Examining the risk of flotation in structures
Abstract
Lately, an increase in the number of floors in structures that have been built on valuable land can be noticed. While building these structures, a retaining wall is created, which is necessary for a safe foundation, yet this also causes the formation of a closed pool-like area. If the excavation site during construction is filled with water due to various reasons, basement floors, which form closed volume, may move upwards. The same problem may also be experienced in all elements that are underground in flood susceptible areas. Unfortunately, engineers often overlook this potential problem while focusing on the completed structure weight. This flotation damage should not be confused with liquefaction of ground that occurs as a result of unexpected movements in the structure due to the loss of the bearing capacity of the ground. The necessary calculations to avoid this risk are only conditioned for port and coastal structures in national standards and codes. Hence, this study aims to demonstrate the conditions leading to flotation in structures and necessary precautions to avoid them.
Keywords
References
- 1. Nakamura, S., Japan monitoring of buoyancy effects to structures by tsunami water after heavy seismic shocks, in PIERS Proceedings 2015: Prague, Czech Republic. p. 1058-1060.
- 2. Kabeyasawa, T., Y. Okuda, A. Fukai, H. Fukuyama, H. Kato, T. Ishihara, et al., Evaluation of lateral and buoyant forces on reinforced concrete buildings by the tsunami of the 2011 east japan earthquake, in WCEE2012: Lisboa.
- 3. Yeh, H., AR. Barbosa, H. Ko, and J. Cawley, Tsunami loadings on structures review and analysis, in International Conference on Coastal Engineering ICCE2014: Seoul, Korea. p. 1-13.
- 4. Japan Times. [cited 2017 27 July]; Available from http://www.japantimes.co.jp/tag/national-police-agency.
- 5. Web Archive. [cited 2017 13 May]; Available from: http://web.archive.org/web/20131031173818/http://earthquake.usgs.gov:80/earthquakes/eqinthenews/2011/usc0001xgp
- 6. Bikce, M., Örnek, M. and Cansız, Ö.F. & Quot; A case study & quot ;, Engineering Failure Analysis, 92: p. 553-565, 2018.
- 7. FEMA. [cited 2017 13 May]; Available from: https://www.fema.gov/media-library-data/643d07bceee 8ade17eef8e11cf7a2abb/P-936_sec2_508.pdf
- 8. FEMA. Design manual for retrofitting flood-prone residential structures, in Federal Emergency Management Agency 1986: ABD. p. 114.
Details
Primary Language
English
Subjects
-
Journal Section
Research Article
Authors
Murat Bikçe
*
Türkiye
Publication Date
August 15, 2018
Submission Date
March 9, 2018
Acceptance Date
May 11, 2018
Published in Issue
Year 2018 Volume: 2 Number: 2