EN
Electric Pulp Testing with Examination Gloves
Abstract
Aim The objective of this study is to determine differences between EPT results for the same teeth with the operator’s hands being gloved and ungloved.
Material and method Electric pulp tests were conducted for the same teeth with the operator’s hands being gloved and ungloved. Twenty male and twenty female patients were included in this study.
Results Statistically significant differences between EPT results for the same teeth with the operator’s hands being gloved and ungloved were observed.
Conclusion In conclusion, the clinician should not use the EPT while wearing examination gloves.
Keywords
References
- Chen E, Abbott P V. Dental Pulp Testing: A Review. Int J Dent. 2009;2009:1-12. doi:10.1155/2009/365785
- Jafarzadeh H, Abbott P V. Review of pulp sensibility tests. Part II: Electric pulp tests and test cavities. Int Endod J. 2010;43(11):945-958. doi:10.1111/j.1365-2591.2010.01760.x
- Lin J, Chandler NP. Electric pulp testing: A review. Int Endod J. 2008;41(5):365-374. doi:10.1111/j.1365-2591.2008.01375.x
- Samuel S, Thomas A, Singh N. A comparative study of pulse oximetry with the conventional pulp testing methods to assess vitality in immature and mature permanent maxillary incisors. CHRISMED J Heal Res. 2014;1(4):235. doi:10.4103/2348-3334.142985
- Sharma A, Madan M, Shahi P, Sood P, Shahi N. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent. 2015;8(2):94-98. doi:10.5005/jp-journals-10005-1291
Details
Primary Language
English
Subjects
Oral and Maxillofacial Radiology
Journal Section
Research Article
Publication Date
December 20, 2023
Submission Date
October 13, 2023
Acceptance Date
October 20, 2023
Published in Issue
Year 2023 Volume: 1 Number: 3
APA
Zengin, U., Tufan Yücesoy, M., & Moghbel, M. (2023). Electric Pulp Testing with Examination Gloves. Eurasian Dental Research, 1(3), 65-67. https://izlik.org/JA37ER59ZC
AMA
1.Zengin U, Tufan Yücesoy M, Moghbel M. Electric Pulp Testing with Examination Gloves. EDR. 2023;1(3):65-67. https://izlik.org/JA37ER59ZC
Chicago
Zengin, Umut, Melek Tufan Yücesoy, and Mehran Moghbel. 2023. “Electric Pulp Testing With Examination Gloves”. Eurasian Dental Research 1 (3): 65-67. https://izlik.org/JA37ER59ZC.
EndNote
Zengin U, Tufan Yücesoy M, Moghbel M (December 1, 2023) Electric Pulp Testing with Examination Gloves. Eurasian Dental Research 1 3 65–67.
IEEE
[1]U. Zengin, M. Tufan Yücesoy, and M. Moghbel, “Electric Pulp Testing with Examination Gloves”, EDR, vol. 1, no. 3, pp. 65–67, Dec. 2023, [Online]. Available: https://izlik.org/JA37ER59ZC
ISNAD
Zengin, Umut - Tufan Yücesoy, Melek - Moghbel, Mehran. “Electric Pulp Testing With Examination Gloves”. Eurasian Dental Research 1/3 (December 1, 2023): 65-67. https://izlik.org/JA37ER59ZC.
JAMA
1.Zengin U, Tufan Yücesoy M, Moghbel M. Electric Pulp Testing with Examination Gloves. EDR. 2023;1:65–67.
MLA
Zengin, Umut, et al. “Electric Pulp Testing With Examination Gloves”. Eurasian Dental Research, vol. 1, no. 3, Dec. 2023, pp. 65-67, https://izlik.org/JA37ER59ZC.
Vancouver
1.Umut Zengin, Melek Tufan Yücesoy, Mehran Moghbel. Electric Pulp Testing with Examination Gloves. EDR [Internet]. 2023 Dec. 1;1(3):65-7. Available from: https://izlik.org/JA37ER59ZC