Research Article

Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption

Volume: 59 Number: 2 May 21, 2025
EN

Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption

Abstract

Purpose: The aim of this study is to compare the accuracy of root resorption volume measurements among three cone-beam computed tomography (CBCT) devices using various imaging parameters. Materials and Methods: A total of 42 external root resorption (ERR) defects were mechanically created on the buccal and palatinal surfaces of the roots of seven extracted human teeth. Volume measurements of the defects were performed using three CBCT devices and six different imaging protocols. CBCT measurements were then compared with those calculated from micro-computed tomography (micro-CT) images. Results: The mean absolute error values indicated that the rate of measurement accuracies from best to worst was obtained with KaVo 3D eXam (0.125 mm voxel, 0.2 mm voxel, respectively), Orthophos XG 3D (0.1 mm voxel, 0.16 mm voxel, respectively), and Rainbow CT (0.2 mm voxel, 0.3 mm voxel, respectively). No statistically significant difference was found between any of the CBCT measurements in comparison to the micro-CT evaluations. Conclusion: Although external root resorption is a small object to evaluate using CBCT, larger voxel sizes (e.g., 0.3 mm) of CBCT systems can be employed during scanning without compromising image quality.

Keywords

Thanks

I would like to thank my esteemed professor Prof Dr Pelin Güneri for reviewing the article and making suggestions

References

  1. Kamburoğlu K, Kurşun S, Yüksel S, Oztaş B. Observer ability to detect ex vivo simulated internal or external cervical root resorption. J Endod 2011;37:168-75. google scholar
  2. Neves FS, Vasconcelos TV, Vaz SL, Freitas DQ, Haiter-Neto F. Evaluation of reconstructed images with different voxel sizes of acquisition in the diagnosis of simulated external root resorption using cone beam computed tomography. Int Endod J 2012;45:234-9. google scholar
  3. Creanga AG, Geha H, Sankar V, Teixeira FB, McMahan CA, Noujeim M. Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption. Imaging Sci Dent 2015;45:153-8. google scholar
  4. Andreasen JO. Luxation of permanent teeth due to trauma. A clinical and radiographic follow-up study of 189 injured teeth. Scand J Dent Res 1970; 78: 273-86. google scholar
  5. Heithersay GS. Invasive cervical resorption. Endod Topics 2004;7:73-92. google scholar
  6. Makkes PC, Thoden van Velzen SK. Cervical external root resorption. J Dent 1975;3:217-22. google scholar
  7. Alqerban A, Jacobs R, Souza PC, Willems G. In-vitro comparison of 2 cone-beam computed tomography systems and panoramic imaging for detecting simulated canine impaction-induced external root resorption in maxillary lateral incisors. Am J Orthod Dentofacial Orthop 2009; 136:764-5. google scholar
  8. Patel S, Foschi F, Condon R, Pimentel T, Bhuva B. External cervical resorption: part 2 - management. Int Endod J 2018;51:1224-38. google scholar

Details

Primary Language

English

Subjects

Dentistry (Other)

Journal Section

Research Article

Publication Date

May 21, 2025

Submission Date

February 4, 2023

Acceptance Date

October 26, 2023

Published in Issue

Year 2025 Volume: 59 Number: 2

APA
Öner Talmaç, A. G., & Koç, A. (2025). Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption. European Oral Research, 59(2), 77-83. https://doi.org/10.26650/eor.20241247459
AMA
1.Öner Talmaç AG, Koç A. Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption. EOR. 2025;59(2):77-83. doi:10.26650/eor.20241247459
Chicago
Öner Talmaç, Ayşe Gül, and Alaettin Koç. 2025. “Comparison of the Accuracy of Different Cone Beam Computed Tomography Systems in Measuring the Volume of External Root Resorption”. European Oral Research 59 (2): 77-83. https://doi.org/10.26650/eor.20241247459.
EndNote
Öner Talmaç AG, Koç A (May 1, 2025) Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption. European Oral Research 59 2 77–83.
IEEE
[1]A. G. Öner Talmaç and A. Koç, “Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption”, EOR, vol. 59, no. 2, pp. 77–83, May 2025, doi: 10.26650/eor.20241247459.
ISNAD
Öner Talmaç, Ayşe Gül - Koç, Alaettin. “Comparison of the Accuracy of Different Cone Beam Computed Tomography Systems in Measuring the Volume of External Root Resorption”. European Oral Research 59/2 (May 1, 2025): 77-83. https://doi.org/10.26650/eor.20241247459.
JAMA
1.Öner Talmaç AG, Koç A. Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption. EOR. 2025;59:77–83.
MLA
Öner Talmaç, Ayşe Gül, and Alaettin Koç. “Comparison of the Accuracy of Different Cone Beam Computed Tomography Systems in Measuring the Volume of External Root Resorption”. European Oral Research, vol. 59, no. 2, May 2025, pp. 77-83, doi:10.26650/eor.20241247459.
Vancouver
1.Ayşe Gül Öner Talmaç, Alaettin Koç. Comparison of the accuracy of different cone beam computed tomography systems in measuring the volume of external root resorption. EOR. 2025 May 1;59(2):77-83. doi:10.26650/eor.20241247459