Abstract

In this study, drop form flow examinations, which form the basis of IV applications used for therapeutic purposes, were performed. Fluid Intravenous (IV) is the practice of administering fluids into a vein. In IV applications, flow must be monitored in order to follow and control the treatment process. For this purpose, the fluid can be converted into drop form with a simple mechanism and the flow rate and volume data can be calculated by the drop counting method. Examining drop form flow processes and analyzing microdrops correctly increases the accuracy in calculating flow data and, most importantly, increases the quality of treatment in IV applications. In the scope of this study, the formation processes of microdrops and the affecting parameters were analyzed. Along with microdrop analysis, error evaluation of the drop counting method and evaluation of measurement techniques were carried out to ensure a healthy and accurate measurement process. System tests and verification were carried out with optical systems, one of the measurement techniques. As a result, this study was carried out on the importance of monitoring systems and measurement parameters in IV applications.

Keywords

References

  1. 1. Kim, U. R., Peterfreund, R. A., Lovich, M. A. (2017), Drug infusion systems: Technologies, performance, and pitfalls. In Anesthesia and Analgesia (Vol. 124, Issue 5, pp. 1493–1505). Lippincott Williams and Wilkins.
  2. 2. Flack, F. C., Whyte, T. D. (1975), Variations of drop size in disposable administration sets used for intravenous infusion. In J. clin. Path (Vol. 28).
  3. 3. Stoneham, M. D. (1995), An evaluation of methods of increasing the flow rate of i.v. fluid administration. British Journal of Anaesthesia, 75(3), 361–365.
  4. 4. Singh, S., Randle, L. V., Callaghan, P. T., Watson, C. J. E., Callaghan, C. J. (2013), Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model. Journal of Transplantation, (2013), 1-6, (2013).
  5. 5. Tolman, R. C. (1949), The effect of droplet size on surface tension. The Journal of Chemical Physics, 17(3), 333–337.
  6. 6. La Cour D. (1965), Drop size in disposable sets for intravenous infusion, Acta Anaesthesiol Scand, 9, 145-154.
  7. 7. Hillman, M. R. (1989), The prediction of drop size from intravenous infusion controllers, Journal of Medical Engineering & Technology, 13(3), 166-176.
  8. 8. Murphy, R. S., Wilcox, S. J. (2009), High risk infusions - Accuracy compromised by changes in patient venous pressure. Journal of Medical Engineering and Technology, 33(6), 470–474.

Details

Primary Language

English

Subjects

Control Engineering, Mechanical Engineering (Other)

Journal Section

Research Article

Publication Date

June 30, 2024

Submission Date

March 5, 2024

Acceptance Date

June 5, 2024

Published in Issue

Year 2024 Volume: 11 Number: 2

APA
Ceylan, H., Karabaş, O., & Yiğit, K. S. (2024). Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems. Hittite Journal of Science and Engineering, 11(2), 69-75. https://doi.org/10.17350/HJSE19030000333
AMA
1.Ceylan H, Karabaş O, Yiğit KS. Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems. Hittite J Sci Eng. 2024;11(2):69-75. doi:10.17350/HJSE19030000333
Chicago
Ceylan, Halid, Ogan Karabaş, and Kadri Süleyman Yiğit. 2024. “Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems”. Hittite Journal of Science and Engineering 11 (2): 69-75. https://doi.org/10.17350/HJSE19030000333.
EndNote
Ceylan H, Karabaş O, Yiğit KS (June 1, 2024) Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems. Hittite Journal of Science and Engineering 11 2 69–75.
IEEE
[1]H. Ceylan, O. Karabaş, and K. S. Yiğit, “Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems”, Hittite J Sci Eng, vol. 11, no. 2, pp. 69–75, June 2024, doi: 10.17350/HJSE19030000333.
ISNAD
Ceylan, Halid - Karabaş, Ogan - Yiğit, Kadri Süleyman. “Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems”. Hittite Journal of Science and Engineering 11/2 (June 1, 2024): 69-75. https://doi.org/10.17350/HJSE19030000333.
JAMA
1.Ceylan H, Karabaş O, Yiğit KS. Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems. Hittite J Sci Eng. 2024;11:69–75.
MLA
Ceylan, Halid, et al. “Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems”. Hittite Journal of Science and Engineering, vol. 11, no. 2, June 2024, pp. 69-75, doi:10.17350/HJSE19030000333.
Vancouver
1.Halid Ceylan, Ogan Karabaş, Kadri Süleyman Yiğit. Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems. Hittite J Sci Eng. 2024 Jun. 1;11(2):69-75. doi:10.17350/HJSE19030000333

Hittite Journal of Science and Engineering is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY NC).