Research Article

A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables

Volume: 5 Number: 5 September 4, 2019
EN

A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables

Abstract

Objectives: The aim of the current study was to compare intraocular pressure (IOP), hemodynamic parameters and throat pain in the use of C-MAC videolaryngoscope and the Macintosh laryngoscope under general anesthesia requiring endotracheal intubation.

Methods: Seventy-eight patients aged 18-65 years, ASA (American Society of Anesthesiologists physical status). I-II, who underwent elective surgery under general anesthesia were scheduled in the study. The groups were allocated as Group M (Macintosh laryngoscope) and Group VL (videolaryngoscope). Standard anesthesia technique was used in both groups. To assess the depth of anesthesia which was kept between 40 and 60, a Bispectral Index Monitor Model 2000 (Aspect Medical Systems, Inc, Newton, MA) was used throughout the study. We recorded hemodynamic variables, oxygen saturation before induction, at the 3rd and at the 10th minutes after intubation. The duration of intubation was recorded as the time from the laryngoscope entering the mouth to removal with end-tidal carbon dioxide on the monitor. IOP was measured before induction, and at the 3rd and 10th minutes after intubation. Inhalation agent was given after intubation. 78 patients were included in the study. We recorded cough after extubation, and postoperative sore throat was evaluated by an anesthesiologist who was blinded to the group allocations at 10 minutes and at 24 hours postoperatively.

Results: There was no significant difference between the groups regarding age (p > 0.05), mean body mass index (p = 0.157), mean ASA (p = 0.475), mean bispectral index values (p = 0.084) and mean operating time (p = 0.068). The mean duration of intubation was determined to be statistically significantly longer in Group M than in Group VL (p = 0.0001). There was no statistically significant difference between the groups regarding Modified Mallampati Score (p = 0.571) and Cormack Lehane Score (p = 0.819). The mean IOP at 3rd minute after intubation was determined to be statistically significantly higher in Group M (p = 0.0001). There was no statistically significant difference between the groups in regarding cough after extubation (p = 0.549), throat pain at 10 minutes (p = 0.662) and at 24 hours postoperatively.

Conclusions: C-MAC videolaryngoscope can be recommended as the first choice in patients with high IOP requiring general anesthesia with endotracheal intubation. 

Keywords

References

  1. [1] Vinayagam S, Dhanger S, Tilak P, Gnanasekar R. C-MAC® video laryngoscope with D-BLADE™ and Frova introducer for awake intubation in a patient with parapharyngeal mass. Saudi J Anaesth 2016;10:471-3.
  2. [2] Griesdale DE, Liu D, McKinney J, Choi PT. Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anaesth 2012;59:41-52.
  3. [3] Cavus E, Thee C, Moeller T, Kieckhaefer J, Doerges V, Wagner K. A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia. BMC Anesthesiol 2011;11:6.
  4. [4] Das B, Samal RK, Ghosh A, Kundu R. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery. Braz J Anesthesiol 2016;66:19-23.
  5. [5] Ahmad N, Zahoor A, Riad W, Al Motowa S. Influence of GlideScope assisted endotracheal intubation on intraocular pressure in ophthalmic patients. Saudi J Anaesth. 2015;9:195-8.
  6. [6] Mahjoubifar M, Boroojeny SB. Hemodynamic changes during orotracheal intubation with the Glidescope and direct laryngoscope. IRCMJ 2010;12:406-8.
  7. [7] Win NN, Kohase H, Yoshikawa F, Wakita R, Takahashi M, Kondo N, et al. Haemodynamic changes and heart rate variability during midazolam-propofol co-induction. Anaesthesia 2007;62:561-8.
  8. [8] Yang JC, Siu TS, Ng KF, Gong Z, Tsui SL, Wong JS. Combined effect of isoflurane and esmolol on sympathetic responses to tracheal intubation. Acta Anaesthesiol Sin 2000;38:123-30.

Details

Primary Language

English

Subjects

Ophthalmology, Anaesthesiology

Journal Section

Research Article

Publication Date

September 4, 2019

Submission Date

April 29, 2018

Acceptance Date

November 1, 2018

Published in Issue

Year 2019 Volume: 5 Number: 5

APA
Özhan Çaparlar, C., Bumin Aydın, G., Sezer, E., Ergil, J., & Şanal Doğan, A. (2019). A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables. The European Research Journal, 5(5), 745-750. https://doi.org/10.18621/eurj.419490
AMA
1.Özhan Çaparlar C, Bumin Aydın G, Sezer E, Ergil J, Şanal Doğan A. A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables. Eur Res J. 2019;5(5):745-750. doi:10.18621/eurj.419490
Chicago
Özhan Çaparlar, Ceyda, Gözde Bumin Aydın, Evginar Sezer, Jülide Ergil, and Aysun Şanal Doğan. 2019. “A Comparison of C-MAC Videolaryngoscope and Macintosh Laryngoscope in Intraocular Pressure Changes, Throat Pain, Intubation Time and Hemodynamic Variables”. The European Research Journal 5 (5): 745-50. https://doi.org/10.18621/eurj.419490.
EndNote
Özhan Çaparlar C, Bumin Aydın G, Sezer E, Ergil J, Şanal Doğan A (September 4, 2019) A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables. The European Research Journal 5 5 745–750.
IEEE
[1]C. Özhan Çaparlar, G. Bumin Aydın, E. Sezer, J. Ergil, and A. Şanal Doğan, “A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables”, Eur Res J, vol. 5, no. 5, pp. 745–750, Sept. 2019, doi: 10.18621/eurj.419490.
ISNAD
Özhan Çaparlar, Ceyda - Bumin Aydın, Gözde - Sezer, Evginar - Ergil, Jülide - Şanal Doğan, Aysun. “A Comparison of C-MAC Videolaryngoscope and Macintosh Laryngoscope in Intraocular Pressure Changes, Throat Pain, Intubation Time and Hemodynamic Variables”. The European Research Journal 5/5 (September 4, 2019): 745-750. https://doi.org/10.18621/eurj.419490.
JAMA
1.Özhan Çaparlar C, Bumin Aydın G, Sezer E, Ergil J, Şanal Doğan A. A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables. Eur Res J. 2019;5:745–750.
MLA
Özhan Çaparlar, Ceyda, et al. “A Comparison of C-MAC Videolaryngoscope and Macintosh Laryngoscope in Intraocular Pressure Changes, Throat Pain, Intubation Time and Hemodynamic Variables”. The European Research Journal, vol. 5, no. 5, Sept. 2019, pp. 745-50, doi:10.18621/eurj.419490.
Vancouver
1.Ceyda Özhan Çaparlar, Gözde Bumin Aydın, Evginar Sezer, Jülide Ergil, Aysun Şanal Doğan. A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables. Eur Res J. 2019 Sep. 4;5(5):745-50. doi:10.18621/eurj.419490

Cited By