Research Article

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants

Volume: 55 Number: 2 June 28, 2021
  • Rohini Rajendran
  • N. Gopi Chander *
  • Kuttae Vishwanathan Anitha
  • Balasubramanian Muthukumar
EN

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants

Abstract

Purpose The present study compared the dimensional accuracy of vinyl polyether silicone (VPES) and polyvinyl siloxane (PVS) impression materials used for non-splinted (NS) and splinted (S) direct open-tray impression techniques for multiple implants inserted in simulated edentulous mandibles. Materials and Methods A mandibular stainless steel model with eight internal connections for implant analogs was fabricated to simulate a clinical scenario. The acrylic resin splinted and non-splinted direct impressions were obtained for both VPES and PVS materials. Seventy-two cast samples were divided into four groups based on the impression techniques and materials used. The dimensional accuracies of the casts were measured in three different axes using a computerized coordinate measuring machine (CMM), and were statistically compared. Results The differences in the distortion values between the VPES and PVS impression materials were not statistically significant. Similarly, the differences between the splinted and non-splinted groups among the VPES and PVS materials were not statistically significant. Conclusion The casts fabricated from VPS or PVS impression materials provide similar dimensional accuracy regardless of the implant splinting method.

Keywords

References

  1. 1. Buser D, Janner SF, Wittneben JG, Bragger U, Ramseier CA, Salvi GE. 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res 2012;14:839-51. [CrossRef] google scholar
  2. 2. Ravald N, Dahlgren S, Teiwik A, Gröndahl K. Long-term evaluation of Astra Tech and Brânemark implants in patients treated with full-arch bridges. Results after 12-15 years. Clin Oral Implants Res 2013;24:1144-51. [CrossRef] google scholar
  3. 3. Arora A, Upadhyaya V, Parashar KR, Malik D. Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy - An in vitro study. J Indian Prosthodont Soc 2019;19:149-58. [CrossRef] google scholar
  4. 4. Bhakta S, Vere J, Calder I, Patel R. Impressions in implant dentistry. Br Dent J 2011;211:361-7. [CrossRef] google scholar
  5. 5. Yokoyama S, Wakabayashi N, Shiota M, Ohyama T. Stress analysis in edentulous mandibular bone supporting implant-retained 1-piece or multiple superstructures. Int J Oral Maxillofac Implants 2005;20:578-83. google scholar
  6. 6. Balamurugan T, Manimaran P. Evaluation of accuracy of direct transfer snapon impression coping closed tray impression technique and direct transfer open tray impression technique: an in vitro study. J Indian Prosthodont Soc 2013;13:226-32. [CrossRef] google scholar
  7. 7. Al Quran FA, Rashdan BA, Zomar AA, Weiner S. Passive fit and accuracy of three dental implant impression techniques. Quintessence Int 2012;43:119-25. google scholar
  8. 8. Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofac Implants 2010;25:506-15. google scholar

Details

Primary Language

English

Subjects

Dentistry

Journal Section

Research Article

Authors

Rohini Rajendran This is me
0000-0003-2278-6553
India

N. Gopi Chander * This is me
0000-0002-2040-4550
India

Kuttae Vishwanathan Anitha This is me
0000-0003-0180-9568
India

Balasubramanian Muthukumar This is me
0000-0002-4022-6456
India

Publication Date

June 28, 2021

Submission Date

January 5, 2020

Acceptance Date

October 16, 2020

Published in Issue

Year 2021 Volume: 55 Number: 2

APA
Rajendran, R., Chander, N. G., Anitha, K. V., & Muthukumar, B. (2021). Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. European Oral Research, 55(2), 54-59. https://doi.org/10.26650/eor.20210110
AMA
1.Rajendran R, Chander NG, Anitha KV, Muthukumar B. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. EOR. 2021;55(2):54-59. doi:10.26650/eor.20210110
Chicago
Rajendran, Rohini, N. Gopi Chander, Kuttae Vishwanathan Anitha, and Balasubramanian Muthukumar. 2021. “Dimensional Accuracy of Vinyl Polyether and Polyvinyl Siloxane Impression Materials in Direct Implant Impression Technique for Multiple Dental Implants”. European Oral Research 55 (2): 54-59. https://doi.org/10.26650/eor.20210110.
EndNote
Rajendran R, Chander NG, Anitha KV, Muthukumar B (June 1, 2021) Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. European Oral Research 55 2 54–59.
IEEE
[1]R. Rajendran, N. G. Chander, K. V. Anitha, and B. Muthukumar, “Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants”, EOR, vol. 55, no. 2, pp. 54–59, June 2021, doi: 10.26650/eor.20210110.
ISNAD
Rajendran, Rohini - Chander, N. Gopi - Anitha, Kuttae Vishwanathan - Muthukumar, Balasubramanian. “Dimensional Accuracy of Vinyl Polyether and Polyvinyl Siloxane Impression Materials in Direct Implant Impression Technique for Multiple Dental Implants”. European Oral Research 55/2 (June 1, 2021): 54-59. https://doi.org/10.26650/eor.20210110.
JAMA
1.Rajendran R, Chander NG, Anitha KV, Muthukumar B. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. EOR. 2021;55:54–59.
MLA
Rajendran, Rohini, et al. “Dimensional Accuracy of Vinyl Polyether and Polyvinyl Siloxane Impression Materials in Direct Implant Impression Technique for Multiple Dental Implants”. European Oral Research, vol. 55, no. 2, June 2021, pp. 54-59, doi:10.26650/eor.20210110.
Vancouver
1.Rohini Rajendran, N. Gopi Chander, Kuttae Vishwanathan Anitha, Balasubramanian Muthukumar. Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants. EOR. 2021 Jun. 1;55(2):54-9. doi:10.26650/eor.20210110