Research Article

The effect of teicoplanin coating on osteointegration of titanium screws: a biomechanical and histomorphometric study in a rabbit model

Volume: 6 Number: 5 September 4, 2020
EN

The effect of teicoplanin coating on osteointegration of titanium screws: a biomechanical and histomorphometric study in a rabbit model

Abstract

Objectives: The aim of this experimental animal study was to make a biomechanical and histomorphometric evaluation of the effects of titanium screws covered with teicoplanin, which is wanted to prevent the development of infection, on osteointegration of the screw.

Methods: Twenty New Zealand white rabbits were randomly separated into 2 groups. In Group 1, 2 mini screws with teicoplanin coating were placed in the femoral condyles of the right knee and in Group 2, 2 mini screws with no coating. After 4 weeks, all the animals were sacrificed and prepared for biomechanical and histological examinations.

Results: In the pull-out test, the values of Group 1 were found to be higher and in the removal torque test, the values of Group 2 were higher. No positive correlation was found between the pull-out and removal torque tests (r = 0.88). The bone-implant contact value was found to be similar in both groups (p = 0.132).

Conclusions: The results showed that titanium screws with teicoplanin coating did not interfere with osteointegration process biomechanically andhistomorphometrically by comparison with screws having no coating so that teicoplanincoating can be considered for use in orthopedic devices and joint prosthesis to prevent the development of infection. 

Keywords

References

  1. 1. Bruellhoff K, Fiedler J, Möller M, Groll J, Brenner RE. Surface coating strategies to prevent biofilm formation on implant surfaces. Int J Artif Organs 2010;33:646-53.
  2. 2. Del Pozo L, Patel, R. Infection associated with prosthetic joints. N Engl J Med 2009;361:787-94.
  3. 3. Matthews P, Berendt A, McNally M, Byren I. Diagnosis and management of prosthetic joint infection. BMJ 2009;338: b1773.
  4. 4. ter Boo GJ, Grijpma DW, Moriarty TF, Richards RG, Eglin D. Antimicrobial delivery systems for local infection prophylaxis in orthopedic and trauma surgery. Biomaterials 2015;52:113-25.
  5. 5. Alt V, Bitschnau A, Böhner F, Heerich KE, Magesin E, Sewing A, et al. Effects of gentamicin and gentamicin-RGD coatings on bone ingrowth andbiocompatibility of cementless joint prostheses: an experimental study inrabbits. Acta Biomater 2011;7:1274-80.
  6. 6. Guyer RD, Abitbol JJ, Ohnmeiss DD, Yao C. Evaluating osseointegration into a deeply porous titanium scaffold: a biomechanical comparison with peek and allograft. Spine (Phila Pa 1976) 2016;41:E1146-50.
  7. 7. Lin X, Yang S, Lai K, Yang H, Webster TJ, Yang L. Orthopedic implant biomaterials with both osteogenic and anti-infection capacities and associated in vivo evaluation methods. Nanomedicine 2017;13:123-42.
  8. 8. Eltorai AE, Haglin J, Perera S, Brea BA, Ruttiman R, Garcia DR, et al. Antimicrobial technology in orthopedic and spinal implants. World J Orthop 2016;7:361-9.

Details

Primary Language

English

Subjects

Orthopaedics

Journal Section

Research Article

Publication Date

September 4, 2020

Submission Date

August 2, 2019

Acceptance Date

March 5, 2020

Published in Issue

Year 2020 Volume: 6 Number: 5

AMA
1.Çatalbaş A, Akalın Y, Şahin İG, Çevik N, Özkan Y, Öztürk A. The effect of teicoplanin coating on osteointegration of titanium screws: a biomechanical and histomorphometric study in a rabbit model. Eur Res J. 2020;6(5):401-408. doi:10.18621/eurj.600539

Cited By