance separations, Journal of Chromatography B, 800 (1-2) (2004) 3-6
APA
Saraçoğlu Kaya, B., & Sağ, E. (2019). Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance. Cumhuriyet Science Journal, 40(1), 213-220. https://doi.org/10.17776/csj.364625
AMA
1.Saraçoğlu Kaya B, Sağ E. Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance. CSJ. 2019;40(1):213-220. doi:10.17776/csj.364625
Chicago
Saraçoğlu Kaya, Berna, and Ebru Sağ. 2019. “Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance”. Cumhuriyet Science Journal 40 (1): 213-20. https://doi.org/10.17776/csj.364625.
EndNote
Saraçoğlu Kaya B, Sağ E (March 1, 2019) Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance. Cumhuriyet Science Journal 40 1 213–220.
IEEE
[1]B. Saraçoğlu Kaya and E. Sağ, “Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance”, CSJ, vol. 40, no. 1, pp. 213–220, Mar. 2019, doi: 10.17776/csj.364625.
ISNAD
Saraçoğlu Kaya, Berna - Sağ, Ebru. “Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance”. Cumhuriyet Science Journal 40/1 (March 1, 2019): 213-220. https://doi.org/10.17776/csj.364625.
JAMA
1.Saraçoğlu Kaya B, Sağ E. Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance. CSJ. 2019;40:213–220.
MLA
Saraçoğlu Kaya, Berna, and Ebru Sağ. “Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance”. Cumhuriyet Science Journal, vol. 40, no. 1, Mar. 2019, pp. 213-20, doi:10.17776/csj.364625.
Vancouver
1.Berna Saraçoğlu Kaya, Ebru Sağ. Design of Reversed-Phase Chromatography Column Packing Material for Protein Separation: Part 2- Chromatographic Performance. CSJ. 2019 Mar. 1;40(1):213-20. doi:10.17776/csj.364625