                <article-meta>
                                        <article-id/>
                                                                                                                                                                                            <title-group>
                                                                                                                        <trans-title-group xml:lang="en">
                                    <trans-title>WIRELESS SURFACE ELECTROMYOGRAPHY DEVICE DESIGN FOR LUMBAR DISC HERNIATED PATIENTS</trans-title>
                                </trans-title-group>
                                                                                                                                                                                                <article-title>LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI</article-title>
                                                                                                    </title-group>
            
                                                    <contrib-group content-type="authors">
                                                                        <contrib contrib-type="author">
                                                                <name>
                                    <surname>Çakar</surname>
                                    <given-names>Halil İbrahim</given-names>
                                </name>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                <name>
                                    <surname>Kara</surname>
                                    <given-names>Sadık</given-names>
                                </name>
                                                            </contrib>
                                                    <contrib contrib-type="author">
                                                                <name>
                                    <surname>Toker</surname>
                                    <given-names>Onur</given-names>
                                </name>
                                                            </contrib>
                                                                                </contrib-group>
                        
                                        <pub-date pub-type="pub" iso-8601-date="20150501">
                    <day>05</day>
                    <month>01</month>
                    <year>2015</year>
                </pub-date>
                                        <volume>17</volume>
                                        <issue>50</issue>
                                        <fpage>84</fpage>
                                        <lpage>94</lpage>
                        
                        <history>
                                    <date date-type="received" iso-8601-date="20150501">
                        <day>05</day>
                        <month>01</month>
                        <year>2015</year>
                    </date>
                                            </history>
                                        <permissions>
                    <copyright-statement>Copyright © 1999, Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi</copyright-statement>
                    <copyright-year>1999</copyright-year>
                    <copyright-holder>Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi</copyright-holder>
                </permissions>
            
                                                                                                <trans-abstract xml:lang="en">
                            <p>A portable and wireless surface electromyography device was developed for tracking the regional muscular activities of lumbar disc herniated patients. Previous studies showed that there is relation between paraspinal muscular activities and lumbar disc herniation. These studies encouraged us to develop a novel wireless surface electromyography device to follow muscular activities of lumbar disc herniated patients. Using such kind of wireless system in lumbar disc herniation studies leads to follow muscular activities practically. The overall system would lead to make diagnosis of lumbar disc herniation with a novel approach. The developed system consists of four major stages; amplification, filtering, A/D conversion, and the wireless communication stages. Bluetooth technology is chosen for communication between the proposed device and the computer. The designed device can be fully controlled within MATLAB software, and measured data can be directly streamed to computer environment. As a demonstration of the developed system, we also did certain signal processing operations in MATLAB by using measured surface electromyography signals</p></trans-abstract>
                                                                                                                                    <abstract><p>Bel fıtıklı hastaların bölgesel kas faaliyetlerinin takibi amacıyla portatif ve kablosuz bir yüzey elektromiyografi cihazı geliştirilmiştir. Önceki çalışmalar paraspinal kas aktiviteleri ile bel fıtığı arasında ilişki olduğunu göstermektedir. Bu çalışmalar bel fıtıklı hastaların kas faaliyetlerini takip amacıyla yeni bir kablosuz yüzey elektromiyografi cihazı yapmaya teşvik etmiştir. Böyle kablosuz cihazın kullanımı bel fıtıklı hastaların kas akitivitelerini daha kolay takibini sağlayacaktır. Genel olarak sistem yeni bir yaklaşım ile bel fıtığı teşhisinin yapılabilmesinin önünü açabilecektir.Geliştirilen sistem kuvvetlendirme, filtreleme, analog-dijital dönüştürme ve kablosuz haberleşme olmak üzere dört ana kısımdan oluşmaktadır. Elde edilen cihaz ile bilgisayar arasındaki haberleşme için Bluetooth teknolojisi kullanılmıştır. Cihaz MATLAB yazılımı üzerinden kontrol edilebilmektedir ve doğrudan bilgisayar ortamına aktarılmaktadır. Geliştirilen sistem ile elde edilen yüzey elektromiyografi sinyalleri üzerinde MATLAB programıyla sinyal işleme de yapılmıştır</p></abstract>
                                                            
            
                                                                                        <kwd-group>
                                                    <kwd>Yüzey elektromiyografi</kwd>
                                                    <kwd>   Lomber disk hernisi</kwd>
                                                    <kwd>   Gömülü biyomedikal sistemler</kwd>
                                            </kwd-group>
                            
                                                <kwd-group xml:lang="en">
                                                    <kwd>Surface electromyography</kwd>
                                                    <kwd>   Lumbar disc herniation</kwd>
                                                    <kwd>   Embedded biomedical systems</kwd>
                                            </kwd-group>
                                                                                                                                        </article-meta>
    </front>
    <back>
                            <ref-list>
                                    <ref id="ref1">
                        <label>1</label>
                        <mixed-citation publication-type="journal">Geisser ME. Surface Electromyography and Low Back Pain, Biofeedback, Vol. 35, No. 1, 2007, pp.13-16. [2] Jordan J, Konstantinou K, O’Dowd</mixed-citation>
                    </ref>
                                    <ref id="ref2">
                        <label>2</label>
                        <mixed-citation publication-type="journal">http://clinicalevidence.bmj.com/ceweb/conditions/msd/1118/1118_background.jsp#REF4] 2009. J. Herniated Lumbar Disc,</mixed-citation>
                    </ref>
                                    <ref id="ref3">
                        <label>3</label>
                        <mixed-citation publication-type="journal">Skinner H. Current Diagnosis &amp; Treatment in Orthopedics, New York: Appleton &amp; Lange, 3rd Edition, 2003.</mixed-citation>
                    </ref>
                                    <ref id="ref4">
                        <label>4</label>
                        <mixed-citation publication-type="journal">Çevikcan B, Kara S. Bel Fıtığı Hastalığı Bulunan Bireylerin Bel Ve Karın Kası Fonksiyonlarının Elektromiyografik Analizi, Elektrik, Elektronik, Bilgisayar, Biyomedikal Mühendisliği XII.Ulusal Kongresi ve Fuarı, Eskişehir, 2007.</mixed-citation>
                    </ref>
                                    <ref id="ref5">
                        <label>5</label>
                        <mixed-citation publication-type="journal">Çakar Hİ, Kara S, Toker O. Bel Fıtığı Hastalığı Analizi için Portatif Elektromyiografi Cihazı Tasarımı, Biyomut 2010-15th National Meeting of Biomedical Engineering, Antalya, 2010.</mixed-citation>
                    </ref>
                                    <ref id="ref6">
                        <label>6</label>
                        <mixed-citation publication-type="journal">Çakar Hİ, Kara S, Toker O. Design of a Portable Electromyography Device for Back Herniated Patients, Biodevices 2010- 3rd International Conference on Biomedical Electronics and Devices, Valencia, 2010.</mixed-citation>
                    </ref>
                                    <ref id="ref7">
                        <label>7</label>
                        <mixed-citation publication-type="journal">De Luca CJ. Use of the Surface EMG Signal for Performance Evaluation of Back Muscles, Muscle&amp;Nerve, Vol. 16, No. 2, 1993, pp.210-216.</mixed-citation>
                    </ref>
                                    <ref id="ref8">
                        <label>8</label>
                        <mixed-citation publication-type="journal">Haig AJ, Weismann, G, Haugh LD, Pope M, Grobler LJ. Prospective Evidence for Change in Paraspinal Muscle Activity after Herniated Nucleus Pulposus, Spine, Vol. 18, No. 7, 1993, pp.926-929.</mixed-citation>
                    </ref>
                                    <ref id="ref9">
                        <label>9</label>
                        <mixed-citation publication-type="journal">Jalovaara P, Niinimäki T, Vanharanta H. Pocket-Size, Portable Surface EMG Device in the Differentiation of Low Back Pain Patients, European Spine Journal, Vol. 4, No. 4, 1995, pp.210-212.</mixed-citation>
                    </ref>
                                    <ref id="ref10">
                        <label>10</label>
                        <mixed-citation publication-type="journal">Ambroz C, Scott A, Ambroz A, Talbott EO. Chronic Low Back Pain Assessment Using Surface Electromyography”, Journal of Occupational and Environmental Medicine, Vol. 42, No. 6, 2000, pp.660-669. [11]</mixed-citation>
                    </ref>
                                    <ref id="ref11">
                        <label>11</label>
                        <mixed-citation publication-type="journal">Çakar Hİ, Kara S, Toker O. A Wireless Surface Electromyography System Design for 
Lumbar Disc Herniated Patients, Memea 2011- IEEE International Symposium on</mixed-citation>
                    </ref>
                                    <ref id="ref12">
                        <label>12</label>
                        <mixed-citation publication-type="journal">Medical Measurements and Applications, Bari, 2010. [12] Basmajian JV, De Luca CJ. Muscles Alive: Their Functions Revealed by</mixed-citation>
                    </ref>
                                    <ref id="ref13">
                        <label>13</label>
                        <mixed-citation publication-type="journal">Electromyography, Baltimore: Williams &amp; Wilkins, 3rd Edition, 1974. [13] Analog Devices, AD620: Low Drift, Low Power Instrumentation Amplifier with Set</mixed-citation>
                    </ref>
                                    <ref id="ref14">
                        <label>14</label>
                        <mixed-citation publication-type="journal">Gains of 1 to 10000, [http://www.analog.com], 2004. [14] Analog Devices, AD620: Low Drift, Low Power Instrumentation Amplifier with Set</mixed-citation>
                    </ref>
                                    <ref id="ref15">
                        <label>15</label>
                        <mixed-citation publication-type="journal">Gains of 1 to 10000, [http://www.analog.com], 2004. [15] Çakar Hİ. Design of a Portable Surface Electromyography (SEMG) Device for</mixed-citation>
                    </ref>
                                    <ref id="ref16">
                        <label>16</label>
                        <mixed-citation publication-type="journal">Collection of SEMG Signals from Back Herniated Patients”, MSc Thesis, İstanbul: Fatih</mixed-citation>
                    </ref>
                                    <ref id="ref17">
                        <label>17</label>
                        <mixed-citation publication-type="journal">University, 2010. [16] Spinelli EM, Pallás-Areny R, Mayosky MA. AC-Coupled Front-End for Biopotential</mixed-citation>
                    </ref>
                                    <ref id="ref18">
                        <label>18</label>
                        <mixed-citation publication-type="journal">Texas Instruments, ADS7813-Low Power, Serial 16-Bit Sampling Analog-to-Digital Converter, [http://www.ti.com], 2005.</mixed-citation>
                    </ref>
                                    <ref id="ref19">
                        <label>19</label>
                        <mixed-citation publication-type="journal">Bluegiga Technologies, WT12 Datasheet Version 2.8, [http://www.bluegiga.com/], 2009.</mixed-citation>
                    </ref>
                                    <ref id="ref20">
                        <label>20</label>
                        <mixed-citation publication-type="journal">MICROCHIP, PIC18F452-28/40 pin High Performance, Enhanced FLASH Microcontrollers with 10-Bit A/D, [http://www.microchip.com], 2006.</mixed-citation>
                    </ref>
                                    <ref id="ref21">
                        <label>21</label>
                        <mixed-citation publication-type="journal">Welch PD. “The Use of Fast Fourier Transform for the Estimation of Power Spectra: A Method Based on Time Averaging Over Short, Modified Periodograms”, IEEE Transactions on Audio and Electroacoustics, Vol. AU-15, 1967, pp.70-73.</mixed-citation>
                    </ref>
                            </ref-list>
                    </back>
    </article>