Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2023, Cilt: 1 Sayı: 3, 65 - 67, 20.12.2023

Öz

Kaynakça

  • Chen E, Abbott P V. Dental Pulp Testing: A Review. Int J Dent. 2009;2009:1-12. doi:10.1155/2009/365785
  • Jafarzadeh H, Abbott P V. Review of pulp sensibility tests. Part II: Electric pulp tests and test cavities. Int Endod J. 2010;43(11):945-958. doi:10.1111/j.1365-2591.2010.01760.x
  • Lin J, Chandler NP. Electric pulp testing: A review. Int Endod J. 2008;41(5):365-374. doi:10.1111/j.1365-2591.2008.01375.x
  • Samuel S, Thomas A, Singh N. A comparative study of pulse oximetry with the conventional pulp testing methods to assess vitality in immature and mature permanent maxillary incisors. CHRISMED J Heal Res. 2014;1(4):235. doi:10.4103/2348-3334.142985
  • Sharma A, Madan M, Shahi P, Sood P, Shahi N. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent. 2015;8(2):94-98. doi:10.5005/jp-journals-10005-1291

Electric Pulp Testing with Examination Gloves

Yıl 2023, Cilt: 1 Sayı: 3, 65 - 67, 20.12.2023

Öz

Aim The objective of this study is to determine differences between EPT results for the same teeth with the operator’s hands being gloved and ungloved.
Material and method Electric pulp tests were conducted for the same teeth with the operator’s hands being gloved and ungloved. Twenty male and twenty female patients were included in this study.
Results Statistically significant differences between EPT results for the same teeth with the operator’s hands being gloved and ungloved were observed.
Conclusion In conclusion, the clinician should not use the EPT while wearing examination gloves.

Kaynakça

  • Chen E, Abbott P V. Dental Pulp Testing: A Review. Int J Dent. 2009;2009:1-12. doi:10.1155/2009/365785
  • Jafarzadeh H, Abbott P V. Review of pulp sensibility tests. Part II: Electric pulp tests and test cavities. Int Endod J. 2010;43(11):945-958. doi:10.1111/j.1365-2591.2010.01760.x
  • Lin J, Chandler NP. Electric pulp testing: A review. Int Endod J. 2008;41(5):365-374. doi:10.1111/j.1365-2591.2008.01375.x
  • Samuel S, Thomas A, Singh N. A comparative study of pulse oximetry with the conventional pulp testing methods to assess vitality in immature and mature permanent maxillary incisors. CHRISMED J Heal Res. 2014;1(4):235. doi:10.4103/2348-3334.142985
  • Sharma A, Madan M, Shahi P, Sood P, Shahi N. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent. 2015;8(2):94-98. doi:10.5005/jp-journals-10005-1291
Toplam 5 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Ağız, Diş ve Çene Radyolojisi
Bölüm Research Articles
Yazarlar

Umut Zengin 0009-0004-1703-1900

Melek Tufan Yücesoy 0009-0002-3603-9989

Mehran Moghbel 0000-0002-4502-8950

Yayımlanma Tarihi 20 Aralık 2023
Gönderilme Tarihi 13 Ekim 2023
Kabul Tarihi 20 Ekim 2023
Yayımlandığı Sayı Yıl 2023 Cilt: 1 Sayı: 3

Kaynak Göster

Vancouver Zengin U, Tufan Yücesoy M, Moghbel M. Electric Pulp Testing with Examination Gloves. EDR. 2023;1(3):65-7.