Signal transformation (derivative and wavelet) was applied to
UV spectra and ratio spectra to directly quantify spiramycin and
metronidazole in binary mixtures. Linear calibration graphs were
examined for either drug in the concentration range of 6.25 – 25
mg/L with R2 > 0.990. First derivative-transformed (i.e., using
Savitzky-Golay filter) and wavelet-transformed (i.e., using families
such as sym6, haar, db5, bior2.4, rbio2.4, meyr with scaling factor =
256) UV spectrophotometric methods were statistically comparable to
the RP-HPLC reference method (p > 0.05) with regard to accuracy
and precision when assaying spiramycin and metronidazole in their
coated tablets. These analytical methods used only green solvent, and
proved to be time-saving and cost-effective.
UV spectrophotometry derivative transform wavelet transform spiramycin metronidazole coated tablets RP-HPLC
Birincil Dil | İngilizce |
---|---|
Konular | Eczacılık ve İlaç Bilimleri |
Bölüm | Araştırma Makalesi |
Yazarlar | |
Yayımlanma Tarihi | 19 Ekim 2022 |
Gönderilme Tarihi | 1 Şubat 2021 |
Yayımlandığı Sayı | Yıl 2022 Cilt: 47 Sayı: 3 |