Research Article

Electric Pulp Testing with Examination Gloves

Volume: 1 Number: 3 December 20, 2023
EN

Electric Pulp Testing with Examination Gloves

Abstract

Aim The objective of this study is to determine differences between EPT results for the same teeth with the operator’s hands being gloved and ungloved. Material and method Electric pulp tests were conducted for the same teeth with the operator’s hands being gloved and ungloved. Twenty male and twenty female patients were included in this study. Results Statistically significant differences between EPT results for the same teeth with the operator’s hands being gloved and ungloved were observed. Conclusion In conclusion, the clinician should not use the EPT while wearing examination gloves.

Keywords

References

  1. Chen E, Abbott P V. Dental Pulp Testing: A Review. Int J Dent. 2009;2009:1-12. doi:10.1155/2009/365785
  2. Jafarzadeh H, Abbott P V. Review of pulp sensibility tests. Part II: Electric pulp tests and test cavities. Int Endod J. 2010;43(11):945-958. doi:10.1111/j.1365-2591.2010.01760.x
  3. Lin J, Chandler NP. Electric pulp testing: A review. Int Endod J. 2008;41(5):365-374. doi:10.1111/j.1365-2591.2008.01375.x
  4. Samuel S, Thomas A, Singh N. A comparative study of pulse oximetry with the conventional pulp testing methods to assess vitality in immature and mature permanent maxillary incisors. CHRISMED J Heal Res. 2014;1(4):235. doi:10.4103/2348-3334.142985
  5. Sharma A, Madan M, Shahi P, Sood P, Shahi N. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent. 2015;8(2):94-98. doi:10.5005/jp-journals-10005-1291

Details

Primary Language

English

Subjects

Oral and Maxillofacial Radiology

Journal Section

Research Article

Publication Date

December 20, 2023

Submission Date

October 13, 2023

Acceptance Date

October 20, 2023

Published in Issue

Year 2023 Volume: 1 Number: 3

APA
Zengin, U., Tufan Yücesoy, M., & Moghbel, M. (2023). Electric Pulp Testing with Examination Gloves. Eurasian Dental Research, 1(3), 65-67. https://izlik.org/JA37ER59ZC
AMA
1.Zengin U, Tufan Yücesoy M, Moghbel M. Electric Pulp Testing with Examination Gloves. EDR. 2023;1(3):65-67. https://izlik.org/JA37ER59ZC
Chicago
Zengin, Umut, Melek Tufan Yücesoy, and Mehran Moghbel. 2023. “Electric Pulp Testing With Examination Gloves”. Eurasian Dental Research 1 (3): 65-67. https://izlik.org/JA37ER59ZC.
EndNote
Zengin U, Tufan Yücesoy M, Moghbel M (December 1, 2023) Electric Pulp Testing with Examination Gloves. Eurasian Dental Research 1 3 65–67.
IEEE
[1]U. Zengin, M. Tufan Yücesoy, and M. Moghbel, “Electric Pulp Testing with Examination Gloves”, EDR, vol. 1, no. 3, pp. 65–67, Dec. 2023, [Online]. Available: https://izlik.org/JA37ER59ZC
ISNAD
Zengin, Umut - Tufan Yücesoy, Melek - Moghbel, Mehran. “Electric Pulp Testing With Examination Gloves”. Eurasian Dental Research 1/3 (December 1, 2023): 65-67. https://izlik.org/JA37ER59ZC.
JAMA
1.Zengin U, Tufan Yücesoy M, Moghbel M. Electric Pulp Testing with Examination Gloves. EDR. 2023;1:65–67.
MLA
Zengin, Umut, et al. “Electric Pulp Testing With Examination Gloves”. Eurasian Dental Research, vol. 1, no. 3, Dec. 2023, pp. 65-67, https://izlik.org/JA37ER59ZC.
Vancouver
1.Umut Zengin, Melek Tufan Yücesoy, Mehran Moghbel. Electric Pulp Testing with Examination Gloves. EDR [Internet]. 2023 Dec. 1;1(3):65-7. Available from: https://izlik.org/JA37ER59ZC