The Effect of Nanofluid Usage on Electricity Consumption in Thermoelectric Refrigeration Application: An Experimental Study
Abstract
In this study, the effects of nanofluid use in thermoelectric coolers on electricity consumption were investigated. A water-cooled block was placed on the hot side of the TEC in the designed system and a water-to-air heat exchanger was added to the system to cool the coolant. By adding 1% by mass of three distinct nanoparticles (Al2O3, TiO2 ve SiO2) to the fluid, the temperature differences of the cooler cabinet were tested at three distinct outdoor temperatures (18, 24 and 30 °C). In addition, to measure the performance of the cabinet when loaded, 1 litre of water was left in the cabinet and the tests were repeated. In the case where water without nanoparticle addition, which is the reference case, was used as the coolant, the measurement was made for 1 hour and the final temperature of the cooler cabinet was observed. Then the times to obtain the same cooler cabinet temperature by using various nanoparticles were observed. It has been observed that the temperature of the cooler cabinet drops to the desired temperatures earlier in cases where nanofluid was used compared to cooling with water. For this reason, this study is important in terms of efficient use of energy resources.
Keywords
References
- [1] Y. He, R. Li, Y. Fan, Y. Zheng, and G. Chen, “Study on the performance of a solid-state thermoelectric refrigeration system equipped with ionic wind fans for ultra-quiet operation,” Int. J. Refrig., vol. 130, pp. 441–451, 2021, doi: 10.1016/j.ijrefrig.2021.06.017.
- [2] E. Cuce, T. Guclu, and P. M. Cuce, “Improving thermal performance of thermoelectric coolers (TECs) through a nanofluid driven water to air heat exchanger design: An experimental research,” Energy Convers. Manag., vol. 214, no. April, p. 112893, 2020, doi: 10.1016/j.enconman.2020.112893.
- [3] T. Guclu and E. Cuce, “Thermoelectric Coolers (TECs): From Theory to Practice,” J. Electron. Mater., vol. 48, no. 1, pp. 211–230, 2019, doi: 10.1007/s11664-018-6753-0.
- [4] X. D. Wang, Q. H. Wang, and J. L. Xu, “Performance analysis of two-stage TECs (thermoelectric coolers) using a three-dimensional heat-electricity coupled model,” Energy, vol. 65, pp. 419–429, 2014, doi: 10.1016/j.energy.2013.10.047.
- [5] J. Yu and B. Wang, “Enhancing the maximum coefficient of performance of thermoelectric cooling modules using internally cascaded thermoelectric couples,” Int. J. Refrig., vol. 32, no. 1, pp. 32–39, 2009, doi: 10.1016/j.ijrefrig.2008.08.006.
- [6] R. Chein and Y. Chen, “Performances of thermoelectric cooler integrated with microchannel heat sinks,” Int. J. Refrig., vol. 28, no. 6, pp. 828–839, 2005, doi: 10.1016/j.ijrefrig.2005.02.001.
- [7] L. Zhu and J. Yu, “Optimization of heat sink of thermoelectric cooler using entropy generation analysis,” Int. J. Therm. Sci., vol. 118, pp. 168–175, 2017, doi: 10.1016/j.ijthermalsci.2017.04.015.
- [8] L. Zhu, H. Tan, and J. Yu, “Analysis on optimal heat exchanger size of thermoelectric cooler for electronic cooling applications,” Energy Convers. Manag., vol. 76, pp. 685–690, 2013, doi: 10.1016/j.enconman.2013.08.014. [9] H. Sadighi Dizaji, S. Jafarmadar, S. Khalilarya, and A. Moosavi, “An exhaustive experimental study of a novel air-water based thermoelectric cooling unit,” Appl. Energy, vol. 181, pp. 357–366, 2016, doi: 10.1016/j.apenergy.2016.08.074.
Details
Primary Language
English
Subjects
Mechanical Engineering
Journal Section
Research Article
Publication Date
September 1, 2022
Submission Date
February 7, 2022
Acceptance Date
May 19, 2022
Published in Issue
Year 2022 Volume: 8 Number: 2