Research Article

Finite element simulation of femoral stems lightweighted with re-entrant honeycomb lattice structure

Volume: 7 Number: 3 September 20, 2023
EN

Finite element simulation of femoral stems lightweighted with re-entrant honeycomb lattice structure

Abstract

Artificial hip joints are used to replace damaged or diseased natural joints. When the stress that is typically applied to the bone changes because the implant and bone are different in stiffness, a phenomenon known as stress shielding occurs. Stress shielding can lead to bone weakening through reduced density and aseptic loosening in the long term. Studies are ongoing to overcome this phenomenon through geometric design, the use of materials with a low modulus of elasticity, or latticed implants. In this study, the effect of lightening the hip prosthesis with lattice structures on stress shielding is investigated using finite element simulation. The femoral stem of a solid hip prosthesis was lightweighted, with a re-entrant honeycomb auxetic cellular lattice structure, and structural analysis was performed. Two different lattice orientations were used, and it was observed that the stress distribution was more homogeneous in both orientations. In these femoral stems, which can be easily produced using additive manufacturing methods, a volume reduction of up to 16% was achieved. The stress transmitted to the bone increased by more than 36%, depending on the orientation, which is a promising result for reducing the stress shield effect.

Keywords

References

  1. [1] Guo, L., Ataollah Naghavi, S., Wang, Z., Nath Varma, S., Han, Z., Yao, Z., et al., (2022). On the design evolution of hip implants: A review. Materials & Design. 216: 110552 1-19. doi: 10.1016/j.matdes.2022.110552.
  2. [2] Bilhère-Dieuzeide, M., Chaves-Jacob, J., Buhon, E., Biguet-Mermet, G., Linares, J.-M., (2022). Material Removal of Hip Stem Prosthesis Using Bio-Inspiration from Trabecular Bone. Procedia CIRP. 110: 265–270. doi: 10.1016/j.procir.2022.06.048.
  3. [3] Tyagi, S.A., M, M., (2023). Additive manufacturing of titanium-based lattice structures for medical applications – A review. Bioprinting. 30: e00267. doi: 10.1016/j.bprint.2023.e00267.
  4. [4] Jetté, B., Brailovski, V., Dumas, M., Simoneau, C., Terriault, P., (2018). Femoral stem incorporating a diamond cubic lattice structure: Design, manufacture and testing. Journal of the Mechanical Behavior of Biomedical Materials. 77: 58–72. doi: 10.1016/j.jmbbm.2017.08.034.
  5. [5] Seharing, A., Azman, A.H., Abdullah, S., (2020). A review on integration of lightweight gradient lattice structures in additive manufacturing parts. Advances in Mechanical Engineering. 12(6): 1–21. doi: 10.1177/1687814020916951.
  6. [6] Xiao, R., Feng, X., Fan, R., Chen, S., Song, J., Gao, L., et al., (2020). 3D printing of titanium-coated gradient composite lattices for lightweight mandibular prosthesis. Composites Part B: Engineering. 193: 108057 1-10. doi: 10.1016/j.compositesb.2020.108057.
  7. [7] Zhang, X.Z., Leary, M., Tang, H.P., Song, T., Qian, M., (2018). Selective electron beam manufactured Ti-6Al-4V lattice structures for orthopedic implant applications: Current status and outstanding challenges. Current Opinion in Solid State and Materials Science. 22(3): 75–99. doi: 10.1016/j.cossms.2018.05.002.
  8. [8] Aufa, A.N., Hassan, M.Z., Ismail, Z., (2022). Recent advances in Ti-6Al-4V additively manufactured by selective laser melting for biomedical implants: Prospect development. Journal of Alloys and Compounds. 896: 163072. doi: 10.1016/j.jallcom.2021.163072.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

September 20, 2023

Submission Date

April 25, 2023

Acceptance Date

June 28, 2023

Published in Issue

Year 2023 Volume: 7 Number: 3

APA
Bayrak, Ö. (2023). Finite element simulation of femoral stems lightweighted with re-entrant honeycomb lattice structure. European Mechanical Science, 7(3), 128-137. https://doi.org/10.26701/ems.1287321

Cited By


Dergi TR Dizin'de Taranmaktadır.

Flag Counter