Comparison of Experimental and Monte Carlo Efficiencies of 0.5g/cc Epoxy Matrix Marinelli Source with Multiple Radioactive Nuclides
Abstract
Keywords
References
- Ahmed, A. S., Capello, K., Chiang, A., Cardenas-Mendez, E., & Kramer, G. H. (2009). Optimization of geometric parameters for Marinelli beaker to maximize the detection efficiency of an HPGe detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 610(3), 718-723. doi:10.1016/j.nima.2009.09.020
- Azli, T., & Chaoui, Z.-E.-A. (2015). Performance Revaluation of a N-Type Coaxial HPGe Detector with Front Edges Crystal Using MCNPX. Applied Radiation and Isotopes. 97, 106-112. doi:10.1016/j.apradiso.2014.12.027
- Bölükdemir, M. H., Uyar, E., Aksoy, G., Ünlü, H., Dikmen, H., & Özgür, M. (2021). Investigation of Shape Effects and Dead Layer Thicknesses of a Coaxial HPGe Crystal on Detector Efficiency by Using PHITS Monte Carlo Simulation. Radiation Physics and Chemistry, 189, 109746. doi:10.1016/j.radphyschem.2021.109746
- Britton, R., Burnett, J., Davies, A., & Regan, P. H. (2013). Determining the Efficiency of a Broad-Energy HPGe Detector Using Monte Carlo Simulations. Journal of Radioanalytical and Nuclear Chemistry, 295(3), 2035-2041. doi:10.1007/s10967-012-2203-2
- Gilmore, G. (2008). Practical Gamma-Ray Spectrometry: Second Edition. John Wiley and Sons.
- Harb, S., Salahel Din, K., & Abbady, A. (2008, February 19-23). Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples. In: Proceedings of the 3rd Environmental Physics Conference, (pp. 207-218), Aswan, Egypt.
- Huy, N. Q., Binh, D. Q., & An, V. X. (2007). Study on the Increase of Inactive Germanium Layer in a High-Purity Germanium Detector after a Long Time Operation Applying MCNP Code. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 573(3), 384-388. doi:10.1016/j.nima.2006.12.048
- Huy, N. Q. (2011). Dead-Layer Thickness Effect for Gamma Spectra Measured in an HPGe p-Type Detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 641(1), 101-104. doi:10.1016/j.nima.2011.02.097
Details
Primary Language
English
Subjects
-
Journal Section
Research Article
Authors
Gülper Aksoy
0000-0003-4730-0935
Türkiye
Hasan Ünlü
0000-0003-2006-6165
Türkiye
Nilgün Orhan
0000-0002-5219-6899
Türkiye
Publication Date
December 31, 2022
Submission Date
May 21, 2022
Acceptance Date
September 5, 2022
Published in Issue
Year 2022 Volume: 9 Number: 4