A perspective of biometric, visual and refractive outcomes of cataract surgery: a report of an ophthalmologist in compulsory governmental service
Abstract
Objectives: Knowledge of normal values of biometric parameters in cohort and relationships of them is helpful for ophthalmologists who want to achieve successful results. The aim of this study is to define these parameters in the light of experiences of an individual cataract surgeon after her residency program.
Methods: This is a retrospective, register-based study. Preoperative biometric and postoperative refractive data including axial length (AL), mean keratometry (K), anterior chamber depth (ACD), astigmatism, lens thickness (LT) of 310 patients who had cataract surgery were reviewed. Ultrasound and optical biometry were used to evaluate the biometric parameters of the eyes.
Results: 0.5 D of refractive target (RT) was obtained in 52.1% (186 eyes) of eyes, 1.0 D of RT in 82.20% (293 eyes) and 2.0 D of RT in 98.3% (351 eyes). Analyses of visual acuity show that 43.7% and 86.3% of eyes reached 0.00 and 0.30 log MAR or better. Age, ACD, LT, AL, preoperative corrected distance visual acuity, preoperative astigmatism and preoperative K were correlated between each other significantly (p < 0.001). The longer AL was found associated with older age (β = .745, p = 0.003), and lower K (β = -0.327, p < 0.001). A significant association between K value and older age (β = .680, p = .029) and shorter AL (β = -.660, p < 0.001) was seen.
Conclusions: These data show the normative parameters of biometry values for the Turkish population. These results may be helpful in calculating intraocular lens power and evaluating refractive error for young ophthalmologists who have to work with ultrasound biometry in compulsory service.
Keywords
References
- 1. Low SA, Braga-Mele R, Yan DB, El-Defrawy S. Intraoperative complication rates in cataract surgery performed by ophthalmology resident trainees compared to staff surgeons in a Canadian academic center. J Cataract Refract Surg 2018;44:1344-9.
- 2. Seitz B, Langenbucher A. Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg 2000;16:349-61.
- 3. Simsek A. Biometric and intraocular pressure changes after Nd: YAG laser capsulotomy. Eur Res J 2017;3:140-4.
- 4. Krysik K, Lyssek-Boron A, Janiszewska-Bil D, Wylegala E, Dobrowolski D. Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus. Int J Ophthalmol 2019;12:949-53.
- 5. Amritanand A, Simha AR, Baglari R, Roselin J, Michael J, Mahasampath G. Agreement of axial length measurements by three different biometric devices. J Clin Diagn Res 2018;12:NC01-NC04.
- 6. Cartwright NK, Johnston R, Jaycock P, Tole D, Sparrow J. The Cataract National Dataset electronic multicentre audit of 55 567 operations: when should IOLMaster biometric measurements be rechecked? Eye 2010;24:894-900.
- 7. Day A, Donachie P, Sparrow J, Johnston R. The Royal College of Ophthalmologists’ National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications. Eye 2015;29:552-60.
- 8. Narendran N, Jaycock P, Johnston R, Taylor H, Adams M, Tole D et al. The Cataract National Dataset electronic multicentre audit of 55 567 operations: risk stratification for posterior capsule rupture and vitreous loss. Eye 2009;23:31-7.
Details
Primary Language
English
Subjects
Ophthalmology
Journal Section
Research Article
Authors
Publication Date
November 4, 2020
Submission Date
June 16, 2020
Acceptance Date
September 16, 2020
Published in Issue
Year 2020 Volume: 6 Number: 6