Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2019, , 44 - 48, 30.06.2019
https://doi.org/10.18100/ijamec.569835

Öz

Kaynakça

  • Famaey, N., et al., Acoustical analysis of mechanical heart valve sounds for early detection of malfunction. Medical Engineering & Physics, 2010. 32(8): p. 934-939.
  • Altunkaya, S., et al., Statistically evaluation of mechanical heart valve thrombosis using heart sounds, in Lecture Notes in Engineering and Computer Science: Proceedings of The World Congress on Engineering. 2010: London, U.K. p. 704-708.
  • Dominik, J.Z., P., Heart valve surgery an illustrated guide. 2010, Berlin Heidelberg: Springer-Verlag.
  • Caceres-Loriga, F.M., et al., Prosthetic heart valve thrombosis: Pathogenesis, diagnosis and management. International Journal of Cardiology, 2006. 110(1): p. 1-6.
  • Roscitano, A., et al., Acute dysfunction from thrombosis of mechanical mitral valve prosthesis. Braz. J. Cardiovasc. Surg, 2005: p. 88-90.
  • Roudaut, R., et al., Fibrinolysis of mechanical prosthetic valve thrombosis - A single-center study of 127 cases. Journal of the American College of Cardiology, 2003. 41(4): p. 653-658.
  • Schlitt, A., et al., Effects of combined therapy of clopidogrel and aspirin in preventing thrombus formation on mechanical heart valves in an ex vivo rabbit model. Thrombosis Research, 2002. 107(1-2): p. 39-43.
  • Hylen, J.C., et al., Sound spectrographic diagnosis of aortic ball variance. Circulation, 1969. 39(6): p. 849-58.
  • Koymen, H., B.K. Altay, and Y.Z. Ider, A Study of Prosthetic Heart-Valve Sounds. Ieee Transactions on Biomedical Engineering, 1987. 34(11): p. 853-863.
  • Baykal, A., Y.Z. Ider, and H. Koymen, Distribution of Aortic Mechanical Prosthetic Valve Closure Sound Model Parameters on the Surface of the Chest. Ieee Transactions on Biomedical Engineering, 1995. 42(4): p. 358-370.
  • Sava, H.P. and J.T.E. McDonnell, Spectral composition of heart sounds before and after mechanical heart valve implantation using a modified forward-backward Prony's method. Ieee Transactions on Biomedical Engineering, 1996. 43(7): p. 734-742.
  • Kim, S.H., et al., Spectral analysis of heart valve sound for detection of prosthetic heart valve diseases. Yonsei Medical Journal, 1998. 39(4): p. 302-308.
  • Fritzsche, D., et al., Digital frequency analysis of valve sound phenomena in patients after prosthetic valve surgery: Its capability as a true home monitoring of valve function. Journal of Heart Valve Disease, 2005. 14(5): p. 657-663.
  • Sugiki, H., et al., Bileaflet mechanical valve sound analysis using a continuous wavelet transform. Journal of Artificial Organs, 2006. 9(1): p. 42-49.
  • Sugiki, H., et al., Wavelet analysis of bileaflet mechanical valve sounds. Journal of Artificial Organs, 2007. 10(1): p. 16-21.
  • Fritzsche, D., et al., Early detection of mechanical valve dysfunction using a new home monitoring device. Annals of Thoracic Surgery, 2007. 83(2): p. 542-548.
  • Sugiki, H., et al., Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve. Journal of Artificial Organs, 2008. 11(1): p. 29-37.
  • Zhang, D., et al. Detection of Mechanical Prosthetic Heart Valve Dysfunction Using Spectrum Estimation and Time-Scale Techniques. in IEEE Pacific-Asia Workshop on Computational Intelligence and Industrial Application. 2008. Wuhan.
  • Romata, C., et al., Comparative classification of thrombotic formations on bileaflet mechanical heart valves by phonographic analysis. Journal of Artificial Organs, 2011. 14(2): p. 100-111.
  • Zhang, D., et al., Noninvasive detection of mechanical prosthetic heart valve disorder. Computers in Biology and Medicine, 2012. 42(8): p. 785-792.
  • Zhang, D. and M. Du. Diagnosis of prosthetic heart valve using locality preserving kernel fisher discriminant analysis and local discriminant bases. in 2015 8th International Conference on Biomedical Engineering and Informatics (BMEI). 2015. IEEE.
  • Tosoni, S., et al., Phonographic detection of mechanical heart valve thrombosis. Journal of Artificial Organs, 2017. 20(4): p. 394-398.
  • Altunkaya, S., et al., Comparison of first and second heart sounds after mechanical heart valve replacement. Computer Methods in Biomechanics and Biomedical Engineering, 2013. 16(4): p. 368-380.
  • Cortes, C. and V. Vapnik, Support-vector networks. Machine learning, 1995. 20(3): p. 273-297.
  • Yilmaz, N., O. Inan, and M.S. Uzer, A New Data Preparation Method Based on Clustering Algorithms for Diagnosis Systems of Heart and Diabetes Diseases. Journal of Medical Systems, 2014. 38(5).
  • Ivanciuc, O., Reviews in Computational Chemistry. Vol. 23. 2007: John Wiley & Sons, Inc. 291-400.
  • Polat, K. and S. Gunes, Hepatitis disease diagnosis using a new hybrid system based on feature selection (FS) and artificial immune recognition system with fuzzy resource allocation. Digital Signal Processing, 2006. 16(6): p. 889-901.
  • Reynolds, K.J. and R.O. Stephen, Acoustic analysis of the closing sounds of implanted prosthetic heart valves. J Acoust Soc Am, 1995. 98(1): p. 69-77.
  • Bagno, A., et al., Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis. Journal of Artificial Organs, 2009. 12(3): p. 172-181.

Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine

Yıl 2019, , 44 - 48, 30.06.2019
https://doi.org/10.18100/ijamec.569835

Öz

Thrombosis on the valve that prevents the movement of mechanical heart
valves is a fatal disease requiring urgent intervention. Thrombosis is detected
by echocardiographic findings and/or CT images. In this study, it has been
tried to determine the formation of thrombosis by listening method which has
been used for controlling the functionality of the heart valves for years. For
this firstly heart sounds of patients with thrombosis and normal mechanical
heart valves were recorded. Then the first and second heart sounds (S1 and S2)
were separated from the recorded sounds. After the frequency spectrum of S1 and
S2 were found using autoregressive spectrum estimation methods, six features
were obtained regarding the frequency components. Then the features obtained
are classified by support vector machine methods. The accuracy value was found
to be 100% by using the 3 fold cross-validation. The average accuracy is 95.18%
as a result of running the classifier 500 times using 3 fold-cross validation.

Kaynakça

  • Famaey, N., et al., Acoustical analysis of mechanical heart valve sounds for early detection of malfunction. Medical Engineering & Physics, 2010. 32(8): p. 934-939.
  • Altunkaya, S., et al., Statistically evaluation of mechanical heart valve thrombosis using heart sounds, in Lecture Notes in Engineering and Computer Science: Proceedings of The World Congress on Engineering. 2010: London, U.K. p. 704-708.
  • Dominik, J.Z., P., Heart valve surgery an illustrated guide. 2010, Berlin Heidelberg: Springer-Verlag.
  • Caceres-Loriga, F.M., et al., Prosthetic heart valve thrombosis: Pathogenesis, diagnosis and management. International Journal of Cardiology, 2006. 110(1): p. 1-6.
  • Roscitano, A., et al., Acute dysfunction from thrombosis of mechanical mitral valve prosthesis. Braz. J. Cardiovasc. Surg, 2005: p. 88-90.
  • Roudaut, R., et al., Fibrinolysis of mechanical prosthetic valve thrombosis - A single-center study of 127 cases. Journal of the American College of Cardiology, 2003. 41(4): p. 653-658.
  • Schlitt, A., et al., Effects of combined therapy of clopidogrel and aspirin in preventing thrombus formation on mechanical heart valves in an ex vivo rabbit model. Thrombosis Research, 2002. 107(1-2): p. 39-43.
  • Hylen, J.C., et al., Sound spectrographic diagnosis of aortic ball variance. Circulation, 1969. 39(6): p. 849-58.
  • Koymen, H., B.K. Altay, and Y.Z. Ider, A Study of Prosthetic Heart-Valve Sounds. Ieee Transactions on Biomedical Engineering, 1987. 34(11): p. 853-863.
  • Baykal, A., Y.Z. Ider, and H. Koymen, Distribution of Aortic Mechanical Prosthetic Valve Closure Sound Model Parameters on the Surface of the Chest. Ieee Transactions on Biomedical Engineering, 1995. 42(4): p. 358-370.
  • Sava, H.P. and J.T.E. McDonnell, Spectral composition of heart sounds before and after mechanical heart valve implantation using a modified forward-backward Prony's method. Ieee Transactions on Biomedical Engineering, 1996. 43(7): p. 734-742.
  • Kim, S.H., et al., Spectral analysis of heart valve sound for detection of prosthetic heart valve diseases. Yonsei Medical Journal, 1998. 39(4): p. 302-308.
  • Fritzsche, D., et al., Digital frequency analysis of valve sound phenomena in patients after prosthetic valve surgery: Its capability as a true home monitoring of valve function. Journal of Heart Valve Disease, 2005. 14(5): p. 657-663.
  • Sugiki, H., et al., Bileaflet mechanical valve sound analysis using a continuous wavelet transform. Journal of Artificial Organs, 2006. 9(1): p. 42-49.
  • Sugiki, H., et al., Wavelet analysis of bileaflet mechanical valve sounds. Journal of Artificial Organs, 2007. 10(1): p. 16-21.
  • Fritzsche, D., et al., Early detection of mechanical valve dysfunction using a new home monitoring device. Annals of Thoracic Surgery, 2007. 83(2): p. 542-548.
  • Sugiki, H., et al., Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve. Journal of Artificial Organs, 2008. 11(1): p. 29-37.
  • Zhang, D., et al. Detection of Mechanical Prosthetic Heart Valve Dysfunction Using Spectrum Estimation and Time-Scale Techniques. in IEEE Pacific-Asia Workshop on Computational Intelligence and Industrial Application. 2008. Wuhan.
  • Romata, C., et al., Comparative classification of thrombotic formations on bileaflet mechanical heart valves by phonographic analysis. Journal of Artificial Organs, 2011. 14(2): p. 100-111.
  • Zhang, D., et al., Noninvasive detection of mechanical prosthetic heart valve disorder. Computers in Biology and Medicine, 2012. 42(8): p. 785-792.
  • Zhang, D. and M. Du. Diagnosis of prosthetic heart valve using locality preserving kernel fisher discriminant analysis and local discriminant bases. in 2015 8th International Conference on Biomedical Engineering and Informatics (BMEI). 2015. IEEE.
  • Tosoni, S., et al., Phonographic detection of mechanical heart valve thrombosis. Journal of Artificial Organs, 2017. 20(4): p. 394-398.
  • Altunkaya, S., et al., Comparison of first and second heart sounds after mechanical heart valve replacement. Computer Methods in Biomechanics and Biomedical Engineering, 2013. 16(4): p. 368-380.
  • Cortes, C. and V. Vapnik, Support-vector networks. Machine learning, 1995. 20(3): p. 273-297.
  • Yilmaz, N., O. Inan, and M.S. Uzer, A New Data Preparation Method Based on Clustering Algorithms for Diagnosis Systems of Heart and Diabetes Diseases. Journal of Medical Systems, 2014. 38(5).
  • Ivanciuc, O., Reviews in Computational Chemistry. Vol. 23. 2007: John Wiley & Sons, Inc. 291-400.
  • Polat, K. and S. Gunes, Hepatitis disease diagnosis using a new hybrid system based on feature selection (FS) and artificial immune recognition system with fuzzy resource allocation. Digital Signal Processing, 2006. 16(6): p. 889-901.
  • Reynolds, K.J. and R.O. Stephen, Acoustic analysis of the closing sounds of implanted prosthetic heart valves. J Acoust Soc Am, 1995. 98(1): p. 69-77.
  • Bagno, A., et al., Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis. Journal of Artificial Organs, 2009. 12(3): p. 172-181.
Toplam 29 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Research Article
Yazarlar

Sabri Altunkaya Bu kişi benim 0000-0002-0853-0095

Onur İnan 0000-0003-4573-7025

Yayımlanma Tarihi 30 Haziran 2019
Yayımlandığı Sayı Yıl 2019

Kaynak Göster

APA Altunkaya, S., & İnan, O. (2019). Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine. International Journal of Applied Mathematics Electronics and Computers, 7(2), 44-48. https://doi.org/10.18100/ijamec.569835
AMA Altunkaya S, İnan O. Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine. International Journal of Applied Mathematics Electronics and Computers. Haziran 2019;7(2):44-48. doi:10.18100/ijamec.569835
Chicago Altunkaya, Sabri, ve Onur İnan. “Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine”. International Journal of Applied Mathematics Electronics and Computers 7, sy. 2 (Haziran 2019): 44-48. https://doi.org/10.18100/ijamec.569835.
EndNote Altunkaya S, İnan O (01 Haziran 2019) Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine. International Journal of Applied Mathematics Electronics and Computers 7 2 44–48.
IEEE S. Altunkaya ve O. İnan, “Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine”, International Journal of Applied Mathematics Electronics and Computers, c. 7, sy. 2, ss. 44–48, 2019, doi: 10.18100/ijamec.569835.
ISNAD Altunkaya, Sabri - İnan, Onur. “Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine”. International Journal of Applied Mathematics Electronics and Computers 7/2 (Haziran 2019), 44-48. https://doi.org/10.18100/ijamec.569835.
JAMA Altunkaya S, İnan O. Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine. International Journal of Applied Mathematics Electronics and Computers. 2019;7:44–48.
MLA Altunkaya, Sabri ve Onur İnan. “Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine”. International Journal of Applied Mathematics Electronics and Computers, c. 7, sy. 2, 2019, ss. 44-48, doi:10.18100/ijamec.569835.
Vancouver Altunkaya S, İnan O. Detection of Mechanical Heart Valve Thrombosis Using Support Vector Machine. International Journal of Applied Mathematics Electronics and Computers. 2019;7(2):44-8.